ESC10-00694
| Aging Inspection | 7/27/2011 | 7/27/2011 | 8/2/2011 4:00:31 PM | | DONE |
|
|
still under construction, site is clean
|
ELE09-02323
| ELE-Aging Inspection | 7/27/2011 | 7/27/2011 | 8/2/2011 3:51:35 PM | | DONE |
|
|
still under construction
|
ELE09-00405
| ELE-Aging Inspection | 7/27/2011 | 7/27/2011 | 8/1/2011 5:14:11 PM | | DONE |
|
|
still under construction
|
MIS11-00179
| ELE-Conference | 7/27/2011 | 7/27/2011 | 7/29/2011 1:30:32 PM | P | DONE |
|
|
Corie Phone #: ###-#### single family dwelling in need of normal electrical maintance, no visible health safety risks.
|
ELE11-01025
| Electrical Rough-In | 7/27/2011 | 7/27/2011 | 7/27/2011 3:47:51 PM | P | PASS |
|
|
jeff Phone #: ###-#### rough-in ok cover second set of apartments--middle units
|
ELE11-01569
| Final | 7/27/2011 | 7/27/2011 | 7/27/2011 3:36:09 PM | P | PASS |
|
|
Call James 20 min before at ###-####. Thank you. Phone #: ###-#### >> Inspection requested via web by Dan Rohl final ok electrical contractor will pull separate permit to repair safety issues with electrical panel.
|
ELE11-01684
| Rough-In Permanent Service | 7/27/2011 | 7/27/2011 | 7/27/2011 3:07:37 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 225-32 the disconnecting means shall be at a readily accessible location nearest point of entrance of the conductors.
|
ELE11-01672
| Electrical Rough-In | 7/26/2011 | 7/27/2011 | 7/27/2011 2:15:06 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Clint Tate ROUGH-IN ok cover walls
|
GCE11-00077
| GCE-Rough-In | 7/26/2011 | 7/27/2011 | 7/27/2011 1:46:30 PM | A | PASS |
|
|
Rough-InHenry @ ###-####PM Inspection rough-in ok lighting retro
|
ELE11-01678
| Electrical Rough-In | 7/27/2011 | 7/27/2011 | 7/27/2011 1:24:55 PM | P | PASS |
|
|
Is ready anytime please give me a call I could meet you there Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman rough-in ok cover sm office,break room
|
ELE11-00005
| Final | 7/27/2011 | 7/27/2011 | 7/27/2011 1:02:07 PM | P | PASS |
|
|
mike - Phone #: ###-#### final ok
|
ELE11-01218
| Final | 7/27/2011 | 7/27/2011 | 7/27/2011 12:49:06 PM | P | PASS |
|
|
lars - please call for access Phone #: ###-#### final ok
|
ELE11-01683
| Temporary Service | 7/27/2011 | 7/27/2011 | 7/27/2011 12:10:42 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Rohl t/s u/g ok
|
ELE11-01642
| Electrical Rough-In | 7/26/2011 | 7/27/2011 | 7/27/2011 11:41:56 AM | A | NH |
|
|
Eric Phone #: ###-####
|
ELE11-01675
| Final | 7/27/2011 | 7/27/2011 | 7/27/2011 10:50:50 AM | A | PASS |
|
|
final ok nice job!! Brandon
|
ELE11-01675
| Electrical Rough-In | 7/26/2011 | 7/27/2011 | 7/27/2011 10:49:44 AM | A | PASS |
|
|
Brandon is the electrician. Ready to final. Phone #: ###-#### >> Inspection requested via web by joel smith rough-in ok all corrections made
|
ELE11-01130
| Final | 7/27/2011 | 7/27/2011 | 7/27/2011 10:31:28 AM | A | PASS |
|
|
Entrance Code 1968E Phone #: ###-#### >> Inspection requested via web by Alan Lusk final ok
|
ELE11-01670
| Permanent Service | 7/26/2011 | 7/27/2011 | 7/27/2011 8:36:43 AM | A | PASS |
|
|
need service inspected, power has been off for over a year. Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin p/s o/h rec ok second ground rod is required with continuous grounging conductor. reattach mast guide cables
|