BLD17-03453
| BLD-Final | 10/6/2017 | 10/6/2017 | 10/6/2017 4:56:28 PM | P | DEFR |
|
|
Solar Installation. Please Call if you would like us to meet you to show the approved plans. Phone #: ###-#### Inspection requested via web by Jesse Simpson. No time.
|
BLD17-01088
| BLD-Final | 10/5/2017 | 10/6/2017 | 10/6/2017 4:44:34 PM | P | PART |
|
|
late as possible // Charles Miller Phone #: ###-####. Ok to occupy O.R. #141 only. Noted all other trades signed off.
|
BLD16-01757
| BLD-Framing/Rough-in | 10/6/2017 | 10/6/2017 | 10/6/2017 4:43:44 PM | P | PART |
|
|
Nathan Phone #: ###-####. Framing for p.c.
|
BLD17-00358
| BLD-Aging Inspection | 10/6/2017 | 10/6/2017 | 10/6/2017 3:21:09 PM | | PASS |
|
|
|
BLD17-01519
| BLD-Final | 10/5/2017 | 10/6/2017 | 10/6/2017 3:05:23 PM | P | NR |
|
|
Jayson Phone #: ###-####. no city approved plans on site.
|
BLD17-02141
| BLD-Wall Bracing | 10/6/2017 | 10/6/2017 | 10/6/2017 2:35:18 PM | P | PASS |
|
|
shear - rod Phone #: ###-####. Exterior shear walls ok.
|
BLD17-01219
| BLD-Final | 10/5/2017 | 10/6/2017 | 10/6/2017 1:55:46 PM | P | PASS |
|
|
Joe Phone #: ###-####. Ok for perm occ.
|
BLD16-03367
| BLD-Aging Inspection | 10/6/2017 | 10/6/2017 | 10/6/2017 1:46:36 PM | | CANC |
|
|
|
BLD16-03367
| DOC - Permit Expired | 10/6/2017 | 10/6/2017 | 10/6/2017 1:46:16 PM | P | PASS |
|
|
|
BLD17-02496
| BLD-Conference | 10/6/2017 | 10/6/2017 | 10/6/2017 1:39:53 PM | P | NR |
|
|
Matt Phone #: ###-####
|
BLD17-02988
| BLD-Footing | 10/6/2017 | 10/6/2017 | 10/6/2017 1:24:43 PM | P | PASS |
|
|
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
|
MIS17-00296
| BLD-Conference | 9/14/2017 | 10/6/2017 | 10/6/2017 11:39:35 AM | A | PASS |
|
|
Need to verify that permit was obtained. Change date per Jim Sly (Call Laura ###-####). Application is under review.
|
BLD17-00729
| BLD-Framing/Rough-in | 10/5/2017 | 10/6/2017 | 10/6/2017 10:56:37 AM | A | PASS |
|
|
Mike Phone #: ###-####. Main entry and bar area.
|
BLD17-00729
| BLD-Energy code compliance | 10/6/2017 | 10/6/2017 | 10/6/2017 10:56:18 AM | A | PASS |
|
|
Mike Phone #: ###-####. West exterior wall.
|
BLD16-04253
| BLD-Ceiling Grid Inspection | 10/5/2017 | 10/6/2017 | 10/6/2017 10:28:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darius Saxton
|
BLD17-02349
| BLD-Framing/Rough-in | 10/5/2017 | 10/6/2017 | 10/6/2017 9:30:38 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Tom Wells. Nail off simpson hangars in garage on LVL's. Provide correct hangars on 2 of the LVL's in the garage. Complete the airseal on plumbing penetrations on the main level. Correction notice issued. Ok to insulate.
|
BLD17-01248
| BLD-Framing/Rough-in | 10/5/2017 | 10/6/2017 | 10/6/2017 8:56:22 AM | A | PASS |
|
|
Andrew Phone #: ###-####. All framing issues have been resolved. Air seal pack completed. Ok to insulate.
|
BLD17-02496
| BLD-Final | 10/5/2017 | 10/6/2017 | 10/6/2017 12:00:00 AM | P | CANC |
|
|
Matt Phone #: ###-#### Per Matt wanted a conference instead
|