Inspections for the day of: Monday, January 13, 2020.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-04369 BLD-Wall Bracing1/13/20201/13/20201/13/2020 4:28:24 PMPPASS
90% exterior sheet metal shear inspection Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD18-04243 BLD-Wall Bracing1/13/20201/13/20201/13/2020 4:28:11 PMPPASS
90% partial exterior sheet metal shear inspection Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD19-02930 BLD-Energy code compliance1/13/20201/13/20201/13/2020 2:59:27 PMPCANC
Scott Phone #: ###-####
BLD19-02930 BLD-Framing/Rough-in1/13/20201/13/20201/13/2020 2:59:16 PMPPASS
Scott Phone #: ###-####. exterior wood framed walls only ok to insulate.
BLD19-04732 BLD-Final1/13/20201/13/20201/13/2020 2:38:25 PMPPASS
Good Morning, Mike,
I will be ready for this by 1:00pm. Please let me know if this works for you.
Thanks, Elliott ###-#### Inspection requested via web by Elliott Sheffield Jr. All issues have been resolved. BAse in bathroom installed, and Safety film installed on windows with supporting documents.
BLD19-03364 BLD-Framing/Rough-in1/13/20201/13/20201/13/2020 2:18:10 PMPFAIL
Sam Phone #: ###-####. Complete lateral bracing on F04 and A02 trusses. Fireblock either side of archway in hall and concelled space at ceiling next to archway. Strap double top plate break at beam seat from beam in garage. Install the 4 simpson screws into each stud for the 2x12 ledger connection. Anchor bolts required for the interior bearing wall in garage. Did the inteior thickend footing get placed with slab? Correction notice posted. Ok to insulate.
BLD19-04258 BLD-Framing/Rough-in1/6/20201/13/20201/13/2020 1:21:15 PMPPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-04255 BLD-Framing/Rough-in1/6/20201/13/20201/13/2020 1:21:00 PMPFAIL
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complete airseal pak. Provide attic access in garage. F4 floor truss installed backwards. Provide (2) 2x under 2ply upstairs (behind tub). Correction notice posted. Ok to insulate.
BLD19-04254 BLD-Framing/Rough-in1/10/20201/13/20201/13/2020 9:40:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD18-02618 BLD-Conference1/10/20201/13/20201/13/2020 9:02:26 AMADONE
Robert Phone #: ###-####