Inspections for the day of: Wednesday, March 11, 2020.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD20-00115 BLD-Wall Bracing3/11/20203/11/20203/11/2020 3:41:01 PMPPASS
Louis Phone #: ###-####
BLD20-00259 BLD-Wall Bracing3/11/20203/11/20203/11/2020 3:40:46 PMPPASS
Louis Phone #: ###-####
BLD19-03753 BLD-Final3/11/20203/11/20203/11/2020 2:56:16 PMPPASS
Eric Phone #: ###-####
BLD19-03753 DOC - Permit Finaled3/11/20203/11/20203/11/2020 2:56:08 PMPPASS
BLD19-03753 BLD-Blower Door Test Results3/11/20203/11/20203/11/2020 2:56:02 PMPDONE
4.0
BLD20-00649 BLD-Framing/Rough-in3/11/20203/11/20203/11/2020 2:14:31 PMPPASS
Matt Phone #: ###-####. Interior steel stud framed walls only ok.
BLD19-03669 BLD-Framing/Rough-in3/9/20203/11/20203/11/2020 1:26:38 PMPFAIL
Justin Phone #: ###-####. Foam top plate penetrations above electrical service. Nail off TJI web stiffeners per the plan. Pressure block 2x4 top chord handstack at front of garage. Correction notice posted. Ok to insulate.
BLD18-01027 BLD-Conference3/6/20203/11/20203/11/2020 10:55:51 AMANR
Walk through to visualy inspect MOB level 2 areas for patch backs on fireproofing and fire rated penetrations. Will reinspect tomorrow.
BLD19-03506 BLD-Final3/10/20203/11/20203/11/2020 10:26:33 AMACANC
Please call 15 minutes prior so I can be there. Wall seal complete. Framing corrections complete Phone #: ###-#### Inspection requested via web by Erik Hagen
BLD19-03506 BLD-Framing/Rough-in3/11/20203/11/20203/11/2020 10:26:25 AMAPART
Please call 15 minutes prior so I can be there. Wall seal complete. Framing corrections complete Phone #: ###-#### Inspection requested via web by Erik Hagen. All previous correction items have been repaired. Ok to foam spray exterior walls and under roof deck. Noted several areas that need fireblocked. Contractor noted that he will have these areas addresed for energy code inspection.
BLD19-03552 BLD-Final3/10/20203/11/20203/11/2020 9:54:05 AMANR
Gabe Phone #: ###-####. Needs zoning final .
BLD19-02464 BLD-Other3/10/20203/11/20203/11/2020 9:35:04 AMAPASS
2 hour wall for elevator shaft inspection - Ed Phone #: ###-####. Per the architect, the 2hr. assembly on plans is in correct and has provided the correct assembly.
BLD19-02464 BLD-Wall Bracing3/10/20203/11/20203/11/2020 9:33:43 AMAPASS
Ed Phone #: ###-####. All nailing on interior and exterior walls ok. All floor to floor straps ok except at pool area and at east interior stairs.
BLD20-00054 BLD-Energy code compliance3/11/20203/11/20203/11/2020 7:17:52 AMACANC
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle