Inspections for the day of: Monday, October 2, 2017.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-04506 BLD-Foundation10/2/201710/2/201710/2/2017 3:52:55 PMPPASS
Insulation // Sam Phone #: ###-####
BLD16-04507 BLD-Foundation10/2/201710/2/201710/2/2017 3:52:38 PMPPASS
Insulation // Sam Phone #: ###-####
BLD16-02745 BLD-Wall Bracing10/2/201710/2/201710/2/2017 3:52:29 PMPPASS
Shear // Sam Phone #: ###-####
BLD16-04489 BLD-Foundation10/2/201710/2/201710/2/2017 3:52:18 PMPPASS
Insulation // Sam Phone #: ###-####
BLD16-04490 BLD-Foundation10/2/201710/2/201710/2/2017 3:52:07 PMPPASS
Insulation // Sam Phone #: ###-####
BLD16-04467 BLD-Foundation10/2/201710/2/201710/2/2017 3:51:56 PMPPASS
Rebar // Sam Phone #: ###-####
BLD16-04461 BLD-Foundation10/2/201710/2/201710/2/2017 3:51:46 PMPPASS
Rebar // Sam Phone #: ###-####
BLD16-04462 BLD-Foundation10/2/201710/2/201710/2/2017 3:51:36 PMPPASS
Rebar // Sam Phone #: ###-####
BLD16-04464 BLD-Foundation10/2/201710/2/201710/2/2017 3:51:26 PMPPASS
Rebar // Sam Phone #: ###-####
BLD16-04446 BLD-Foundation10/2/201710/2/201710/2/2017 3:51:14 PMPPASS
Rebar // Sam Phone #: ###-####
BLD16-04313 BLD-Energy code compliance10/2/201710/2/201710/2/2017 2:58:36 PMPNR
David Phone #: ###-####
BLD16-04314 BLD-Energy code compliance10/2/201710/2/201710/2/2017 2:58:23 PMPNR
David Phone #: ###-####
BLD17-01248 BLD-Framing/Rough-in10/2/201710/2/201710/2/2017 1:44:47 PMPFAIL
Electrical Inspection is this afternoon as well.... we need okay to insulate tomorrow Phone #: ###-#### Inspection requested via web by Andrew Clark. Complete airseal after electrical rough in inspection. Nail off 3 ply truss per enginering.Lateral bracing on A2 truss placed at wrong location. Nail off all simpson hangars. Provide headers in doors @ existing exterior wall and install h2.5 on existing truss to wall. Strap top plates from addition to existing top plates. Strap top plates on interior wall at 3ply point load to adjacent wall. Provide continous bearing from 3ply point load to footing. Provide smoke detectors in exisitng bedrooms, hardwired and interconnected. Correction notice posted.
BLD17-02862 BLD-Footing9/29/201710/2/201710/2/2017 10:13:33 AMAPART
Jeremy Phone #: ###-####. Will call in for wall inspection. will be mono placement.
MIS16-00038 MIS-Aging Inspection10/2/201710/2/201710/2/2017 10:06:01 AM PASS
MIS16-00038 DOC - Permit Finaled10/2/201710/2/201710/2/2017 10:05:51 AMPPASS
A permit has been issued and finaled.
BLD17-01656 BLD-Framing/Rough-in9/29/201710/2/201710/2/2017 9:44:44 AMAPASS
Matt-phase 1-Matt said this inspection doesn't have anything to do with the plan mod Phone #: ###-####. Interior steel stud framed walls and wood I-joist ok, phase 1.
BLD16-02745 BLD-Wall Bracing9/29/201710/2/201710/2/2017 8:46:56 AMAFAIL
Sam Phone #: ###-####. Missing blocking, floor to floor straps and noted that not all holdowns are installed.