Inspections for the day of: Wednesday, June 17, 2020.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-02156 Final6/15/20206/17/20206/17/2020 4:54:45 PMPPASS
I will text you pictures in AM. Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC20-01009 Final6/17/20206/17/20206/17/2020 3:18:14 PMPPASS
door will be open Phone #: ###-#### Inspection requested via web by Oleg Chervak
MEC20-02316 Final6/15/20206/17/20206/17/2020 2:55:08 PMPPASS
Customer is requesting a PM appt and a courtesy call prior to arrival. Thank you. Susan Karpen Phone #: ###-#### Inspection requested via web by Shari Wetzler
MEC20-01874 Rough-in6/17/20206/17/20206/17/2020 2:23:05 PMPPASS
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero
MEC20-02111 Rough-in6/17/20206/17/20206/17/2020 2:22:44 PMPFAIL
Phone #: ###-#### Inspection requested via web by Kristy Newkirk
- fireplace need gas piping to enter cabinet
then will pass rough-in
MEC20-02459 Rough-in6/17/20206/17/20206/17/2020 2:06:31 PMPFAIL
Greg: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
- need exhaust fans installed
MEC20-01263 Final6/17/20206/17/20206/17/2020 1:44:18 PMPPART
Phone #: ###-#### Inspection requested via web by Gary McFarland
- return grille needs to be installed virtical so it cant be blocked off
- condencer needs locking caps
temp c.o.
MEC20-02467 Final6/17/20206/17/20206/17/2020 1:11:03 PMPPASS
Phone #: ###-#### Inspection requested via web by Aaron Toomey
MEC20-02467 Pressure Test6/17/20206/17/20206/17/2020 1:10:28 PMPPASS
Phone #: ###-#### Inspection requested via web by Aaron Toomey
-20lb
MEC20-00639 Rough-in6/16/20206/17/20206/17/2020 1:08:58 PMPPASS
Please call Ted at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- fire damper and duct seal lower basement
MEC20-02441 Final6/16/20206/17/20206/17/2020 12:33:19 PMPFAIL
Please call Aleks on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- permit will pass when electrical permit is pulled on new disconnect
MEC20-01851 Final6/17/20206/17/20206/17/2020 11:31:40 AMPPASS
I sent pictures this AM Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC19-02330 Mec-Aging Inspection6/17/20206/17/20206/17/2020 11:31:24 AM CANC
permit will expire next aging
MEC20-00157 Final6/16/20206/17/20206/17/2020 11:30:55 AMAPASS
###-#### jeff folmer
call him if garage is not open,
Phone #: ###-#### Inspection requested via web by Oleg Chervak
MEC19-05136 Mec-Aging Inspection6/17/20206/17/20206/17/2020 11:25:03 AM CANC
MEC19-05136 DOC - Permit Expired6/17/20206/17/20206/17/2020 11:24:59 AMPPASS
MEC20-00820 Final6/16/20206/17/20206/17/2020 11:20:50 AMPCANC
Field super: Daryl Thomas
gate code 1957 Phone #: ###-#### Inspection requested via web by Lisa Whitney
- canc per conv. with daryl
MEC20-01060 Final6/16/20206/17/20206/17/2020 11:06:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Abby Ollie
MEC20-00778 Final6/16/20206/17/20206/17/2020 11:05:50 AMAPASS
Phone #: ###-#### Inspection requested via web by Abby Ollie
MEC20-00905 Final6/16/20206/17/20206/17/2020 11:05:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Abby Ollie
MEC20-01354 Rough-in6/17/20206/17/20206/17/2020 11:05:19 AMAPASS
Please contact Wes Hall at the number provided prior to arrival. Phone #: ###-#### Inspection requested via web by RM Mechanical
- 100lb x2 drain downs in sub basement
MEC20-02234 Final6/16/20206/17/20206/17/2020 10:33:17 AMAPASS
Please call Charlie on your way ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
MEC19-03179 Rough-in6/16/20206/17/20206/17/2020 10:01:55 AMAPASS
3rd floor cover Phone #: ###-#### Inspection requested via web by Amanda Farnsworth
- 3rd floor area A duct seal
MEC20-02440 Conference6/17/20206/17/20206/17/2020 9:33:11 AMAFAIL
Call Dave with questions. ###-#### Phone #: ###-#### Inspection requested via web by Dave DeChambeau
- wall clad need to extend up to top of sheet rock
- pizza hood needs tobe raised to 80" per ul listing , brace hood