Inspections for the day of: Friday, October 25, 2019.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04807 Final10/23/201910/25/201910/25/2019 3:38:36 PMPPASS
Field super: Chard Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC19-04079 Rough-in10/25/201910/25/201910/25/2019 2:51:40 PMPPASS
BILL ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC19-03991 Final10/25/201910/25/201910/25/2019 2:50:39 PMPPASS
BILL ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC19-04030 Rough-in10/25/201910/25/201910/25/2019 2:42:23 PMPPASS
Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC19-04030 Pressure Test10/25/201910/25/201910/25/2019 2:42:11 PMPPASS
Phone #: ###-#### Inspection requested via web by Lisa Whitney
- 20lb -
MEC19-04832 Final10/25/201910/25/201910/25/2019 2:26:15 PMPPASS
Phone #: ###-#### Inspection requested via web by Sheldon Lebow
MEC19-02682 Final10/25/201910/25/201910/25/2019 2:14:53 PMPPASS
MEC19-04487 Rough-in10/25/201910/25/201910/25/2019 1:48:58 PMPFAIL
Please text or call 1hr. prior to inspection to ensure the building is open. Thank you. Richard 208.412.6713 Phone #: ###-#### Inspection requested via web by Richard Cusimano
- condensate piping needs more nail plates -
- some condensate fittings not glued -
- need barrbed fitting from flex tubing to 3/4 " pvc -
- need flue pressure test -
- dryer vent in basement isnt run to outside -
- dryer vent 1st floor needs tobe rough in -
- gas piping in crawl needs tobe supported -
- if gas piping is new it will need a pressure test -
MEC19-03328 Final10/24/201910/25/201910/25/2019 11:08:42 AMAPASS
RON ###-#### - SCREEN ON BACK ORDER Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC19-03329 Final10/24/201910/25/201910/25/2019 11:08:32 AMAPASS
RON ###-#### - SCREEN ON BACK ORDER
Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC19-04518 Rough-in10/25/201910/25/201910/25/2019 10:43:13 AMAPASS
Cover inspection for rooms 2, 4 and 6. Please contact Caleb at ###-#### prior to arrival on-site. Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- hallways units 2,4,6 -
MEC19-01878 Final10/24/201910/25/201910/25/2019 10:20:34 AMAPASS
Please call James 30 minutes in advance for access at ###-#### and call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
MEC19-04538 Pressure Test10/24/201910/25/201910/25/2019 10:11:38 AMAPASS
Customer: Ben ###-#### - HVAC: ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- 20lb -
MEC19-04538 Rough-in10/24/201910/25/201910/25/2019 10:11:18 AMAPASS
Customer: Ben ###-#### - HVAC: ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- rough in, 5lb flue -
MEC19-04526 Pressure Test10/24/201910/25/201910/25/2019 9:55:44 AMAPASS
Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 20lb -
MEC19-04781 Final10/22/201910/25/201910/25/2019 9:40:12 AMACANC
Please call Tony, tech on site, at number provided to ensure job is ready. If you have any issues, call Alyssa at ###-####. Thanks! Phone #: ###-#### Inspection requested via web by Alyssa Cromwell
- canc per conv. with tony -
MEC19-03812 Final10/23/201910/25/201910/25/2019 9:22:27 AMAFAIL
access code should be 1968 or 2012 Phone #: ###-#### Inspection requested via web by Angie Maguire
- need blast test report -
- condencer needs locking caps -
MEC19-04746 Final10/23/201910/25/201910/25/2019 9:04:27 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC18-02870 Mec-Aging Inspection10/25/201910/25/201910/25/2019 7:57:05 AM CANC