BLD16-03176
| BLD-Conference | 4/26/2017 | 4/27/2017 | 4/27/2017 4:44:21 PM | A | PEND |
|
|
Check status/scheduling of project. K2 Construction has done some door infill and added some doors. Per K2 this was there scope of work only. I called and left a message with Gabriel Wilson, owner of ABU games but have not received a call back as of 4:40pm today. Will stop by tomorrow and issue a correction notice if needed.
|
BLD16-02899
| BLD-Other | 4/27/2017 | 4/27/2017 | 4/27/2017 4:32:15 PM | P | PASS |
|
|
smoke wall insp// Herb Phone #: ###-####. Smoke barrier, east wing abve ceiling grid ok.
|
BLD17-00657
| BLD-Wall Bracing | 4/27/2017 | 4/27/2017 | 4/27/2017 2:57:22 PM | P | PASS |
|
|
Zayn Phone #: ###-####
|
BLD17-00973
| BLD-Final | 4/27/2017 | 4/27/2017 | 4/27/2017 2:15:08 PM | P | PASS |
|
|
Phone #: ###-####. Ok for perm occ.
|
BLD17-00919
| BLD-Conference | 4/27/2017 | 4/27/2017 | 4/27/2017 1:52:12 PM | P | PASS |
|
|
Jana Phone #: ###-####
|
BLD17-00919
| DOC - Permit Finaled | 4/27/2017 | 4/27/2017 | 4/27/2017 1:52:02 PM | P | PASS |
|
|
|
BLD17-00561
| BLD-Final | 4/27/2017 | 4/27/2017 | 4/27/2017 1:32:19 PM | P | NR |
|
|
Dean Phone #: ###-####. Needs to have electrical final first.
|
BLD17-00973
| BLD-Footing | 4/26/2017 | 4/27/2017 | 4/27/2017 9:21:53 AM | A | FAIL |
|
|
Marcus Phone #: ###-####. A correction notice was issued. Door was open, no one on site. Could not locate city plans and documents. Appears that fire has not yet signed off. Called Marcus twice at provided number. No awnser. Not able to leave message, voice mail not set up.
|
BLD17-00463
| BLD-Framing/Rough-in | 4/26/2017 | 4/27/2017 | 4/27/2017 8:55:19 AM | A | FAIL |
|
|
As early as possible Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Disregard previous framing inspection, done on wrong house. Complete lateral bracing on A02 trusses. Nail off all simpson hangars. Fireblock behind tub in masterbedroom. Repair bottom plate in master bedroom. Strap double top plates at peak on racked walls. Noted several studs in racked walls cut to short.-replace. Ok to insulate. Correction notice posted.
|
BLD17-00762
| BLD-Footing | 4/26/2017 | 4/27/2017 | 4/27/2017 8:55:19 AM | A | PART |
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo lira
|