Inspections for the day of: Monday, March 4, 2019.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-02795 BLD-Foundation3/4/20193/4/20193/4/2019 4:59:22 PMPDEFR
masonry rebar // Chad Phone #: ###-####
BLD18-04490 FIRE-Final Inspection3/1/20193/4/20193/4/2019 4:14:34 PMAFAIL
Jordan-call to meet 30 minutes prior to meet for access Phone #: ###-####. provide annual inspection on fire extinguisher, provide the sticker at the main entry. A seperate building permit isrequired for the vanilla shell space that has been created. Also a demo permit may be required for the sprinkler sysytem that is no longer in use.
BLD19-00044 BLD-Final3/1/20193/4/20193/4/2019 3:22:12 PMPDONE
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher
BLD19-00044 DOC - Permit Finaled3/4/20193/4/20193/4/2019 3:22:03 PMPPASS
BLD18-04206 BLD-Ceiling Grid Inspection3/1/20193/4/20193/4/2019 3:21:50 PMPPASS
Will Phone #: ###-####
BLD18-03684 BLD-Framing/Rough-in3/4/20193/4/20193/4/2019 3:07:00 PMPPASS
Bryan Phone #: ###-####. Interior steel stud framed walls and soffits only for phase 1.
BLD19-00461 BLD-Framing/Rough-in3/4/20193/4/20193/4/2019 2:31:09 PMPFAIL
Call ahead // charles Phone #: ###-####. Remove screws from top plate to grid and instakickers to the structure. Also needs to provide the approvd plans.
BLD18-04578 BLD-Framing/Rough-in3/4/20193/4/20193/4/2019 2:10:10 PMPCANC
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD19-00519 BLD-Wall cover3/4/20193/4/20193/4/2019 2:09:48 PMPFAIL
Phone #: ###-#### Inspection requested via web by Timothy Gammill. Strap double top plate at interior bearing wall in laundry room at oval duct penetration. foam all penetrations in top and bottom plates. Fire block at top of fir down at new wall between mud room and bath. Correction notice posted.
BLD18-03779 BLD-Wall Bracing3/1/20193/4/20193/4/2019 11:57:35 AMAPASS
Curtis Phone #: ###-####
BLD18-02591 BLD-Wall Bracing3/3/20193/4/20193/4/2019 11:57:34 AMAPASS
Please call ahead of time as approved plans are in the trailer. Phone #: ###-#### Inspection requested via web by Clayton Conner
BLD18-04578 BLD-Energy code compliance3/4/20193/4/20193/4/2019 9:07:48 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Wrong lot called in? framing scheduled for pm inspection.
BLD17-04462 BLD-Other3/1/20193/4/20193/4/2019 8:46:31 AMAPASS
Inspection of rated soffits. Thanks. Phone #: ###-#### Inspection requested via web by Scott Zierler
BLD17-04461 BLD-Other3/1/20193/4/20193/4/2019 8:46:13 AMAPASS
Inspection of rated soffits. Phone #: ###-#### Inspection requested via web by Scott Zierler