Inspections for the day of: Wednesday, December 11, 2019.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD19-02955 BLD-Final12/11/201912/11/201912/11/2019 4:01:35 PMPFAIL
Randall Phone #: ###-####. Can not verfiy electrical final inspection. provide code compliant stairs, handrails and landing.
BLD19-04171 BLD-Final12/11/201912/11/201912/11/2019 4:00:39 PMPFAIL
Randall Phone #: ###-####Provide code compliant stairs, handrails and landings.
BLD18-03478 BLD-Final12/11/201912/11/201912/11/2019 3:59:51 PMPFAIL
Randall Phone #: ###-####. address issue not resolved.
BLD19-02953 BLD-Final12/11/201912/11/201912/11/2019 3:59:12 PMPFAIL
Randall Phone #: ###-####. Provide landings at bottom of both stairways. Provide code compliant stairs and handrails.
BLD18-02644 BLD-Final12/10/201912/11/201912/11/2019 3:41:54 PMPPASS
Jason Phone #: ###-####
BLD18-02644 DOC - Permit Finaled12/11/201912/11/201912/11/2019 3:41:46 PMPPASS
BLD19-03389 BLD-Framing/Rough-in12/10/201912/11/201912/11/2019 2:31:30 PMPPASS
John Phone #: ###-####. Addition and detached shop only ok to insulate at this time. Detached music room has a shower and that at this time is not allowed. Also plumbing for a seperate sink has been installed that is not shown on approved plans.
BLD19-03933 BLD-Foundation12/10/201912/11/201912/11/2019 2:28:29 PMPPART
2:30 pour // Mark Phone #: ###-####
BLD19-04116 BLD-Foundation12/10/201912/11/201912/11/2019 2:28:13 PMPPART
2:30 pour // Mark Phone #: ###-####
BLD19-02431 BLD-Final12/11/201912/11/201912/11/2019 1:51:00 PMPPASS
DOUG Phone #: ###-####
BLD19-02431 DOC - Permit Finaled12/11/201912/11/201912/11/2019 1:50:53 PMPPASS
BLD19-04372 BLD-Footing12/10/201912/11/201912/11/2019 1:38:16 PMPNR
Dane Phone #: ###-####. No one on site. Concrete form work has not yet been constructed.
BLD19-04257 BLD-Footing12/10/201912/11/201912/11/2019 1:37:58 PMPDONE
Dane Phone #: ###-####. No one on site. Concrete form work has not yet been constructed.
BLD19-04256 BLD-Footing12/10/201912/11/201912/11/2019 1:37:40 PMPNR
Dane Phone #: ###-####. No one on site. Concrete form work has not yet been constructed.
BLD19-02930 BLD-Wall Bracing12/10/201912/11/201912/11/2019 10:40:40 AMANR
Scott Phone #: ###-####. Moved to pm. inspection.
BLD19-03303 BLD-Framing/Rough-in12/10/201912/11/201912/11/2019 10:07:44 AMAFAIL
Anthony Phone #: ###-####. Complete lateral bracing on T15 trusses. Install the missing MSTA 24 straps at RV bay per the engineering. Provide engineering showing the HDU 4 holdownsx at RV bay are sufficient in leiu of the STDH14. Install the missing STDH10 straps at back patio. Install theSTG224 straps at top plate to beam at back patio. Correction notice posted. Ok to insulate.
BLD19-03068 BLD-Framing/Rough-in12/10/201912/11/201912/11/2019 9:03:59 AMAPASS
jUSTIN Phone #: ###-####
BLD19-04249 BLD-Framing/Rough-in12/10/201912/11/201912/11/2019 8:41:48 AMAPASS
Jeff Phone #: ###-####