Inspections for the day of: Wednesday, February 5, 2020.
Number of inspections: 20
Percentage of inspections complete: 95 %
Percentage of inspections not complete: 5 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD20-00045 BLD-Foundation2/3/20202/4/2020 P 
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
BLD19-04262 BLD-Other2/4/20202/5/20202/5/2020 3:35:35 PMPCANC
Inspection on a basic re-roof job that has since been completed. Phone #: ###-#### Inspection requested via web by Michael La Pointe. Due to snow on roof, no inspection performed at this time.
BLD19-04137 BLD-Other2/4/20202/5/20202/5/2020 3:35:22 PMPCANC
Inspection on a basic re-roof job that has since been completed. Phone #: ###-#### Inspection requested via web by Michael La Pointe. Due to snow on roof, no inspection performed at this time.
BLD19-04044 BLD-Other2/4/20202/5/20202/5/2020 3:35:07 PMPCANC
Inspection on a basic re-roof job that has since been completed. Phone #: ###-#### Inspection requested via web by Michael La Pointe. Due to snow on roof, no inspection performed at this time.
BLD19-04260 BLD-Other2/4/20202/5/20202/5/2020 3:34:53 PMPCANC
Inspection on a basic re-roof job that has since been completed. Phone #: ###-#### Inspection requested via web by Michael La Pointe. Due to snow on roof, no inspection performed at this time.
BLD19-03915 BLD-Other2/4/20202/5/20202/5/2020 3:34:35 PMPCANC
Inspection on a basic re-roof job that has since been completed. Phone #: ###-#### Inspection requested via web by Michael La Pointe. Due to snow on roof, no inspection performed at this time.
BLD19-03656 BLD-Wall Bracing2/5/20202/5/20202/5/2020 2:11:38 PMPFAIL
Vince Phone #: ###-####. Provide 8d hot dipped galvanized nails into sill plate. Nail off all straps. Missing stdh 14 on interior wall. Missed portal frame on interior/exterior wall. needs to install all CMST16 straping and blocking over openeings as noted on wall bracing plans.
BLD19-04536 BLD-Final2/5/20202/5/20202/5/2020 1:30:26 PMPFAIL
Janna Phone #: ###-####. provide code compliant handrail.(34 to 38 inches above nosing of stairs. handrail needs to return. Last step to landing exceeds the 7.75 max rise and exceeds the max 3/8 inch measurement between risers within a flight of stairs.) Handrail also does not meet graspability requirements.
MIS20-00038 BLD-Conference2/4/20202/5/20202/5/2020 12:31:00 PMAPASS
caller reporting remodel to studs being done without permit Phone #: ###-####
MIS20-00038 DOC - Permit Finaled2/5/20202/5/20202/5/2020 12:30:49 PMPPASS
No construction activity at this time.
BLD19-04648 BLD-Final2/4/20202/5/20202/5/2020 11:59:58 AMADONE
Phone #: ###-#### Inspection requested via web by Danny Pardee
BLD19-04648 DOC - Permit Finaled2/5/20202/5/20202/5/2020 11:59:48 AMPPASS
BLD19-03534 BLD-Other2/4/20202/5/20202/5/2020 11:23:40 AMACANC
Inspection on a basic re-roof job that has since been completed. Phone #: ###-#### Inspection requested via web by Michael La Pointe. Due to snow on roof, no inspection performed at this time.
BLD19-03294 BLD-Final2/4/20202/5/20202/5/2020 11:23:16 AMADONE
Daniel Phone #: ###-####
BLD19-03294 DOC - Permit Finaled2/5/20202/5/20202/5/2020 11:23:05 AMPPASS
All work appeared to be done in accordance with local codes and ordiances.
BLD19-03529 BLD-Other2/4/20202/5/20202/5/2020 11:22:27 AMACANC
Inspection on a basic re-roof job that has since been completed. Phone #: ###-#### Inspection requested via web by Michael La Pointe. Due to snow on roof, no inspection performed at this time.
BLD19-03612 BLD-Other2/4/20202/5/20202/5/2020 11:22:08 AMACANC
Inspection on a basic re-roof job that has since been completed. Phone #: ###-#### Inspection requested via web by Michael La Pointe. Due to snow on roof, no inspection performed at this time.
BLD18-01027 BLD-Conference2/4/20202/5/20202/5/2020 11:21:21 AMADONE
Ken Phone #: ###-####. Walk through on 1st and 2nd. floors.
BLD18-04289 BLD-Framing/Rough-in2/4/20202/5/20202/5/2020 9:14:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Glen Farrell
BLD20-00224 BLD-Framing/Rough-in2/4/20202/5/20202/5/2020 8:19:25 AMADONE
Jay will be the on site contact. Phone #: ###-#### Inspection requested via web by BRS Permitting. No ugrade work required to existing roof.