BLD19-01363
| BLD-Framing/Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 4:37:58 PM | P | NR |
|
|
Kenny Phone #: ###-####
|
BLD19-01363
| BLD-Framing/Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 4:37:58 PM | P | NR |
|
|
Kenny Phone #: ###-####
|
BLD19-01362
| BLD-Framing/Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 4:37:58 PM | P | NR |
|
|
Kenny Phone #: ###-####
|
BLD19-01361
| BLD-Framing/Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 3:36:05 PM | P | NR |
|
|
Kenny Phone #: ###-####
|
BLD19-01360
| BLD-Framing/Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 3:35:52 PM | P | NR |
|
|
Kenny Phone #: ###-####
|
BLD19-01359
| BLD-Framing/Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 3:35:40 PM | P | NR |
|
|
Kenny Phone #: ###-####
|
BLD19-01358
| BLD-Framing/Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 3:35:23 PM | P | NR |
|
|
Kenny Phone #: ###-####
|
BLD19-02151
| BLD-Foundation | 10/2/2019 | 10/2/2019 | 10/2/2019 2:05:28 PM | P | PASS |
|
|
Please call ahead so I can meet Inspector in parking lot and escort back to site inside the compound at West gate. Thank you. Phone #: ###-#### Inspection requested via web by Gary Band. Ok to proceed. Architect/engineer of record to provide letter stating they are accepting the in place work for the conrete anchors.
|
BLD19-01608
| BLD-Final | 10/2/2019 | 10/2/2019 | 10/2/2019 1:47:15 PM | P | PASS |
|
|
Call when close as child could be napping. Phone #: ###-#### Inspection requested via web by Nicholas Rigsby
|
BLD19-01608
| DOC - Permit Finaled | 10/2/2019 | 10/2/2019 | 10/2/2019 1:47:06 PM | P | PASS |
|
|
All issues were resolved.
|
BLD19-03272
| BLD-Other | 10/2/2019 | 10/2/2019 | 10/2/2019 1:20:53 PM | P | PASS |
|
|
Manufactured home block ; tie inspection. Thanks! Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
|
BLD19-03273
| BLD-Other | 10/2/2019 | 10/2/2019 | 10/2/2019 1:17:30 PM | P | PASS |
|
|
REYNA- block and tie Phone #: ###-####
|
BLD19-02678
| BLD-Framing/Rough-in | 10/2/2019 | 10/2/2019 | 10/2/2019 12:53:02 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Todd Landvatter
|
BLD19-03315
| BLD-Footing | 10/1/2019 | 10/2/2019 | 10/2/2019 12:52:33 PM | P | PART |
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru
|
BLD18-00578
| BLD-Final | 10/1/2019 | 10/2/2019 | 10/2/2019 10:56:45 AM | A | NH |
|
|
Garage Code 8188. Electrical has been completed. Call Chris with any concerns. Thank you, Phone #: ###-#### Inspection requested via web by Chris Laraway. All doors are locked. No access to inside of home.
|
BLD12-01277
| BLD-Framing/Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 10:47:03 AM | A | DONE |
|
|
Barba Phone #: ###-####. Needs to insulate.
|
BLD19-01178
| BLD-Framing/Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 10:37:38 AM | A | PASS |
|
|
Wayne- please call for access Phone #: ###-####. All issues were resolved.
|
BLD19-03111
| BLD-Wall Bracing | 10/1/2019 | 10/2/2019 | 10/2/2019 10:26:48 AM | A | PASS |
|
|
Shear // Gottie Phone #: ###-####
|
BLD19-01068
| BLD-Framing/Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 9:48:00 AM | A | PASS |
|
|
Cecel Phone #: ###-####. Pre rock on 2hr. fire wall at soffit.
|
BLD19-02487
| BLD-Footing | 10/1/2019 | 10/2/2019 | 10/2/2019 9:25:05 AM | A | PART |
|
|
Gali Phone #: ###-####
|
BLD19-02878
| BLD-Final | 10/1/2019 | 10/2/2019 | 10/2/2019 9:07:28 AM | A | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Josh Woodbeck
|
BLD19-02878
| DOC - Permit Finaled | 10/2/2019 | 10/2/2019 | 10/2/2019 9:07:14 AM | P | PASS |
|
|
|
ESC19-00355
| Site Final | 10/2/2019 | 10/2/2019 | 10/2/2019 9:06:02 AM | A | DONE |
|
|
|
ESC19-00355
| DOC - Permit Finaled | 10/2/2019 | 10/2/2019 | 10/2/2019 9:05:52 AM | P | PASS |
|
|
|
BLD19-00521
| BLD-Final | 10/1/2019 | 10/2/2019 | 10/2/2019 9:05:28 AM | A | PASS |
|
|
Josh Phone #: ###-####. Ok for perm occ.
|
BLD19-02151
| BLD-Foundation | 10/1/2019 | 10/2/2019 | 10/2/2019 8:52:37 AM | A | PEND |
|
|
Inspection is for anchoring new cooler to slab. Project is at Ada County Sheriffs compound on Barrister, just inside the automated gate at the West end of parking lot. I have a project meeting this morning in adjacent County office, from 8:45 to 9:45. Hopefully we could have Inspection before, or soon after meeting, so work for the day can proceed. I can meet Inspector in parking lot, and escort him into the site. Thank you. Phone #: ###-#### Inspection requested via web by Gary Band. Anchors have been installed with no special inspection. Engineer of record to accept in place work or determine next steps.
|