Inspections for the day of: Wednesday, December 18, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05615 Final12/17/201912/18/201912/19/2019 5:05:14 PMPPASS
PLEASE CALL TENANT SARA WHEN 30 MINS IN ROUTE. IF AT ALL POSSIBLE PLEASE ANYTIME AFTER 2P AND THEY WILL BE HOME ANYTIME AFTER. Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC19-01716 Final12/18/201912/18/201912/19/2019 9:11:12 AMPPART
Please call Bryan at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum


Items of concern:

F-112 unit undersized for CFM values shown on drawing (if the drawings are revised we will need the new drawings submitted so our documents are updated as well).
F-113 outdoor units needs to be repaired before unit can operate at high speed.
F-103 unit is oversized for the connected CFM load.
F-202 unit is only achieving 78% of designed air flow.
FC-101 and FC-115 Not operating.
Living room A201 missing balance dampers in 6 of the supply branch lines
No access to damper in dining room A154-
- temp C.O. okay -
MEC19-02651 Rough-in12/17/201912/18/201912/18/2019 3:17:58 PMPPASS
Please call Fernando at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- 2nd floor hydronic loop marked in yellow 100 lb test -
MEC19-05431 Final12/18/201912/18/201912/18/2019 2:53:55 PMPPASS
Please call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
MEC19-05681 Rough-in12/18/201912/18/201912/18/2019 2:43:22 PMPPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC19-04671 Final12/18/201912/18/201912/18/2019 2:42:51 PMPPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC19-05115 Final12/18/201912/18/201912/18/2019 2:14:18 PMPPASS
MEC19-05115 Pressure Test12/18/201912/18/201912/18/2019 2:14:00 PMPPASS
- 5lb -
MEC19-02979 Final12/17/201912/18/201912/18/2019 11:23:08 AMAPASS
Phone #: ###-#### Inspection requested via web by Lindsey Stegemann
MEC19-04872 Rough-in12/18/201912/18/201912/18/2019 11:20:22 AMPPASS
Phone #: ###-#### Inspection requested via web by Nathan Britzius
MEC19-04034 Final12/17/201912/18/201912/18/2019 11:09:10 AMAPASS
PROJECT MANAGER - KEVIN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
MEC19-05115 Final12/16/201912/18/201912/18/2019 10:48:22 AMACANC
Phone #: ###-#### Inspection requested via web by Denise Colin
- reschedualed with james -
MEC19-05115 Pressure Test12/16/201912/18/201912/18/2019 10:47:58 AMACANC
Phone #: ###-#### Inspection requested via web by Denise Colin
- reschedualed with james -
MEC19-05678 Rough-in12/17/201912/18/201912/18/2019 10:35:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Lindsey Stegemann
MEC19-05627 Rough-in12/17/201912/18/201912/18/2019 10:09:51 AMAPASS
Phone #: ###-#### Inspection requested via web by Lindsey Stegemann
MEC19-02330 Mec-Aging Inspection12/18/201912/18/201912/18/2019 9:52:51 AM CANC
MEC19-02330 DOC - Permit Expired12/18/201912/18/201912/18/2019 9:52:45 AMPPASS
MEC19-04872 Rough-in12/17/201912/18/201912/18/2019 9:52:01 AMAFAIL
Replaced drain tubing with PVC Phone #: ###-#### Inspection requested via web by Nathan Britzius
- need to use barbed fitting to connect tubing to pvc -
MEC19-05575 DOC - Permit Finaled12/18/201912/18/201912/18/2019 9:27:07 AMPPASS
MEC19-04668 Rough-in12/17/201912/18/201912/17/2019 10:43:19 AMACANC
Mechanical Gas Fireplace Rough-In Inspection. Unit was removed and re-installed. Phone #: ###-#### >> Inspection requested via web by Dan Otero Inspection cancelled from web by: Dan Otero