Inspections for the day of: Tuesday, December 3, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD19-02939 BLD-Foundation11/27/201912/3/201912/3/2019 3:51:44 PMPPASS
rebar // Armando Phone #: ###-####. Interior slab on grade.
BLD18-04288 BLD-Wall cover12/3/201912/3/201912/3/2019 3:18:16 PMPPASS
insulation inspection Phone #: ###-#### Inspection requested via web by Glen Farrell
BLD18-04288 BLD-Energy code compliance12/3/201912/3/201912/3/2019 3:18:13 PMPPASS
insulation inspection Phone #: ###-#### Inspection requested via web by Glen Farrell
BLD19-02930 BLD-Other12/2/201912/3/201912/3/2019 3:03:06 PMPDONE
slab on grade // Scott Phone #: ###-####
BLD19-03317 BLD-Ceiling Grid Inspection12/3/201912/3/201912/3/2019 2:10:00 PMPPASS
Taylor- ready anytime Phone #: ###-####
BLD19-04169 BLD-Foundation12/2/201912/3/201912/3/2019 1:34:13 PMPNR
Dane Phone #: ###-####
BLD19-04179 BLD-Foundation12/2/201912/3/201912/3/2019 1:33:53 PMPCANC
Dane Phone #: ###-####
BLD19-02308 BLD-Framing/Rough-in12/2/201912/3/201912/3/2019 1:33:39 PMPFAIL
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Nail D4G 2ply truss per the engineering. Provide purlins on top chords of B3 and B4 trusses at overbuild were roof sheathing has been left off. Ok to insulate. Correction notice posted.
BLD19-02008 BLD-Final12/2/201912/3/201912/3/2019 1:32:20 PMPPASS
garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-02008 DOC - Permit Finaled12/3/201912/3/201912/3/2019 1:32:12 PMPPASS
All issues have been resolved.
BLD19-01731 BLD-Energy code compliance12/2/201912/3/201912/3/2019 1:31:53 PMPNR
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-01731 BLD-Framing/Rough-in12/2/201912/3/201912/3/2019 1:31:32 PMPPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-02013 BLD-Energy code compliance12/2/201912/3/201912/3/2019 11:45:16 AMAPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-02013 BLD-Framing/Rough-in12/2/201912/3/201912/3/2019 11:45:03 AMAPASS
Inspection requested via web by Joel Hirtle
BLD19-02943 BLD-Footing12/2/201912/3/201912/3/2019 11:23:04 AMAPART
Joe Phone #: ###-####. Work in progress. Special inspector on site.
BLD19-04032 BLD-Conference12/2/201912/3/201912/3/2019 10:16:41 AMADONE
Kai Phone #: ###-####
BLD19-02960 BLD-Final12/2/201912/3/201912/3/2019 9:58:07 AMAPASS
Phone #: 2085591460 >> Inspection requested via mobile web by Aaron Carroll. Ok for perm occ. a Non combustible hardi type siding has been used on interior at main entry.
BLD18-04520 BLD-Framing/Rough-in12/2/201912/3/201912/3/2019 9:54:17 AMAPASS
Full exterior shear inspection for weather barrier cover. Phone #: ###-#### Inspection requested via web by Kris Linnell. 1st. 2nd. and 3rd. floor exterior shear and exterior floor to floor straps. interior holdowns and anchor bolts as well ok. Still need interior floor to floor straps.
BLD18-04294 BLD-Framing/Rough-in12/2/201912/3/201912/3/2019 8:45:18 AMAPASS
Phone #: ###-#### Inspection requested via web by Roger Graves. walls only. Ok to insulate.
BLD18-04294 BLD-Wall Bracing12/2/201912/3/201912/3/2019 8:44:43 AMAPASS
Phone #: ###-#### Inspection requested via web by Roger Graves