Inspections for the day of: Friday, March 27, 2020.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD20-00115 BLD-Framing/Rough-in3/27/20203/27/20203/27/2020 4:40:22 PMPCANC
allan Phone #: ###-####
BLD19-03316 BLD-Final3/27/20203/27/20203/27/2020 4:40:11 PMPCANC
BLD19-01264 BLD-Framing/Rough-in3/27/20203/27/20203/27/2020 4:39:56 PMPPASS
BLD19-01264 BLD-Framing/Rough-in3/27/20203/27/20203/27/2020 4:39:42 PMPCANC
BLD20-00076 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 3:56:00 PMPFAIL
requesting framing and air seal inspection. access is lock box code 7777, located to left of garage doors attached to water spigot. Permit located in garage on south wall. Thank you Phone #: ###-#### Inspection requested via web by Dean Rhodes. Fireblock mech. chase at ceiling on main level. Strap double top plate break at new to existing framing by main door. Fire block all fir downs and fir outs in basement. Correction notice posted. Ok to insulate.
BLD20-00115 BLD-Energy code compliance3/27/20203/27/20203/27/2020 2:56:49 PMPPASS
allan Phone #: ###-####
BLD19-04307 BLD-Final3/26/20203/27/20203/27/2020 2:46:49 PMPFAIL
any problems w/ access please call Dean Rhodes ###-####. Final electrical inspection today and final plumbing inspection tomorrow morning, if either of these fail please cancel inspection and please notify me, thank you Phone #: ###-#### Inspection requested via web by Dean Rhodes. Provide code compliant guards and handrail on exterior stairs. Engineering required on cable guards. Provide CO detectors upstairs and downstairs.
BLD17-02922 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 2:12:01 PMPPASS
Phone #: ###-#### Inspection requested via web by John Rott
BLD20-00152 BLD-Energy code compliance3/26/20203/27/20203/27/2020 1:52:24 PMPNR
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD20-00152 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 1:52:05 PMPNR
Inspection requested via web by Joel Hirtle
BLD20-00273 BLD-Conference3/27/20203/27/20203/27/2020 1:24:24 PMPDONE
didn''t leave name Phone #: ###-####
BLD20-00222 BLD-Footing3/26/20203/27/20203/27/2020 11:50:21 AMADEFR
pat Phone #: ###-####. Concrete for footings already placed. Contractor accepts all responsibility for foundation system
BLD20-00527 BLD-Footing3/27/20203/27/20203/27/2020 11:27:38 AMADEFR
moved to pm inspection.
BLD20-00775 BLD-Footing3/26/20203/27/20203/27/2020 11:27:18 AMADEFR
greg Phone #: ###-####. Moved to pm inspection.
BLD19-01264 BLD-Framing/Rough-in3/23/20203/27/20203/27/2020 11:26:56 AMADEFR
Phone #: ###-#### Inspection requested via web by Clint Wall. Moved to pm inspection.
GRD19-00093 GRD-Other3/24/20203/27/20203/27/2020 11:22:02 AMAPART
rebar // angela Phone #: ###-####. Work in progress on rebar install. Ok to place concrete pending special inspection approval.
BLD20-00527 BLD-Foundation3/25/20203/27/20203/27/2020 11:21:13 AMACANC
Brant Phone #: ###-####. Work in progress on retaing wall rebar. wrong entry.
BLD20-00821 BLD-Foundation3/26/20203/27/20203/27/2020 9:48:44 AMAPART
As early as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell. Noted that stemwall placement does not met the projection in some areas. Will need to dowel footing and provide addtional footing .
BLD19-04921 BLD-Foundation3/26/20203/27/20203/27/2020 9:33:13 AMAPASS
steel. any time 10:00 on. Phone #: ###-#### Inspection requested via web by Todd Landvatter. Interior slab on grade ok.
BLD19-01513 BLD-Final3/26/20203/27/20203/27/2020 9:09:50 AMAPASS
Call when in route please. Thank you. Entry Code 4646 Phone #: ###-#### Inspection requested via web by Chris Laraway
BLD19-01513 DOC - Permit Finaled3/27/20203/27/20203/27/2020 9:09:41 AMPPASS
All issues have been resolved. Ok for perm occ.
BLD19-03316 BLD-Final3/26/20203/27/20203/27/2020 8:57:27 AMACANC
Please call before arrival. Project is behind locked gates and no superintendent is on site. I am 15 minutes from the job site. Phone #: ###-#### Inspection requested via web by Ian Franklin. Moved to pm inspection.
BLD20-00151 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 8:54:05 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Needs mech. and electrical rough in in inspections.
BLD20-00261 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 8:53:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-04921 BLD-Foundation3/26/20203/27/20203/26/2020 11:37:43 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Todd Landvatter Inspection cancelled from web by: Todd Landvatter