Inspections for the day of: Tuesday, May 7, 2019.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTroy Cobbley
TitleFIRE INSPECTOR
Phone #794-9483
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR18-00701 INSP-Sprinkler Rough-in5/7/20195/7/20195/7/2019 2:47:14 PMPPASS
See the city approved plans for areas where piping above the hardlids is ok for cover.


rough to cover // Mike Phone #: ###-####
BLD18-04539 FIRE-Final Inspection5/7/20195/7/20195/7/2019 2:30:14 PMPPASS
Life safety passed

Requested by Shane Treasure Phone #: ###-#### Inspection requested via web by Shane Treasure
FIR19-00309 INSP-Sprinkler Rough-in5/6/20195/7/20195/7/2019 1:10:21 PMAFAIL
Numerous corrections needed. Wil need to be rescheduled when tenting, pipe sizes addressed and install is complete. Gabe Garduno is the contact for this partial RTC. Thank you for your help. Phone #: ###-#### Inspection requested via web by Stan Beus
BLD17-03885 FIRE-Final Inspection5/6/20195/7/20195/7/2019 1:09:13 PMPCANC
Since the project related fire alarm and fire sprinkler permits could not be finaled I did a conference on general life safety requirements. Life safety inspection will need to be rescheduled. This is for fire life safety in building D7 EO wilson Phone #: ###-#### Inspection requested via web by Brandon Reynolds
FIR19-00257 INSP-Alarm Testing5/6/20195/7/20195/7/2019 1:07:55 PMPFAIL
Tested all devices only to find out signals are not going off site for some reason. Testing will need to be redone. PIV tamper is not operating correctly. Contact is Dan. Phone #: ###-#### Inspection requested via web by Morgan Ahten
FIR18-00501 INSP-Final Inspection5/6/20195/7/20195/7/2019 1:06:44 PMPFAIL
No city approved plans or small documents on site. I noted that several branchline restraints are missing, chrome heads are missing in the Croc Display, FDC is not connected, FDC is too high, PIV is too high, need tags and signage, need sprinkler protection under the stairs as discussed, outside alarm bell is not at the FDC, PIV tamper is not working correctly. ......ect.

George Jess is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
FIR19-00296 INSP-Final Inspection5/6/20195/7/20195/7/2019 10:40:54 AMAPASS
Permit finaled

Phone #: ###-#### Inspection requested via web by Ken Webster
NAF18-00142 INSP-Final5/6/20195/7/20195/7/2019 9:55:20 AMPDONE
Life safety passed

Call prior to going Phone #: 2088597458 >> Inspection requested via mobile web by Scott Asin
NAF19-00049 INSP-Final5/6/20195/7/20195/7/2019 9:54:38 AMPDONE
Permit finaled.

Call prior to going Phone #: 5415193272 >> Inspection requested via mobile web by Casey
BLD19-00210 FIRE-Final Inspection5/6/20195/7/20195/7/2019 8:08:03 AMAPASS
Life safety passed, Contractor wil have the suite number up prior to a building inspeciton. Tim Phone #: ###-####
FIR19-00049 INSP-Final Inspection5/6/20195/7/20195/7/2019 8:07:16 AMAPASS
Permit finaled

Todd Ketterling is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus