BLD18-04369
| BLD-Wall Bracing | 1/13/2020 | 1/13/2020 | 1/13/2020 4:28:24 PM | P | PASS |
|
|
90% exterior sheet metal shear inspection Phone #: ###-#### Inspection requested via web by Jared Waggoner
|
BLD18-04243
| BLD-Wall Bracing | 1/13/2020 | 1/13/2020 | 1/13/2020 4:28:11 PM | P | PASS |
|
|
90% partial exterior sheet metal shear inspection Phone #: ###-#### Inspection requested via web by Jared Waggoner
|
BLD19-02930
| BLD-Energy code compliance | 1/13/2020 | 1/13/2020 | 1/13/2020 2:59:27 PM | P | CANC |
|
|
Scott Phone #: ###-####
|
BLD19-02930
| BLD-Framing/Rough-in | 1/13/2020 | 1/13/2020 | 1/13/2020 2:59:16 PM | P | PASS |
|
|
Scott Phone #: ###-####. exterior wood framed walls only ok to insulate.
|
BLD19-04732
| BLD-Final | 1/13/2020 | 1/13/2020 | 1/13/2020 2:38:25 PM | P | PASS |
|
|
Good Morning, Mike, I will be ready for this by 1:00pm. Please let me know if this works for you. Thanks, Elliott ###-#### Inspection requested via web by Elliott Sheffield Jr. All issues have been resolved. BAse in bathroom installed, and Safety film installed on windows with supporting documents.
|
BLD19-03364
| BLD-Framing/Rough-in | 1/13/2020 | 1/13/2020 | 1/13/2020 2:18:10 PM | P | FAIL |
|
|
Sam Phone #: ###-####. Complete lateral bracing on F04 and A02 trusses. Fireblock either side of archway in hall and concelled space at ceiling next to archway. Strap double top plate break at beam seat from beam in garage. Install the 4 simpson screws into each stud for the 2x12 ledger connection. Anchor bolts required for the interior bearing wall in garage. Did the inteior thickend footing get placed with slab? Correction notice posted. Ok to insulate.
|
BLD19-04258
| BLD-Framing/Rough-in | 1/6/2020 | 1/13/2020 | 1/13/2020 1:21:15 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-04255
| BLD-Framing/Rough-in | 1/6/2020 | 1/13/2020 | 1/13/2020 1:21:00 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complete airseal pak. Provide attic access in garage. F4 floor truss installed backwards. Provide (2) 2x under 2ply upstairs (behind tub). Correction notice posted. Ok to insulate.
|
BLD19-04254
| BLD-Framing/Rough-in | 1/10/2020 | 1/13/2020 | 1/13/2020 9:40:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD18-02618
| BLD-Conference | 1/10/2020 | 1/13/2020 | 1/13/2020 9:02:26 AM | A | DONE |
|
|
Robert Phone #: ###-####
|