Inspections for the day of: Tuesday, April 10, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-01589 Final4/9/20184/10/20184/10/2018 4:10:20 PMPPASS
please call our lead installer Jonah when 30 mins in route Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC18-01572 Pressure Test4/10/20184/10/20184/10/2018 3:36:38 PMPPASS
please call lead installer Dakoda when 30 mins in route. 3-5p would be preferred today if possible

thank you Phone #: ###-#### Inspection requested via web by Rick Montgomery
20lb gas
MEC18-01574 Final4/9/20184/10/20184/10/2018 3:13:36 PMPPASS
PLEASE CALL OUR LEAD INSTALLER BRAD WHEN 30 MINS IN ROUTE, 2-4P IN AFTERNOON WOULD BE PREFERRED IF POSSIBLE Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC17-05057 Final4/10/20184/10/20184/10/2018 2:45:02 PMPPART
Final Inspection ; Francisco will be your contact Phone #: ###-#### Inspection requested via web by Kim Adams
access door needs to be marked and none locking
MEC17-05404 Final4/10/20184/10/20184/10/2018 2:19:25 PMPFAIL
Bj 5730755 Inspection requested via web by william kerwin
need to run 2nd condensate drain
MEC18-01200 Rough-in4/9/20184/10/20184/10/2018 2:07:32 PMPPASS
Phone #: ###-#### Inspection requested via web by Ashley Stegemann
MEC18-01535 Rough-in4/9/20184/10/20184/10/2018 1:41:57 PMPPART
There are three fireplaces on this property that need a Rough-In inspection. Phone #: ###-#### Inspection requested via web by Ashley Stegemann
gas flex needs sleeve where it enters fireplace cabinet all 3 fireplaces
MEC18-00937 Final4/10/20184/10/20184/10/2018 1:20:38 PMPPASS
Final please today. If you have questions please call Greg ###-#### Phone #: ###-#### Inspection requested via web by Greg Mendiola
MEC16-05598 Mec-Aging Inspection4/10/20184/10/20184/10/2018 11:30:30 AM CANC
MEC16-05598 DOC - Permit Expired4/10/20184/10/20184/10/2018 11:30:17 AMPPASS
MEC18-00998 Final4/10/20184/10/20184/10/2018 11:22:41 AMPCANC
Inspection cancelled from web by: Melissa Kaae
MEC18-01349 Rough-in4/9/20184/10/20184/10/2018 10:57:24 AMAPASS
Inspection requested via web by Baldomero Guzman
double check water heater vent clearances at final in basment coming through wall
MEC18-01566 Rough-in4/9/20184/10/20184/10/2018 10:18:28 AMAPASS
Homeowner wil be there for inspector Phone #: ###-#### Inspection requested via web by Manuel Canto
MEC18-01593 Rough-in4/9/20184/10/20184/10/2018 9:54:22 AMAPASS
Gas fireplace install . gate code #2781

Noah with RCH Construction is POC Phone #: ###-#### Inspection requested via web by Sheldon Lebow
MEC18-00182 Final4/9/20184/10/20184/10/2018 9:18:55 AMAFAIL
Access #5296 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
both furnace and water heater need sediment trap in gas piping
MEC18-00998 Final4/9/20184/10/20184/10/2018 8:44:46 AMANR
Requesting a final inspection for AM.

Contact: Dave Godfrey Phone #: ###-#### Inspection requested via web by Melissa Kaae
returns still need to be tied in
MEC18-00645 Final4/5/20184/10/20184/6/2018 3:20:09 PMACANC
Garage Code is 6997 - Call Jason with any issues @ 412.6696 Phone #: ###-#### >> Inspection requested via web by Dawn Kalsbeek Inspection cancelled from web by: Dawn Kalsbeek