Inspections for the day of: Monday, July 30, 2012.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
GCE12-00097 GCE-Rough-In7/30/20127/30/20127/30/2012 4:18:47 PMPPASS
Jim @ ###-####
AFternoon inspection for today please. rough-in ok cover hard lid soffets and bathrooms
ELE12-01295 Final7/30/20127/30/20127/30/2012 3:34:45 PMPPASS
late afternoon if possible. Thank you Phone #: ###-#### >> Inspection requested via web by Julie Schroder Final ok
ELE12-01638 Electrical Rough-In7/30/20127/30/20127/30/2012 3:10:30 PMPPASS
STEVE. UNDERGROUND. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy rough-in ok cover underground, back of building #30 Bakery #31 corner area between
ELE12-01889 Conference7/30/20127/30/20127/30/2012 1:20:43 PMPDONE
Lindsay Phone #: ###-#### Discussed with homeowner requirements of single family dwelling remodel
ELE12-01887 Electrical Rough-In7/30/20127/30/20127/30/2012 12:34:01 PMPPASS
Call Todd when you get there to see the project.
###-####
Phone #: ###-#### >> Inspection requested via web by Greg Idsinga rough-in ok cover walls portable unit HIJK behind church
ELE12-01892 Final7/30/20127/30/20127/30/2012 12:10:48 PMPPASS
power for auto gate Final ok
ELE12-01892 Electrical Rough-In7/30/20127/30/20127/30/2012 12:10:02 PMPPASS
please inspect trench from j-box to gate. Pipe is located at the s entrance off of ustick. Please call if you have any questions thanks shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman rough-in ok cover trench
ELE12-01855 Final7/30/20127/30/20127/30/2012 10:27:14 AMPFAIL
Any questions please contact Mike Carter. Phone #: ###-#### >> Inspection requested via web by Vicki Moore NEC 408.8 (B)(1) All 15-20 ampere receptacles in wet locations require listed weather resistance device
ELE12-01855 Electrical Rough-In7/30/20127/30/20127/30/2012 10:08:08 AMAPASS
rough-in ok cover trench ETL listed hot hot
ELE12-00213 ELE-Request for Extension7/27/20127/30/20127/30/2012 9:40:35 AMAPASS
or ###-#### Dan Rothenbuhler Phone #: ###-####
ELE12-01886 Temporary Service7/29/20127/30/20127/30/2012 9:37:31 AMAPASS
accidently put in for a ''final'' inspection and needed only a temp service inspection Phone #: ###-#### >> Inspection requested via web by Candi Bahem t/s o/h n ok
ELE11-02224 Final7/27/20127/30/20127/30/2012 9:28:34 AMAPASS
Call Frank @ ###-#### at least 30 minutes prior to inspection. Phone #: ###-#### >> Inspection requested via web by Kristopher Wilson Final ok
ELE12-00891 Final7/30/20127/30/20127/30/2012 8:59:31 AMAFAIL
code 1049 Phone #: ###-#### >> Inspection requested via web by Neal Rumsey NEC 408.4 Circuit Directory NEC.406.111 Tamper resistanced receptacles NEC.408(B)(1) Listed weather resistanced receptacles outside NEC 314.20 Listed extension ring Micrwave receptacle
ELE12-01432 Final7/29/20127/30/20127/30/2012 8:16:01 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Terry Scott Final ok No sign off card available
ELE12-01550 Final7/29/20127/30/20127/30/2012 8:15:17 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Terry Scott Final ok No sign off card available
ELE12-01551 Final7/29/20127/30/20127/30/2012 8:14:29 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Terry Scott Final ok No sign off card available
ELE12-01552 Final7/29/20127/30/20127/30/2012 8:12:23 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Terry Scott Final ok
ELE12-01886 Final7/29/20127/30/20127/29/2012 11:21:07 PMACANC
>> Inspection requested via web by Candi Bahem Inspection cancelled from web by: Candi Bahem