BLD18-02795
| BLD-Foundation | 11/8/2018 | 11/9/2018 | 11/9/2018 4:13:41 PM | P | PART |
|
|
Chad=-slab Phone #: ###-####. Work in progress on interior thickend footings and interior slab on grade. Will have special inspection.
|
BLD18-01669
| BLD-Framing/Rough-in | 11/9/2018 | 11/9/2018 | 11/9/2018 3:53:01 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown. Provide additional studs under the 13/4 X18 LVL. Nail off 2 ply C02 truss upstairs and add additional studs and h2.5. Complete 2hr. assembly at soffits. Install break away clips. Tempered glazing required at window by shower upstairs.
|
BLD18-01668
| BLD-Framing/Rough-in | 11/9/2018 | 11/9/2018 | 11/9/2018 3:38:50 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown. Provide truss engineering. Complete install of break away clips on 2hr. wall. Provide hangars for floor joist in garage to paralam connection. Install addtional studs under 2ply truss upstairs and the H2.5. Complete 2hr assembly at soffits... Correction notice posted.
|
BLD18-02709
| BLD-Final | 11/8/2018 | 11/9/2018 | 11/9/2018 3:11:26 PM | P | PEND |
|
|
Phone #: ###-#### Inspection requested via web by Brad Cooper
|
BLD18-00659
| BLD-Energy code compliance | 11/9/2018 | 11/9/2018 | 11/9/2018 2:44:45 PM | P | PASS |
|
|
Mike Phone #: ###-####
|
BLD18-00659
| BLD-Framing/Rough-in | 11/9/2018 | 11/9/2018 | 11/9/2018 2:44:38 PM | P | PART |
|
|
Mike Phone #: ###-####. Will verify egress window and guard height on final. Home owner is aware of the issues. Also noted that new stairs are not code compliant, bottom riser is 63/8 inch riser height and top riser is only 21/2 inch riser height. Home owner has been made aware of this and that it will need to be made code compliant prior to final.
|
BLD18-03221
| BLD-Final | 11/9/2018 | 11/9/2018 | 11/9/2018 2:29:05 PM | P | DONE |
|
|
Jim Phone #: ###-####
|
BLD18-03221
| DOC - Permit Finaled | 11/9/2018 | 11/9/2018 | 11/9/2018 2:28:56 PM | P | PASS |
|
|
|
BLD18-03886
| BLD-Conference | 11/8/2018 | 11/9/2018 | 11/9/2018 2:07:57 PM | P | DONE |
|
|
Mike Phone #: ###-####
|
BLD17-03846
| BLD-Foundation | 11/8/2018 | 11/9/2018 | 11/9/2018 1:26:51 PM | P | PASS |
|
|
Dane Phone #: ###-####
|
BLD18-01912
| BLD-Foundation | 11/8/2018 | 11/9/2018 | 11/9/2018 1:16:02 PM | P | PART |
|
|
Dane Phone #: ###-####
|
BLD18-02068
| BLD-Framing/Rough-in | 11/9/2018 | 11/9/2018 | 11/9/2018 1:15:48 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Jason McKenzie
|
BLD18-02068
| BLD-Wall Bracing | 11/9/2018 | 11/9/2018 | 11/9/2018 1:15:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jason McKenzie
|
MIS18-00431
| BLD-Conference | 11/8/2018 | 11/9/2018 | 11/9/2018 11:37:18 AM | A | DEFR |
|
|
complaint doing major TI work at building. Possible started work on BLD18-00133 that is not issued yet.
|
BLD18-04019
| BLD-Final | 11/5/2018 | 11/9/2018 | 11/9/2018 10:45:46 AM | A | DONE |
|
|
Walter Phone #: ###-####
|
BLD18-04019
| DOC - Permit Finaled | 11/9/2018 | 11/9/2018 | 11/9/2018 10:45:37 AM | P | PASS |
|
|
|
BLD18-01191
| BLD-Framing/Rough-in | 11/8/2018 | 11/9/2018 | 11/9/2018 10:00:38 AM | A | NR |
|
|
Requesting a ceiling framing inspection in the boys ; girls restroom 112 ; 113. Phone #: ###-#### Inspection requested via web by Markus Schlegel. Needs MEP ri inspections first.
|
BLD18-02693
| BLD-Framing/Rough-in | 11/8/2018 | 11/9/2018 | 11/9/2018 9:38:33 AM | A | PASS |
|
|
Phil Phone #: ###-####
|
BLD18-02006
| BLD-Energy code compliance | 11/8/2018 | 11/9/2018 | 11/9/2018 9:17:50 AM | A | PASS |
|
|
Scott Phone #: ###-####
|
BLD18-02777
| BLD-Framing/Rough-in | 11/8/2018 | 11/9/2018 | 11/9/2018 9:03:06 AM | A | CANC |
|
|
Framing / sheer inspection
Phone #: ###-#### Inspection requested via web by Trent Howie
|
BLD18-02777
| BLD-Wall Bracing | 11/9/2018 | 11/9/2018 | 11/9/2018 9:02:58 AM | A | PASS |
|
|
Framing / sheer inspection
Phone #: ###-#### Inspection requested via web by Trent Howie
|
BLD18-02127
| BLD-Final | 11/8/2018 | 11/9/2018 | 11/9/2018 8:55:33 AM | A | NH |
|
|
Bob Phone #: ###-####. No access, doors locked. Called bob prior to arriving, left message. no call back. will need to reschedule.
|
BLD18-03283
| BLD-Energy code compliance | 11/8/2018 | 11/9/2018 | 11/9/2018 8:35:17 AM | A | FAIL |
|
|
Gary Phone #: ###-####. Needs to fireblock all fir downs in basement. Correction notice posted.
|