Inspections for the day of: Thursday, December 21, 2017.
Number of inspections: 26
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-04312 BLD-Final12/20/201712/21/201712/21/2017 4:06:37 PMPPASS
Phone #: ###-#### Inspection requested via web by David Scaggs. Ok for temp occ. Will be ok for perm occ. once zoning and public works signs perm.
BLD16-04315 BLD-Final12/20/201712/21/201712/21/2017 4:06:11 PMPPASS
Phone #: ###-#### Inspection requested via web by David Scaggs. Ok for temp occ. Will be ok for perm occ. once zoning and public works signs perm.
BLD17-02419 BLD-Footing12/20/201712/21/201712/21/2017 3:45:34 PMPPASS
Concrete scheduled for 2pm Phone #: ###-#### Inspection requested via web by Marty Short
BLD17-02417 BLD-Foundation12/20/201712/21/201712/21/2017 3:45:22 PMPPASS
Concrete scheduled for 2pm Phone #: ###-#### Inspection requested via web by Marty Short
BLD17-02415 BLD-Energy code compliance12/20/201712/21/201712/21/2017 3:44:59 PMPPASS
Foundation insulation Phone #: ###-#### Inspection requested via web by Marty Short
BLD16-04311 BLD-Final12/20/201712/21/201712/21/2017 2:55:47 PMPNR
Phone #: ###-#### Inspection requested via web by David Scaggs
BLD17-02793 BLD-Aging Inspection12/21/201712/21/201712/21/2017 2:54:51 PM CANC
BLD17-02794 BLD-Aging Inspection12/21/201712/21/201712/21/2017 2:54:42 PM CANC
BLD12-01277 BLD-Aging Inspection12/21/201712/21/201712/21/2017 2:54:15 PM PEND
BLD16-02905 BLD-Final12/20/201712/21/201712/21/2017 2:44:58 PMPNR
Please call me when you''re on your way and I''ll meet you on site. Phone #: ###-#### Inspection requested via web by Mike Walling. Needs fire/life/safety final.
GRD17-00059 GRD-Final12/21/201712/21/201712/21/2017 2:44:24 PMPNR
Call when you get there please // Greg Phone #: ###-####.
BLD17-01088 BLD-Framing/Rough-in12/21/201712/21/201712/21/2017 2:41:25 PMPPASS
Charles Phone #: ###-#### Remainder of framing in addition ok.
BLD17-02308 BLD-Foundation12/21/201712/21/201712/21/2017 2:39:06 PMPCANC
Chuck-please call Chuck and he''ll tell you where the plans are so you don''t fhave to look all over Phone #: ###-####
BLD16-04566 BLD-Framing/Rough-in12/21/201712/21/201712/21/2017 2:38:53 PMPNR
Call to meet // Lee Phone #: ###-####. Needs to rough in electrical and have inspected prior to framing inspection.
BLD17-00554 BLD-Framing/Rough-in12/20/201712/21/201712/21/2017 2:31:51 PMPFAIL
Plans and truss engineering above the fireplace. Thanks. Phone #: ###-#### Inspection requested via web by Scott Zierler. Provide strng back on A6 gable end truss. Insufficient bearing on A5 trusses at east interior bearing wall. Remove all roof penetrations from laydown parapet. Nail off all hangers. Bottom chords on 2ply B3 truss not in contact. 2 hr. wall not continous and not to bottom of roof deck. Correction notice posted.
BLD17-04036 BLD-Footing12/21/201712/21/201712/21/2017 1:34:25 PMPPASS
Larry-momo-pour Phone #: ###-####. Monoplacement ok. Will place tomorrow. Noted to contractor to ensure ground is not frozen and to cover for 72 hs with 2 layers of concrete blankets.
BLD17-02308 BLD-Footing12/21/201712/21/201712/21/2017 1:11:06 PMPPASS
Chuck-please call Chuck and he''ll tell you where the plans are so you don''t fhave to look all over Phone #: ###-####
BLD17-03512 BLD-Foundation12/21/201712/21/201712/21/2017 1:10:47 PMPPASS
pour time approx 1pm // Scott Moore ###-####
MIS17-00432 BLD-Conference12/20/201712/21/201712/21/2017 1:10:32 PMPPASS
Complaint of working w/out permits (interior).
MIS17-00432 DOC - Permit Finaled12/21/201712/21/201712/21/2017 1:10:25 PMPPASS
No one home. No evidence of work taking place.
MIS17-00434 BLD-Conference12/21/201712/21/201712/21/2017 1:09:34 PMPDONE
daycare going in w/o any permits. Met tenants on site. They were on site to measure rooms and gather the required info to submit to city.
MIS17-00431 BLD-Conference12/21/201712/21/201712/21/2017 11:28:11 AMAFAIL
Permits required for re-roof, interior remodel and window relacement. Correction notice and stop work issued. Also noted electrical, plumbing and mech. work beeing done with no permits. parcel hold and double fee building permit and all trades.
BLD17-02426 BLD-Wall Bracing12/21/201712/21/201712/21/2017 10:49:04 AMPCANC
Phone #: ###-#### >> Inspection requested via web by David Scaggs Inspection cancelled from web by: David Scaggs
BLD17-04367 BLD-Framing/Rough-in12/20/201712/21/201712/21/2017 10:15:17 AMAPART
Troy Phone #: ###-####. Interior steel stud framed walls ok. Pending plumbing and electrical rough in inspections.
BLD17-00359 BLD-Framing/Rough-in12/21/201712/21/201712/21/2017 9:51:13 AMAPASS
Interior steel stud framed walls and soffits, remainder of addiotion ok.
BLD17-04366 BLD-Final12/20/201712/21/201712/21/2017 8:44:30 AMADONE
Michelle Phone #: ###-####