Inspections for the day of: Friday, July 13, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03274 Final7/11/20187/13/20187/13/2018 4:20:10 PMPPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC17-04433 Rough-in7/12/20187/13/20187/13/2018 3:42:31 PMPFAIL
2nd layer fire wrap - John Phone #: ###-#### - Need to complete banding on 2nd layer, Need to complete furnace flue in kitchen, Need to address low air flows on balance report.
MEC18-03353 Final7/13/20187/13/20187/13/2018 3:11:07 PMPNR
Please call on way: Dave ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
MEC18-01603 Final7/12/20187/13/20187/13/2018 2:30:14 PMPPASS
PLEASE CALL CONTRACTOR NATE @ # LISTED WHEN EN ROUTE FOR FINAL INSPECTION. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
MEC18-01771 Final7/13/20187/13/20187/13/2018 2:08:02 PMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC18-01777 Final7/13/20187/13/20187/13/2018 2:07:51 PMPPASS
Field Super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC18-01768 Final7/13/20187/13/20187/13/2018 1:58:13 PMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC18-02283 Rough-in7/13/20187/13/20187/13/2018 1:38:00 PMPPART
2nd floor cover please Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover walls & TGi's in units 201, 202, 203, 204, 206, 207, 208, 217, 218, 219
MEC18-03287 Final7/11/20187/13/20187/13/2018 12:58:48 PMPCANC
Please call on way: Tyrel ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
MEC18-03355 Rough-in7/12/20187/13/20187/13/2018 11:48:29 AMAPART
Cover inspection Phone #: ###-#### Inspection requested via web by RaChelle Frisbee - Space 427 not ready, okay to cover space 424
MIS18-00257 MEC-Conference7/11/20187/13/20187/13/2018 11:24:56 AMADONE
Homeowner complaint about ductwork installed improperly from a furnace and duct work change out last fall. The homeowner got ahold of Jack and requested we come by and take a look at the duct work. She states she has been having issues with air flow and being able to cool her house ever since the work was completed last fall by 1A Heating and Cooling. She had C & B heating and cooling come out and take a look at it for her. They told her the ducts were undersized, some cans not hooked up, ducts not strapped up and ducts not insulated properly. Bill and I called Gary with C & B and he told us the same thing. Jack and I went out today to take a look at it for her. She indicated that C & B had fixed the unconnected duct to the return grill but at her request left the other stuff for us to take a look at. We went up in the attic and inspected the duct work and found the ducts to be supported properly, all the ducts were connected to the cans, however I could see where it looked like the flex had come loose on the return and was reconnected and taped to the duct (presumably by C & B), there was 2 spots were the duct insulation was not properly installed and bare metal was showing. As for the undersized duct work the contractor would need to do an ACCA report for the house to see if the ducts are adequate or undersized. The City of Boise does not require this to be done on a retro-fit system change out. For the most part the besides the duct insulation the biggest issue I saw was poor workmanship but installed per the minimum standards of the code. I asked the homeowner if she would like me to get ahold of 1A heating and cooling and ask him to come back and fix the duct insulation and adjust the return duct to try and get better air flow. She indicated she would have to think about and let me know, because she wasn't sure she wanted to let him come back into her house. I ask her to give me a call and let me know if she wanted me to contact him. In addition I did let her know that besides the duct issue's the other problem she is having with trying to get her house to cool properly is she doesn't ahve any insulation in the attic. She had removed it all and hasn't replaced it yet. I told her that any air conditioning system would struggle to over come the lack of insulation in the attic. She said she is working on getting it replaced.
MEC18-03134 Final7/12/20187/13/20187/13/2018 10:19:20 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC18-03088 Final7/12/20187/13/20187/13/2018 9:57:16 AMAPASS
Please call the Owner, Jeff at ###-#### with a 30 minute heads up arrival time. Thank you! Phone #: ###-#### Inspection requested via web by David or K Cole
MEC17-04433 Rough-in7/12/20187/13/20187/13/2018 8:06:22 AMAPASS
1st layer fire wrap - John Phone #: ###-#### - 1st layer fire wrap on the discharge side of the fans okay