BLD16-04312
| BLD-Final | 12/20/2017 | 12/21/2017 | 12/21/2017 4:06:37 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Scaggs. Ok for temp occ. Will be ok for perm occ. once zoning and public works signs perm.
|
BLD16-04315
| BLD-Final | 12/20/2017 | 12/21/2017 | 12/21/2017 4:06:11 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Scaggs. Ok for temp occ. Will be ok for perm occ. once zoning and public works signs perm.
|
BLD17-02419
| BLD-Footing | 12/20/2017 | 12/21/2017 | 12/21/2017 3:45:34 PM | P | PASS |
|
|
Concrete scheduled for 2pm Phone #: ###-#### Inspection requested via web by Marty Short
|
BLD17-02417
| BLD-Foundation | 12/20/2017 | 12/21/2017 | 12/21/2017 3:45:22 PM | P | PASS |
|
|
Concrete scheduled for 2pm Phone #: ###-#### Inspection requested via web by Marty Short
|
BLD17-02415
| BLD-Energy code compliance | 12/20/2017 | 12/21/2017 | 12/21/2017 3:44:59 PM | P | PASS |
|
|
Foundation insulation Phone #: ###-#### Inspection requested via web by Marty Short
|
BLD16-04311
| BLD-Final | 12/20/2017 | 12/21/2017 | 12/21/2017 2:55:47 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by David Scaggs
|
BLD17-02793
| BLD-Aging Inspection | 12/21/2017 | 12/21/2017 | 12/21/2017 2:54:51 PM | | CANC |
|
|
|
BLD17-02794
| BLD-Aging Inspection | 12/21/2017 | 12/21/2017 | 12/21/2017 2:54:42 PM | | CANC |
|
|
|
BLD12-01277
| BLD-Aging Inspection | 12/21/2017 | 12/21/2017 | 12/21/2017 2:54:15 PM | | PEND |
|
|
|
BLD16-02905
| BLD-Final | 12/20/2017 | 12/21/2017 | 12/21/2017 2:44:58 PM | P | NR |
|
|
Please call me when you''re on your way and I''ll meet you on site. Phone #: ###-#### Inspection requested via web by Mike Walling. Needs fire/life/safety final.
|
GRD17-00059
| GRD-Final | 12/21/2017 | 12/21/2017 | 12/21/2017 2:44:24 PM | P | NR |
|
|
Call when you get there please // Greg Phone #: ###-####.
|
BLD17-01088
| BLD-Framing/Rough-in | 12/21/2017 | 12/21/2017 | 12/21/2017 2:41:25 PM | P | PASS |
|
|
Charles Phone #: ###-#### Remainder of framing in addition ok.
|
BLD17-02308
| BLD-Foundation | 12/21/2017 | 12/21/2017 | 12/21/2017 2:39:06 PM | P | CANC |
|
|
Chuck-please call Chuck and he''ll tell you where the plans are so you don''t fhave to look all over Phone #: ###-####
|
BLD16-04566
| BLD-Framing/Rough-in | 12/21/2017 | 12/21/2017 | 12/21/2017 2:38:53 PM | P | NR |
|
|
Call to meet // Lee Phone #: ###-####. Needs to rough in electrical and have inspected prior to framing inspection.
|
BLD17-00554
| BLD-Framing/Rough-in | 12/20/2017 | 12/21/2017 | 12/21/2017 2:31:51 PM | P | FAIL |
|
|
Plans and truss engineering above the fireplace. Thanks. Phone #: ###-#### Inspection requested via web by Scott Zierler. Provide strng back on A6 gable end truss. Insufficient bearing on A5 trusses at east interior bearing wall. Remove all roof penetrations from laydown parapet. Nail off all hangers. Bottom chords on 2ply B3 truss not in contact. 2 hr. wall not continous and not to bottom of roof deck. Correction notice posted.
|
BLD17-04036
| BLD-Footing | 12/21/2017 | 12/21/2017 | 12/21/2017 1:34:25 PM | P | PASS |
|
|
Larry-momo-pour Phone #: ###-####. Monoplacement ok. Will place tomorrow. Noted to contractor to ensure ground is not frozen and to cover for 72 hs with 2 layers of concrete blankets.
|
BLD17-02308
| BLD-Footing | 12/21/2017 | 12/21/2017 | 12/21/2017 1:11:06 PM | P | PASS |
|
|
Chuck-please call Chuck and he''ll tell you where the plans are so you don''t fhave to look all over Phone #: ###-####
|
BLD17-03512
| BLD-Foundation | 12/21/2017 | 12/21/2017 | 12/21/2017 1:10:47 PM | P | PASS |
|
|
pour time approx 1pm // Scott Moore ###-####
|
MIS17-00432
| BLD-Conference | 12/20/2017 | 12/21/2017 | 12/21/2017 1:10:32 PM | P | PASS |
|
|
Complaint of working w/out permits (interior).
|
MIS17-00432
| DOC - Permit Finaled | 12/21/2017 | 12/21/2017 | 12/21/2017 1:10:25 PM | P | PASS |
|
|
No one home. No evidence of work taking place.
|
MIS17-00434
| BLD-Conference | 12/21/2017 | 12/21/2017 | 12/21/2017 1:09:34 PM | P | DONE |
|
|
daycare going in w/o any permits. Met tenants on site. They were on site to measure rooms and gather the required info to submit to city.
|
MIS17-00431
| BLD-Conference | 12/21/2017 | 12/21/2017 | 12/21/2017 11:28:11 AM | A | FAIL |
|
|
Permits required for re-roof, interior remodel and window relacement. Correction notice and stop work issued. Also noted electrical, plumbing and mech. work beeing done with no permits. parcel hold and double fee building permit and all trades.
|
BLD17-02426
| BLD-Wall Bracing | 12/21/2017 | 12/21/2017 | 12/21/2017 10:49:04 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by David Scaggs Inspection cancelled from web by: David Scaggs
|
BLD17-04367
| BLD-Framing/Rough-in | 12/20/2017 | 12/21/2017 | 12/21/2017 10:15:17 AM | A | PART |
|
|
Troy Phone #: ###-####. Interior steel stud framed walls ok. Pending plumbing and electrical rough in inspections.
|
BLD17-00359
| BLD-Framing/Rough-in | 12/21/2017 | 12/21/2017 | 12/21/2017 9:51:13 AM | A | PASS |
|
|
Interior steel stud framed walls and soffits, remainder of addiotion ok.
|
BLD17-04366
| BLD-Final | 12/20/2017 | 12/21/2017 | 12/21/2017 8:44:30 AM | A | DONE |
|
|
Michelle Phone #: ###-####
|