Inspections for the day of: Friday, December 1, 2017.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-01976 Rough-in12/1/201712/1/201712/1/2017 3:29:51 PMPPASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
207-214 okay
MEC17-03715 Rough-in12/1/201712/1/201712/1/2017 3:00:56 PMPFAIL
Cover Inspection for Dr. Slater TI, please call Albert Ayala ###-#### Phone #: ###-#### Inspection requested via web by Bailey Esposito
1'x4' and 2'x2' return air cans need 2 siesmic support wires
MEC17-04841 Pressure Test12/1/201712/1/201712/1/2017 2:42:47 PMPPASS
Flue test and final Phone #: ###-#### Inspection requested via web by Lea Briggs
5lb flue
MEC17-04841 Final12/1/201712/1/201712/1/2017 2:42:29 PMPPASS
Flue test and final Phone #: ###-#### Inspection requested via web by Lea Briggs
MEC17-04203 Final12/1/201712/1/201712/1/2017 1:52:42 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
armaflex needs uv tape, need to make where lineset enters foundation rodent proof
MEC17-05316 Final11/27/201712/1/201712/1/2017 1:39:54 PMPPASS
PLEASE CALL INSTALLER, DWIGHT BEFORE ARRIVAL TO ENSURE JOB IS COMPLETE ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
MEC17-01965 Final12/1/201712/1/201712/1/2017 12:39:49 PMPPASS
MEC17-05400 Final11/30/201712/1/201712/1/2017 11:14:50 AMAPASS
Rough In / Final inspection at US Bank/ Gardner, contact is
Wayne ###-####. Phone #: ###-#### Inspection requested via web by Kathy Youngkin
MEC17-04433 Conference11/30/201712/1/201712/1/2017 10:41:51 AMAPASS
Travis Phone #: ###-####
when duct can be lowered to inspect the top for sealer okay, if not need to cut a hole to inspect from inside
MEC17-05398 Final11/30/201712/1/201712/1/2017 10:13:15 AMAFAIL
The house is unoccupied. If no one is home, then entry can be done through the unlocked back door. Phone #: ###-#### Inspection requested via web by Steve Bunch
furnace needs to be hard wired to the disconect, armaflex needs uv protection
MEC17-04160 Final11/30/201712/1/201712/1/2017 9:43:26 AMAPASS
Phone #: ###-#### Inspection requested via web by David Petsche
MEC16-05438 Mec-Aging Inspection12/1/201712/1/201712/1/2017 9:25:08 AM PEND
MEC16-04816 Mec-Aging Inspection12/1/201712/1/201712/1/2017 9:23:46 AM CANC
MEC17-02715 Final11/30/201712/1/201712/1/2017 9:23:11 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC17-02907 Final11/29/201712/1/201712/1/2017 8:41:36 AMAPASS
Homeowner will not be home. We just had to move AC to side of disconnect. Phone #: ###-#### Inspection requested via web by Mary LaFayette