Inspections for the day of: Monday, December 2, 2019.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD19-01513 BLD-Framing/Rough-in12/2/201912/2/201912/2/2019 4:08:34 PMPFAIL
Framing/Energy inspection requested. All Subs have passed. Call Brad if there are questions or concerns. Thank you. Phone #: ###-#### Inspection requested via web by Chris Laraway. Complete lateral bracing on BG2, B13, b08, B07 trusses. Missed bearing on BG1 truss. Fireblock garage wall at fir down(plumbing chase). Provide two 2x under D10 2ply truss. Nail bottom chord of D10 2 ply per the engineering. Tempered glazing required in window in upstairs bathroom. Correction notice posted. Ok to insulate.
BLD19-02011 BLD-Energy code compliance12/2/201912/2/201912/2/2019 3:15:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-02011 BLD-Framing/Rough-in12/2/201912/2/201912/2/2019 3:14:50 PMPPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-04026 BLD-Wall Bracing12/2/201912/2/201912/2/2019 3:14:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD18-02407 BLD-Conference12/2/201912/2/201912/2/2019 2:59:38 PMPPASS
aDAM Phone #: ###-####
BLD19-02464 BLD-Footing12/1/201912/2/201912/2/2019 2:30:03 PMPPASS
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru. Elevator pit, step footings and footings at pool ok.
BLD19-03612 BLD-Final11/27/201912/2/201912/2/2019 2:08:48 PMPCANC
Phone #: ###-#### Inspection requested via web by Michael La Pointe. snow on roof.
BLD19-03534 BLD-Final11/27/201912/2/201912/2/2019 2:07:32 PMPCANC
Phone #: ###-#### Inspection requested via web by Michael La Pointe. Snow on roof.
BLD19-03753 BLD-Framing/Rough-in12/2/201912/2/201912/2/2019 1:59:02 PMPPASS
Eric Phone #: ###-####
BLD17-01332 BLD-Conference12/2/201912/2/201912/2/2019 1:26:13 PMPDONE
Vlad- please try to call 20 prior Phone #: ###-####. Ok to sheet rock ceilings only.
BLD19-04169 BLD-Footing12/2/201912/2/201912/2/2019 12:58:54 PMPPASS
BLD19-04179 BLD-Footing12/2/201912/2/201912/2/2019 12:58:41 PMPPASS
BLD19-04169 BLD-Footing11/27/201912/2/201912/2/2019 12:57:04 PMACANC
Dane Phone #: ###-####
BLD19-04179 BLD-Footing11/27/201912/2/201912/2/2019 12:56:53 PMACANC
Dane Phone #: ###-####
BLD19-03529 BLD-Final11/27/201912/2/201912/2/2019 10:57:19 AMACANC
Phone #: ###-#### Inspection requested via web by Michael La Pointe. Roof covered in snow.
BLD19-03738 BLD-Framing/Rough-in11/27/201912/2/201912/2/2019 9:35:56 AMAPASS
Tom Phone #: ###-####. Interior steel stud framed wall ok.
BLD19-01731 BLD-Framing/Rough-in12/2/201912/2/201912/2/2019 9:11:13 AMAFAIL
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complete airseal prior to framing inspection. Complete lateral bracing bracing on A5 and A9G trusses. Provide more nails in 2x4 ledger in garage. Nail off B1G truss in garage per the engineering. Correction notice posted.
BLD19-02013 BLD-Energy code compliance11/27/201912/2/201912/2/2019 8:55:24 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-02013 BLD-Framing/Rough-in11/27/201912/2/201912/2/2019 8:55:06 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Framing corrections not completed.