Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-02795 BLD-Foundation11/8/201811/9/201811/9/2018 4:13:41 PMPPART
Chad=-slab Phone #: ###-####. Work in progress on interior thickend footings and interior slab on grade. Will have special inspection.
BLD18-01669 BLD-Framing/Rough-in11/9/201811/9/201811/9/2018 3:53:01 PMPFAIL
Phone #: ###-#### Inspection requested via web by Sam Brown. Provide additional studs under the 13/4 X18 LVL. Nail off 2 ply C02 truss upstairs and add additional studs and h2.5. Complete 2hr. assembly at soffits. Install break away clips. Tempered glazing required at window by shower upstairs.
BLD18-01668 BLD-Framing/Rough-in11/9/201811/9/201811/9/2018 3:38:50 PMPFAIL
Phone #: ###-#### Inspection requested via web by Sam Brown. Provide truss engineering. Complete install of break away clips on 2hr. wall. Provide hangars for floor joist in garage to paralam connection. Install addtional studs under 2ply truss upstairs and the H2.5. Complete 2hr assembly at soffits... Correction notice posted.
BLD18-02709 BLD-Final11/8/201811/9/201811/9/2018 3:11:26 PMPPEND
Phone #: ###-#### Inspection requested via web by Brad Cooper
BLD18-00659 BLD-Energy code compliance11/9/201811/9/201811/9/2018 2:44:45 PMPPASS
Mike Phone #: ###-####
BLD18-00659 BLD-Framing/Rough-in11/9/201811/9/201811/9/2018 2:44:38 PMPPART
Mike Phone #: ###-####. Will verify egress window and guard height on final. Home owner is aware of the issues. Also noted that new stairs are not code compliant, bottom riser is 63/8 inch riser height and top riser is only 21/2 inch riser height. Home owner has been made aware of this and that it will need to be made code compliant prior to final.
BLD18-03221 BLD-Final11/9/201811/9/201811/9/2018 2:29:05 PMPDONE
Jim Phone #: ###-####
BLD18-03221 DOC - Permit Finaled11/9/201811/9/201811/9/2018 2:28:56 PMPPASS
BLD18-03886 BLD-Conference11/8/201811/9/201811/9/2018 2:07:57 PMPDONE
Mike Phone #: ###-####
BLD17-03846 BLD-Foundation11/8/201811/9/201811/9/2018 1:26:51 PMPPASS
Dane Phone #: ###-####
BLD18-01912 BLD-Foundation11/8/201811/9/201811/9/2018 1:16:02 PMPPART
Dane Phone #: ###-####
BLD18-02068 BLD-Framing/Rough-in11/9/201811/9/201811/9/2018 1:15:48 PMPCANC
Phone #: ###-#### Inspection requested via web by Jason McKenzie
BLD18-02068 BLD-Wall Bracing11/9/201811/9/201811/9/2018 1:15:43 PMPPASS
Phone #: ###-#### Inspection requested via web by Jason McKenzie
MIS18-00431 BLD-Conference11/8/201811/9/201811/9/2018 11:37:18 AMADEFR
complaint doing major TI work at building. Possible started work on BLD18-00133 that is not issued yet.
BLD18-04019 BLD-Final11/5/201811/9/201811/9/2018 10:45:46 AMADONE
Walter Phone #: ###-####
BLD18-04019 DOC - Permit Finaled11/9/201811/9/201811/9/2018 10:45:37 AMPPASS
BLD18-01191 BLD-Framing/Rough-in11/8/201811/9/201811/9/2018 10:00:38 AMANR
Requesting a ceiling framing inspection in the boys ; girls restroom 112 ; 113. Phone #: ###-#### Inspection requested via web by Markus Schlegel. Needs MEP ri inspections first.
BLD18-02693 BLD-Framing/Rough-in11/8/201811/9/201811/9/2018 9:38:33 AMAPASS
Phil Phone #: ###-####
BLD18-02006 BLD-Energy code compliance11/8/201811/9/201811/9/2018 9:17:50 AMAPASS
Scott Phone #: ###-####
BLD18-02777 BLD-Framing/Rough-in11/8/201811/9/201811/9/2018 9:03:06 AMACANC
Framing / sheer inspection

Phone #: ###-#### Inspection requested via web by Trent Howie
BLD18-02777 BLD-Wall Bracing11/9/201811/9/201811/9/2018 9:02:58 AMAPASS
Framing / sheer inspection

Phone #: ###-#### Inspection requested via web by Trent Howie
BLD18-02127 BLD-Final11/8/201811/9/201811/9/2018 8:55:33 AMANH
Bob Phone #: ###-####. No access, doors locked. Called bob prior to arriving, left message. no call back. will need to reschedule.
BLD18-03283 BLD-Energy code compliance11/8/201811/9/201811/9/2018 8:35:17 AMAFAIL
Gary Phone #: ###-####. Needs to fireblock all fir downs in basement. Correction notice posted.