MEC19-04373
| Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 3:53:06 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sheldon Lebow
|
MEC19-04349
| Final | 10/1/2019 | 10/2/2019 | 10/2/2019 3:17:20 PM | P | PASS |
|
|
Flue Pressure as well. Please inspect PM and call Dave on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 5lb,furnace -
|
MEC19-02858
| Final | 10/1/2019 | 10/2/2019 | 10/2/2019 2:54:27 PM | P | PASS |
|
|
Mechanical Gas Fireplace Final Inspection. Manual is in kitchen drawer right of stove. Garage Code: 3283 Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC19-04265
| Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 2:31:34 PM | P | PASS |
|
|
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC19-04360
| Pressure Test | 10/1/2019 | 10/2/2019 | 10/2/2019 2:14:53 PM | P | FAIL |
|
|
apt #3-303 Contact Office at ###-#### or Shawn Miller-Cascade Refrigeration ###-#### Phone #: ###-#### Inspection requested via web by shawn miller - not holding pressure -
|
MEC19-02371
| Final | 10/2/2019 | 10/2/2019 | 10/2/2019 2:01:22 PM | P | PASS |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC19-02002
| Final | 10/2/2019 | 10/2/2019 | 10/2/2019 1:32:23 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Teresa Costello - no access, condencer needs locking caps -
|
MEC19-02267
| Final | 10/2/2019 | 10/2/2019 | 10/2/2019 1:16:37 PM | P | FAIL |
|
|
should be open access, if not please contact casey for access info at ###-#### Phone #: ###-#### Inspection requested via web by Amanda Casper - 2nd condensate drain not run -
|
MEC19-02651
| Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 11:34:23 AM | A | PASS |
|
|
Please call Fernando at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum - 12" supply and return chiller piping from mechanicalroom to out side the building, full length pipes no joints -
|
MEC19-03870
| Rough-in | 9/27/2019 | 10/2/2019 | 10/2/2019 11:22:29 AM | A | PASS |
|
|
Open access to the property Phone #: ###-#### Inspection requested via web by Amanda Casper
|
MEC19-03870
| Pressure Test | 9/27/2019 | 10/2/2019 | 10/2/2019 11:22:18 AM | A | PART |
|
|
Open access to the property Phone #: ###-#### Inspection requested via web by Amanda Casper - 20lb in the building - - need flue pressure test when you call in out door gas piping -
|
MEC19-01916
| Final | 10/1/2019 | 10/2/2019 | 10/2/2019 11:10:11 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC19-04332
| Final | 9/30/2019 | 10/2/2019 | 10/2/2019 10:45:41 AM | A | FAIL |
|
|
Joe should be home, give a call ###-####, furnace in basement, ac on side of garage Phone #: ###-#### Inspection requested via web by John Bertram - need to witness flue pressure test - - condencer needs locking caps -
|
MEC18-04797
| Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 10:20:08 AM | A | PASS |
|
|
R/I inspection on room 406 range hood. Please call Curt at ###-#### prior to arrival on-site. Phone #: ###-#### Inspection requested via web by Commercial Coordinator
|
MEC18-04797
| DOC - Permit Finaled | 10/2/2019 | 10/2/2019 | 10/2/2019 10:20:00 AM | P | PASS |
|
|
|
MEC19-01661
| Pressure Test | 10/1/2019 | 10/2/2019 | 10/2/2019 9:55:45 AM | A | PASS |
|
|
if questions call Glen @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann - 60lb full building, regulators and final connections remain. -
|
MEC19-04343
| Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 9:54:57 AM | A | PASS |
|
|
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC19-02659
| Final | 10/1/2019 | 10/2/2019 | 10/2/2019 9:54:45 AM | A | PASS |
|
|
MIKE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC19-04280
| Pressure Test | 10/1/2019 | 10/2/2019 | 10/2/2019 9:09:36 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino - 20lb -
|
MEC19-04280
| Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 9:09:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino
|
MEC19-04143
| Pressure Test | 10/1/2019 | 10/2/2019 | 10/2/2019 9:09:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino - 20lb -
|
MEC19-04143
| Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 9:08:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino
|
MEC19-04142
| Pressure Test | 10/1/2019 | 10/2/2019 | 10/2/2019 9:08:30 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino - 20lb -
|
MEC19-04142
| Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 9:08:12 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino
|
MEC19-01961
| Final | 10/2/2019 | 10/2/2019 | 10/2/2019 9:07:57 AM | A | FAIL |
|
|
4908 garage code. Phone #: ###-#### Inspection requested via web by Aaron Toomey - need locking caps on condencer, need protection post infront of water heaters -
|
MEC18-02772
| Mec-Aging Inspection | 10/2/2019 | 10/2/2019 | 10/2/2019 7:41:03 AM | | CANC |
|
|
|
MEC18-02772
| DOC - Permit Expired | 10/2/2019 | 10/2/2019 | 10/2/2019 7:40:57 AM | P | PASS |
|
|
|