Inspections for the day of: Wednesday, June 6, 2018.
Number of inspections: 26
Percentage of inspections complete: 96 %
Percentage of inspections not complete: 4 %
Contact Information
InspectorDave Hannah
TitleBLD-COM/RES INSPECTOR
Phone #794-1967
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS18-00151 BLD-Conference5/29/20185/30/2018 A 
New business "Matraex" occupying building, no cert of occupancy.
BLD17-00605 BLD-Aging Inspection6/6/20186/6/20186/11/2018 9:54:37 AM PEND
BLD13-01634 BLD-Aging Inspection6/6/20186/6/20186/11/2018 9:54:04 AM PEND
BLD17-04425 BLD-Foundation6/6/20186/6/20186/7/2018 3:55:53 PMPPASS
Please call Wes if needed. This request is for stem walls at building D-5
Job closes at 4:00 PM.
Thank you. Phone #: ###-#### Inspection requested via web by Justin Palm
BLD17-00954 BLD-Footing6/6/20186/6/20186/6/2018 3:54:48 PMPPASS
John Phone #: ###-####--footings for parking lot
BLD17-02955 BLD-Footing6/6/20186/6/20186/6/2018 3:54:36 PMPPASS
John Phone #: ###-####-footings for parking lot
BLD18-00581 BLD-Final6/6/20186/6/20186/6/2018 3:13:24 PMPPART
Please call upon arrival, Note this inspection is for 3rd floor TCO. I believe all pre inspections are now completed, to be sure I am speaking with all subs to verify. Thank You, Phone #: ###-#### Inspection requested via web by Ron Oswald ok for temp occ on 3rd floor
BLD18-01557 BLD-Final6/5/20186/6/20186/6/2018 2:57:14 PMPPART
Patrick Phone #: ###-#### k for temp occ oko go perm occ after plumging gos perm
BLD15-03904 BLD-Final6/6/20186/6/20186/6/2018 2:09:13 PMPPASS
Final Phone #: ###-#### Inspection requested via web by Joshua Adams
BLD15-03904 DOC - Permit Finaled6/6/20186/6/20186/6/2018 2:09:04 PMPPASS
BLD18-00341 BLD-Final6/6/20186/6/20186/6/2018 2:00:58 PMPPASS
Steve Phone #: ###-####
MIS18-00218 BLD-Conference6/6/20186/6/20186/6/2018 1:36:47 PMPCANC
possible addition being done without a permithed under 120 sq /ft no permit needed
MIS18-00218 DOC - Permit Finaled6/6/20186/6/20186/6/2018 1:36:14 PMPPASS
BLD14-01587 BLD-Final6/5/20186/6/20186/6/2018 1:31:57 PMAPASS
final Phone #: ###-#### Inspection requested via web by Joshua Adams
BLD14-01587 DOC - Permit Finaled6/6/20186/6/20186/6/2018 1:31:47 PMPPASS
BLD17-02469 BLD-Final6/5/20186/6/20186/6/2018 1:31:38 PMANR
Gorge Phone #: ###-####
BLD18-00197 BLD-Footing6/6/20186/6/20186/6/2018 1:23:05 PMPNR
Talyor Phone #: ###-####
BLD14-00685 BLD-Final6/5/20186/6/20186/6/2018 9:54:47 AMAPASS
final Phone #: ###-#### Inspection requested via web by Joshua Adams
BLD14-00685 DOC - Permit Finaled6/6/20186/6/20186/6/2018 9:54:35 AMPPASS
BLD17-02160 BLD-Final6/5/20186/6/20186/6/2018 9:27:16 AMANR
ok to ext permit will start work on garage this mounth
ESC17-00809 Site Final6/5/20186/6/20186/6/2018 9:26:25 AMACANC
BLD17-04587 BLD-Final6/5/20186/6/20186/6/2018 9:18:45 AMAPASS
David Phone #: ###-####
BLD13-02897 BLD-Final6/5/20186/6/20186/6/2018 9:06:48 AMAPASS
Final Phone #: ###-#### Inspection requested via web by Joshua Adams
BLD13-02897 DOC - Permit Finaled6/6/20186/6/20186/6/2018 9:06:39 AMPPASS
BLD18-01226 BLD-Footing6/5/20186/6/20186/6/2018 8:58:34 AMAPASS
Kevin Phone #: ###-####
BLD18-00964 BLD-Framing/Rough-in6/5/20186/6/20186/6/2018 8:38:37 AMAPASS
Zach Phone #: ###-####