Inspections for the day of: Friday, February 22, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-00759 Final2/21/20192/22/20192/22/2019 2:56:53 PMPPASS
Homeowner Daniel Barrera ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC18-05315 Final2/22/20192/22/20192/22/2019 2:33:44 PMPPASS
Please ring the door bell, home owner will be home. Thanks. Inspection requested via web by 4 Seasons
MEC19-00790 Final2/21/20192/22/20192/22/2019 2:16:52 PMPNH
customer has been notified. furnace and evaporator replacement. co detectors installed. Phone #: ###-#### Inspection requested via web by shawn miller
customer left note will have to reschedual daughter went into labor
MEC19-00269 Pressure Test2/22/20192/22/20192/22/2019 2:04:44 PMPPASS
Phone #: ###-#### Inspection requested via web by Aaron Alandt
20lb gas,5lb flue x2
MEC19-00269 Rough-in2/22/20192/22/20192/22/2019 2:04:19 PMPPASS
Phone #: ###-#### Inspection requested via web by Aaron Alandt
MEC18-02341 Final2/21/20192/22/20192/22/2019 1:33:24 PMPPASS
Inspection requested via web by Marisa Hone
MEC18-05086 Final2/21/20192/22/20192/22/2019 1:18:56 PMPFAIL
MEC and fire place final
code 7285 Phone #: ###-#### Inspection requested via web by Oleg Chervak
condencer not tied in
MEC19-00697 Pressure Test2/22/20192/22/20192/22/2019 12:43:24 PMPPASS
Rough-in and pressure test. Amy Phone #: ###-####
20lb
MEC18-05256 Final2/22/20192/22/20192/22/2019 10:52:36 AMAPASS
Garage code 3283 Inspection requested via web by JOSE DUARTE
MEC19-00665 Pressure Test2/20/20192/22/20192/22/2019 10:31:25 AMAFAIL
Please call Jace at ###-#### Phone #: ###-#### Inspection requested via web by Amber Orr
outdoor piping needs to be min. 31/2" above ground, test at 3lbs
MEC18-05898 Final2/21/20192/22/20192/22/2019 10:06:52 AMAFAIL
Phone #: ###-#### Inspection requested via web by Eric Sonner
armaflex needs uv protection
MEC18-04744 Final2/21/20192/22/20192/22/2019 9:54:31 AMAPASS
mac fireplace final
7285 Phone #: ###-#### Inspection requested via web by Oleg Chervak
MEC18-05043 Final2/20/20192/22/20192/22/2019 9:38:05 AMAFAIL
Phone #: ###-#### Inspection requested via web by Andrea Creek
need 2nd condensate drain, duct in unconditioned basement needs insulation
MEC19-00505 Rough-in2/21/20192/22/20192/22/2019 9:19:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Arcadio Martinez
MEC19-00154 Final2/21/20192/22/20192/22/2019 9:08:36 AMAPASS
robin # ###-#### Phone #: ###-#### Inspection requested via web by Robin Cox
MEC18-03606 Final2/20/20192/22/20192/22/2019 9:05:44 AMAPASS
Inspection requested via web by Marisa Hone
MEC19-00649 Final2/18/20192/22/20192/22/2019 8:52:43 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC18-02273 Mec-Aging Inspection2/22/20192/22/20192/22/2019 8:28:41 AM CANC
permit will expire next aging if no inspection is schedualed
MEC18-02264 Mec-Aging Inspection2/22/20192/22/20192/22/2019 8:07:19 AM CANC
schedual final, permit will expire next aging
MEC18-02286 Mec-Aging Inspection2/22/20192/22/20192/22/2019 8:05:55 AM CANC
schedual final when rdy