Inspections for the day of: Tuesday, January 21, 2020.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-04521 BLD-Wall cover1/21/20201/21/20201/21/2020 4:10:48 PMPCANC
Building 12 - 2nd Floor Insulation and RC channel inspection for cover. Phone #: ###-#### Inspection requested via web by Bob Goodwin
BLD18-04521 BLD-Energy code compliance1/21/20201/21/20201/21/2020 4:10:41 PMPPASS
Building 12 - 2nd Floor Insulation and RC channel inspection for cover. Phone #: ###-#### Inspection requested via web by Bob Goodwin
BLD19-03925 BLD-Framing/Rough-in1/21/20201/21/20201/21/2020 4:06:05 PMPPASS
Curt Phone #: ###-####. Lean to ok.
BLD19-03364 BLD-Energy code compliance1/21/20201/21/20201/21/2020 2:50:21 PMPPASS
Sam Phone #: ###-####
BLD19-03942 BLD-Framing/Rough-in1/21/20201/21/20201/21/2020 2:50:02 PMPFAIL
Jeff Phone #: ###-####. Needs to remove tyvek for wall bracing inspection. Need to verify drag trusses on roof nailing. it is ok to spray ceiling roof deck with the 3 inches of closed cell spray insulation, install fir sprinklers. Will also need to complete foam seal prior to framing inspection..Also noted the the tung and groove material that is going to used on soffits requires Romeo Gervais or Ron Johnsons approval from the fire dpt.
BLD20-00067 BLD-Final1/21/20201/21/20201/21/2020 1:18:32 PMPPASS
call prior ''demo'' - Doug Phone #: ###-####
BLD20-00067 DOC - Permit Finaled1/21/20201/21/20201/21/2020 1:18:20 PMPPASS
BLD19-04372 BLD-Framing/Rough-in1/17/20201/21/20201/21/2020 1:13:40 PMPCANC
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle
BLD19-03316 BLD-Framing/Rough-in1/20/20201/21/20201/21/2020 11:01:24 AMAPASS
can the inspector ring and hour before he goes there as i,am working on to jobs thanks Phone #: ###-#### Inspection requested via web by Glen Farrell
BLD18-04294 BLD-Ceiling Grid Inspection1/20/20201/21/20201/21/2020 9:31:26 AMAPART
Phone #: ###-#### Inspection requested via web by Roger Graves
BLD19-04257 BLD-Framing/Rough-in1/17/20201/21/20201/21/2020 9:01:17 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Needs plumbing rough in inspection.
BLD19-04256 BLD-Framing/Rough-in1/17/20201/21/20201/21/2020 8:51:24 AMAFAIL
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Missed bearing point on F7 floor truss. Provide approved fix for cut top chord on F13 floor truss. Ok to insulate.