BLD18-04294
| BLD-Wall cover | 11/12/2019 | 11/13/2019 | 11/14/2019 6:55:26 AM | P | CANC |
|
|
Requesting a partial wall cover for house keeping walls. Phone #: ###-#### Inspection requested via web by Roger Graves
|
BLD18-04294
| BLD-Wall Bracing | 11/12/2019 | 11/13/2019 | 11/14/2019 6:55:18 AM | P | CANC |
|
|
Requesting a later PM inspection Phone #: ###-#### Inspection requested via web by Roger Graves
|
BLD19-03521
| BLD-Framing/Rough-in | 11/13/2019 | 11/13/2019 | 11/13/2019 4:39:27 PM | P | PART |
|
|
Sid Phone #: ###-####. Portion of 2hr. fire barrier by beam.
|
BLD19-02555
| BLD-Framing/Rough-in | 11/12/2019 | 11/13/2019 | 11/13/2019 4:12:02 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complete lateral bracing on C1, C2 and B2 trusses. Provide strong back on gable end in garage and north side gable. Roll block trusses at shear locations. Fireblock missed areas at 2x4 double next to master bedroom at top plates. install purlins on B trusses top chord were roof sheathing has been omitted. Ok to insulate. Correction notice posted.
|
BLD19-01486
| BLD-Energy code compliance | 11/12/2019 | 11/13/2019 | 11/13/2019 3:44:37 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-01486
| BLD-Framing/Rough-in | 11/12/2019 | 11/13/2019 | 11/13/2019 3:44:23 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-01485
| BLD-Final | 11/12/2019 | 11/13/2019 | 11/13/2019 3:44:09 PM | P | FAIL |
|
|
Door code is 2468 for garage Phone #: ###-#### Inspection requested via web by Joel Hirtle. Provide code compliant stairs from housr to garage.
|
BLD19-01485
| BLD-Blower Door Test Results | 11/13/2019 | 11/13/2019 | 11/13/2019 3:43:08 PM | P | DONE |
|
|
3.59
|
BLD19-01600
| BLD-Ceiling Grid Inspection | 11/13/2019 | 11/13/2019 | 11/13/2019 3:23:28 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Landvatter
|
BLD19-04216
| BLD-Final | 11/12/2019 | 11/13/2019 | 11/13/2019 2:43:09 PM | P | PASS |
|
|
Bobby Phone #: ###-####. Ok for perm. occ.
|
BLD19-04327
| BLD-Framing/Rough-in | 11/13/2019 | 11/13/2019 | 11/13/2019 2:29:03 PM | P | NH |
|
|
call for lock box info // Ethan Phone #: ###-####. No access, no call back for lock box info. Will need to reschedule.
|
BLD19-03519
| BLD-Final | 11/12/2019 | 11/13/2019 | 11/13/2019 2:12:44 PM | P | PASS |
|
|
Rose Phone #: ###-####. Ok for perm occ. Nerw store front from preivous permit also ok.
|
BLD19-04348
| BLD-Framing/Rough-in | 11/13/2019 | 11/13/2019 | 11/13/2019 1:28:24 PM | P | FAIL |
|
|
Allen Phone #: ###-####. Provide hot dipped galvanized nails nails into sill plateat 6 inches on center. Missing fasteners and are overspaced. Missing nails on portal frame, header not long enough. See detail provided on approved plans. Correction notice posted.
|
BLD19-01896
| BLD-Final | 11/13/2019 | 11/13/2019 | 11/13/2019 11:39:26 AM | P | CANC |
|
|
Garage code 4141 Phone #: ###-#### >> Inspection requested via web by Kai Duncan Inspection cancelled from web by: Kai Duncan
|
BLD19-04142
| BLD-Ceiling Grid Inspection | 11/12/2019 | 11/13/2019 | 11/13/2019 11:12:50 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Elliott Sheffield
|
BLD19-04142
| BLD-Framing/Rough-in | 11/12/2019 | 11/13/2019 | 11/13/2019 11:12:33 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Elliott Sheffield
|
BLD19-02672
| BLD-Energy code compliance | 11/12/2019 | 11/13/2019 | 11/13/2019 10:05:29 AM | A | PASS |
|
|
Tyler Phone #: ###-####. Check window in master on final for tempered glazing.
|
BLD19-02672
| BLD-Framing/Rough-in | 11/12/2019 | 11/13/2019 | 11/13/2019 10:05:00 AM | A | PASS |
|
|
Tyler Phone #: ###-####
|
BLD19-04025
| BLD-Final | 11/12/2019 | 11/13/2019 | 11/13/2019 9:39:42 AM | A | PASS |
|
|
Sean Phone #: ###-####
|
BLD19-04025
| DOC - Permit Finaled | 11/13/2019 | 11/13/2019 | 11/13/2019 9:39:34 AM | P | PASS |
|
|
|
BLD19-01556
| BLD-Conference | 11/12/2019 | 11/13/2019 | 11/13/2019 9:38:26 AM | A | DONE |
|
|
Barnie Phone #: ###-####
|
BLD19-01556
| BLD-Energy code compliance | 11/13/2019 | 11/13/2019 | 11/13/2019 9:37:50 AM | A | PASS |
|
|
Barnie Phone #: ###-####
|
BLD19-01556
| BLD-Framing/Rough-in | 11/13/2019 | 11/13/2019 | 11/13/2019 9:37:21 AM | A | PASS |
|
|
Barnie Phone #: ###-####
|
BLD19-03082
| BLD-Other | 11/12/2019 | 11/13/2019 | 11/13/2019 8:42:31 AM | A | PASS |
|
|
Jim- inspection for Sherock Phone #: ###-####
|
BLD19-03081
| BLD-Other | 11/12/2019 | 11/13/2019 | 11/13/2019 8:42:17 AM | A | PASS |
|
|
Jim- inspection for Sherock Phone #: ###-####
|
BLD19-04249
| BLD-Footing | 11/12/2019 | 11/13/2019 | 11/13/2019 8:31:58 AM | A | PART |
|
|
Jeff Phone #: ###-####. Addition and detached garage.
|