BLD19-01513
| BLD-Framing/Rough-in | 12/2/2019 | 12/2/2019 | 12/2/2019 4:08:34 PM | P | FAIL |
|
|
Framing/Energy inspection requested. All Subs have passed. Call Brad if there are questions or concerns. Thank you. Phone #: ###-#### Inspection requested via web by Chris Laraway. Complete lateral bracing on BG2, B13, b08, B07 trusses. Missed bearing on BG1 truss. Fireblock garage wall at fir down(plumbing chase). Provide two 2x under D10 2ply truss. Nail bottom chord of D10 2 ply per the engineering. Tempered glazing required in window in upstairs bathroom. Correction notice posted. Ok to insulate.
|
BLD19-02011
| BLD-Energy code compliance | 12/2/2019 | 12/2/2019 | 12/2/2019 3:15:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-02011
| BLD-Framing/Rough-in | 12/2/2019 | 12/2/2019 | 12/2/2019 3:14:50 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-04026
| BLD-Wall Bracing | 12/2/2019 | 12/2/2019 | 12/2/2019 3:14:35 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD18-02407
| BLD-Conference | 12/2/2019 | 12/2/2019 | 12/2/2019 2:59:38 PM | P | PASS |
|
|
aDAM Phone #: ###-####
|
BLD19-02464
| BLD-Footing | 12/1/2019 | 12/2/2019 | 12/2/2019 2:30:03 PM | P | PASS |
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru. Elevator pit, step footings and footings at pool ok.
|
BLD19-03612
| BLD-Final | 11/27/2019 | 12/2/2019 | 12/2/2019 2:08:48 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Michael La Pointe. snow on roof.
|
BLD19-03534
| BLD-Final | 11/27/2019 | 12/2/2019 | 12/2/2019 2:07:32 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Michael La Pointe. Snow on roof.
|
BLD19-03753
| BLD-Framing/Rough-in | 12/2/2019 | 12/2/2019 | 12/2/2019 1:59:02 PM | P | PASS |
|
|
Eric Phone #: ###-####
|
BLD17-01332
| BLD-Conference | 12/2/2019 | 12/2/2019 | 12/2/2019 1:26:13 PM | P | DONE |
|
|
Vlad- please try to call 20 prior Phone #: ###-####. Ok to sheet rock ceilings only.
|
BLD19-04169
| BLD-Footing | 12/2/2019 | 12/2/2019 | 12/2/2019 12:58:54 PM | P | PASS |
|
|
|
BLD19-04179
| BLD-Footing | 12/2/2019 | 12/2/2019 | 12/2/2019 12:58:41 PM | P | PASS |
|
|
|
BLD19-04169
| BLD-Footing | 11/27/2019 | 12/2/2019 | 12/2/2019 12:57:04 PM | A | CANC |
|
|
Dane Phone #: ###-####
|
BLD19-04179
| BLD-Footing | 11/27/2019 | 12/2/2019 | 12/2/2019 12:56:53 PM | A | CANC |
|
|
Dane Phone #: ###-####
|
BLD19-03529
| BLD-Final | 11/27/2019 | 12/2/2019 | 12/2/2019 10:57:19 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Michael La Pointe. Roof covered in snow.
|
BLD19-03738
| BLD-Framing/Rough-in | 11/27/2019 | 12/2/2019 | 12/2/2019 9:35:56 AM | A | PASS |
|
|
Tom Phone #: ###-####. Interior steel stud framed wall ok.
|
BLD19-01731
| BLD-Framing/Rough-in | 12/2/2019 | 12/2/2019 | 12/2/2019 9:11:13 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complete airseal prior to framing inspection. Complete lateral bracing bracing on A5 and A9G trusses. Provide more nails in 2x4 ledger in garage. Nail off B1G truss in garage per the engineering. Correction notice posted.
|
BLD19-02013
| BLD-Energy code compliance | 11/27/2019 | 12/2/2019 | 12/2/2019 8:55:24 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-02013
| BLD-Framing/Rough-in | 11/27/2019 | 12/2/2019 | 12/2/2019 8:55:06 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Framing corrections not completed.
|