BLD17-03045
| BLD-Conference | 10/23/2017 | 10/23/2017 | 10/23/2017 5:16:44 PM | P | DONE |
|
|
Noted that barber college was operating with no cert. of occupancy. Fire/life/safety inspection failed, per fire corrections additional horn strobes need to be added and a fire sprinkler head is over spaced. No temp. occupancy has been given by fire inspector. It appears that a fire alarm permit has been issued and treasure valley fire is doing the sprinkler work per the tenant. A correction notice was issued stating that no occupancy is allowed until all fire issues have been resolved and building final has been scheduled and inspected. Did note that the tenant did have a sign at main entry stating that the college was closed until this wednesday.
|
BLD17-00273
| BLD-Framing/Rough-in | 10/23/2017 | 10/23/2017 | 10/23/2017 5:02:19 PM | P | DEFR |
|
|
Cody Phone #: ###-####. No time.
|
BLD17-03466
| BLD-Final | 10/23/2017 | 10/23/2017 | 10/23/2017 4:29:43 PM | P | PASS |
|
|
Daniel Phone #: ###-####. Oki for perm occ.
|
BLD17-02849
| BLD-Footing | 10/22/2017 | 10/23/2017 | 10/23/2017 4:22:06 PM | P | PART |
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo. Due to side set backs, contractor is unaware of impact to existing unit that will require 1hr. eave protection and no openings. Footing ok.
|
BLD16-04311
| BLD-Energy code compliance | 10/22/2017 | 10/23/2017 | 10/23/2017 4:20:38 PM | P | CANC |
|
|
Please do inspection after lunch time, being insulated in AM, Thanks! Phone #: ###-#### Inspection requested via web by david scaggs
|
BLD16-04311
| BLD-Framing/Rough-in | 10/23/2017 | 10/23/2017 | 10/23/2017 4:20:32 PM | P | FAIL |
|
|
Please do inspection after lunch time, being insulated in AM, Thanks! Phone #: ###-#### Inspection requested via web by david scaggs. Frame in dryer vents in units 101 and 103 upstairs and fireblock at ceiling level. complete lateral bracing on C02 trusses in unit 104 and 102. Also provide addtional lateral bracing on top chords of C02 truses in unit 102 were roff sheathing has been left short. Correction notice posted. Ok to insulate.
|
BLD16-04253
| BLD-Conference | 10/20/2017 | 10/23/2017 | 10/23/2017 3:45:58 PM | P | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Darius Saxton
|
BLD17-03259
| BLD-Footing | 10/20/2017 | 10/23/2017 | 10/23/2017 3:19:24 PM | P | PASS |
|
|
Sabastion Phone #: ###-####
|
BLD17-03479
| BLD-Footing | 10/23/2017 | 10/23/2017 | 10/23/2017 2:57:20 PM | P | PASS |
|
|
Gregg Phone #: ###-####
|
BLD17-02066
| BLD-Energy code compliance | 10/20/2017 | 10/23/2017 | 10/23/2017 2:32:37 PM | P | CANC |
|
|
Inspection requested via web by Joel Hirtle
|
BLD17-02066
| BLD-Framing/Rough-in | 10/20/2017 | 10/23/2017 | 10/23/2017 2:32:21 PM | P | FAIL |
|
|
Inspection requested via web by Joel Hirtle. Install the 2x10 scab for BG2 box truss as shown on truss enginering. No wall bracing inspection. Remove tyvek for wall bracing inspection. Correction notice posted. Ok to insulate.
|
BLD16-04501
| BLD-Foundation | 10/23/2017 | 10/23/2017 | 10/23/2017 1:40:09 PM | P | PASS |
|
|
Sam Phone #: ###-####. Rigid insualtion on stemwall under slab on grade.
|
BLD16-04502
| BLD-Foundation | 10/23/2017 | 10/23/2017 | 10/23/2017 1:39:52 PM | P | PASS |
|
|
Sam Phone #: ###-####. Rigid insualtion on stemwall under slab on grade.
|
BLD16-04499
| BLD-Foundation | 10/23/2017 | 10/23/2017 | 10/23/2017 1:39:34 PM | P | PASS |
|
|
Sam Phone #: ###-####. Rigid insualtion on stemwall under slab on grade.
|
BLD16-04498
| BLD-Foundation | 10/23/2017 | 10/23/2017 | 10/23/2017 1:39:18 PM | P | PASS |
|
|
Sam Phone #: ###-####. Rigid insualtion on stemwall under slab on grade.
|
BLD16-04509
| BLD-Footing | 10/23/2017 | 10/23/2017 | 10/23/2017 1:38:39 PM | P | PASS |
|
|
Manual Phone #: ###-####
|
BLD16-04510
| BLD-Footing | 10/23/2017 | 10/23/2017 | 10/23/2017 1:38:22 PM | P | PASS |
|
|
Manual Phone #: ###-####
|
BLD17-03159
| BLD-Footing | 10/23/2017 | 10/23/2017 | 10/23/2017 11:54:28 AM | A | PART |
|
|
As early as possible Phone #: 2086956570 >> Inspection requested via mobile web by Matt Swenson. No approved plans on site. Footing construction appears ok. Called number above and left message. No call back. Contractor may proceed at his own risk, can check setbacks on foundation wall inspection.
|
BLD16-04363
| BLD-Aging Inspection | 10/23/2017 | 10/23/2017 | 10/23/2017 10:47:21 AM | | CANC |
|
|
|
BLD16-02806
| BLD-Foundation | 10/23/2017 | 10/23/2017 | 10/23/2017 10:24:17 AM | P | CANC |
|
|
Stem wall & bar inspect for late PM pour. Phone #: ###-#### >> Inspection requested via web by Ryan Wilhelm Inspection cancelled from web by: Ryan Wilhelm
|
BLD17-03416
| BLD-Footing | 10/20/2017 | 10/23/2017 | 10/23/2017 10:03:02 AM | A | NR |
|
|
jeremy Phone #: ###-####
|
BLD17-00339
| BLD-Other | 10/18/2017 | 10/23/2017 | 10/23/2017 9:36:44 AM | A | PART |
|
|
floor placement // Ross Phone #: ###-####. Welded wire mesh for slab on grade, west half of building. Will install concrete dobi's prior to placement. Will have specil inspection.
|
BLD17-02231
| BLD-Framing/Rough-in | 10/20/2017 | 10/23/2017 | 10/23/2017 8:55:09 AM | A | PASS |
|
|
Darius Phone #: ###-####. Ok to insulate.
|
BLD17-00273
| BLD-Framing/Rough-in | 10/19/2017 | 10/23/2017 | 10/23/2017 12:00:00 AM | P | DONE |
|
|
Cody Phone #: ###-####
|