Inspections for the day of: Friday, April 17, 2020.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD20-00416 BLD-Final4/16/20204/17/20204/17/2020 3:46:48 PMPNR
Phone #: ###-#### Inspection requested via web by Robert Carlton. A life/safety final is required prior to building final.
BLD20-01173 BLD-Final4/17/20204/17/20204/17/2020 3:46:07 PMPPASS
Thank you! Phone #: ###-#### Inspection requested via web by Dale Hope
BLD20-01173 DOC - Permit Finaled4/17/20204/17/20204/17/2020 3:46:00 PMPPASS
BLD20-00426 BLD-Foundation4/16/20204/17/20204/17/2020 1:47:04 PMPPART
screened // Dane Phone #: ###-####
BLD20-00427 BLD-Foundation4/16/20204/17/20204/17/2020 1:46:55 PMPPART
screened // Dane Phone #: ###-####
BLD20-00424 BLD-Foundation4/16/20204/17/20204/17/2020 1:46:45 PMPPART
screened // Dane Phone #: ###-####
BLD20-00425 BLD-Foundation4/16/20204/17/20204/17/2020 1:46:36 PMPPART
screened // Dane Phone #: ###-####
BLD20-00422 BLD-Foundation4/16/20204/17/20204/17/2020 1:46:26 PMPPART
screened // Dane Phone #: ###-####
BLD20-00423 BLD-Foundation4/16/20204/17/20204/17/2020 1:46:14 PMPPART
screened // Dane Phone #: ###-####
BLD20-00371 BLD-Foundation4/16/20204/17/20204/17/2020 1:45:47 PMPPART
screened // Dane Phone #: ###-####
BLD20-00444 BLD-Framing/Rough-in4/17/20204/17/20204/17/2020 12:14:11 PMPFAIL
Phone #: ###-#### Inspection requested via web by Allen Jones. Complete lateral bracing on A07 trusses. Provide additional purlin on top chords of A07 trusses in garage were OSB sheathing for roof has been omitted. Provide additional stud under top plate break on racked wall and also provide plate connection at corner. (single top plate.) Appears that A06 and A06A trusses are placed in incorrect lay out. Provide fix. Provide additional roll blocking at top of raised heal trusses at front patio area. Ok to insulate. Correction notice posted.
BLD20-00359 BLD-Footing4/16/20204/17/20204/17/2020 11:44:21 AMAFAIL
Michael Phone #: ###-####. Noted that ICF product for footing is going to be used. This product was not sent to plan review for initial review. Gave home owner Christinas number to get an email invite so that the ICC ESR report and manufactures tech data can be uploaded for reveiw.
BLD19-02851 BLD-Concrete4/16/20204/17/20204/17/2020 10:10:18 AMAPART
screened // rebar - pouring at 1:45 // Taylor Phone #: ###-####. perimeter column pad footings. Work in progress on completed reinforcement. Ok to place conc. pending special inspection.
BLD19-00733 BLD-Final4/16/20204/17/20204/17/2020 9:25:12 AMACANC
BLD20-00295 BLD-Foundation4/15/20204/17/20204/17/2020 9:23:54 AMAPART
Rod Phone #: ###-####. Perimeter stemwall. Noted column ties at brace frame not per plan. Special inspector to make note of repair prior to concrete placement.
BLD19-03925 BLD-Final4/16/20204/17/20204/17/2020 8:33:17 AMAPASS
shop // kurt Phone #: ###-####
BLD19-03925 DOC - Permit Finaled4/17/20204/17/20204/17/2020 8:33:08 AMPPASS
Noted that the home owner will need to apply for a seperate building permit to construct the restroom when ready.
BLD20-00416 BLD-Final4/16/20204/17/20204/16/2020 2:14:11 PMACANC
Phone #: ###-#### >> Inspection requested via web by Robert Carlton Inspection cancelled from web by: Robert Carlton