BLD18-02914
| BLD-Final | 3/5/2019 | 3/6/2019 | | A | |
|
|
please call for garage code Phone #: ###-#### >> Inspection requested via web by anthony boyd
|
BLD18-04563
| BLD-Foundation | 3/11/2019 | 3/12/2019 | 3/12/2019 3:57:34 PM | P | PASS |
|
|
Dane Phone #: ###-####
|
BLD17-04387
| BLD-Foundation | 3/11/2019 | 3/12/2019 | 3/12/2019 3:57:34 PM | P | PASS |
|
|
Dane Phone #: ###-####
|
BLD19-00422
| BLD-Framing/Rough-in | 3/12/2019 | 3/12/2019 | 3/12/2019 3:18:02 PM | P | PART |
|
|
Elaine Phone #: ###-####. Complete airseal and all fireblocking.
|
BLD18-03836
| BLD-Framing/Rough-in | 3/11/2019 | 3/12/2019 | 3/12/2019 2:26:51 PM | P | PART |
|
|
patio // Eric Phone #: ###-####. Exterior wood framed walls for patio enclosure. Needs to add the missed A34's and needs electrical rough in inspection.
|
BLD19-00681
| BLD-Final | 3/8/2019 | 3/12/2019 | 3/12/2019 2:00:55 PM | P | PASS |
|
|
Emily Phone #: ###-####. Ok for perm occ.
|
BLD18-03312
| BLD-Footing | 3/8/2019 | 3/12/2019 | 3/12/2019 1:32:54 PM | P | PASS |
|
|
Call prior to going Phone #: 8015141543 >> Inspection requested via mobile web by Mike Allred
|
BLD18-03200
| BLD-Foundation | 3/12/2019 | 3/12/2019 | 3/12/2019 1:32:37 PM | P | PASS |
|
|
inpection for slab on grade-Jean Phone #: ###-####
|
BLD18-04357
| BLD-Final | 3/11/2019 | 3/12/2019 | 3/12/2019 10:16:29 AM | A | PASS |
|
|
|
BLD18-04357
| DOC - Permit Finaled | 3/12/2019 | 3/12/2019 | 3/12/2019 10:16:20 AM | P | PASS |
|
|
|
BLD18-04357
| BLD-Framing/Rough-in | 3/11/2019 | 3/12/2019 | 3/12/2019 10:16:07 AM | A | PASS |
|
|
|
BLD18-04399
| BLD-Framing/Rough-in | 3/11/2019 | 3/12/2019 | 3/12/2019 9:51:33 AM | A | FAIL |
|
|
Gari Phone #: ###-####. Install the missed holddown on the south side of the dinning room portal frame. Install missed lateral bracing on truses T2, T3, T4 and t17. Nail off the T21 2 ply per the engineering. Provide additional 2x6 stud under the T18 truss at bearing. Ok to insulate. Correction notice posted.
|
BLD18-04399
| BLD-Wall Bracing | 3/11/2019 | 3/12/2019 | 3/12/2019 9:49:15 AM | A | PASS |
|
|
Gari Phone #: ###-####. Ok to install tyvek.
|
BLD18-03298
| BLD-Foundation | 3/11/2019 | 3/12/2019 | 3/12/2019 9:01:32 AM | A | PASS |
|
|
As early as possible Phone #: 2088708888 >> Inspection requested via mobile web by Wes
|