BLD20-01178
| BLD-Final | 4/30/2020 | 4/30/2020 | 4/30/2020 2:27:50 PM | P | PASS |
|
|
call first Phone #: ###-#### Inspection requested via web by Todd Landvatter
|
BLD20-01178
| DOC - Permit Finaled | 4/30/2020 | 4/30/2020 | 4/30/2020 2:27:42 PM | P | PASS |
|
|
|
BLD20-01145
| BLD-Framing/Rough-in | 4/30/2020 | 4/30/2020 | 4/30/2020 2:27:30 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Landvatter
|
BLD19-04696
| BLD-Final | 4/30/2020 | 4/30/2020 | 4/30/2020 2:05:04 PM | P | FAIL |
|
|
*screened* lot vacant, call for code - Gary Phone #: ###-####. BAckfill around foundation for frost depth and grade for drainage. Set pins on 20 min. door to be self closeing.
|
BLD20-00749
| BLD-Framing/Rough-in | 4/30/2020 | 4/30/2020 | 4/30/2020 12:38:37 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Allen Jones. Nail off simpson hangars in garage. strapglue lam to 6x6. strap header to studs at mudroom. Strap double top plate cut at plumbing penetration in kithchen. Complete lateral bracing on A01, C01 and C02 trusses. Correction notice posted. Ok to insulate.
|
BLD20-00363
| BLD-Final | 4/30/2020 | 4/30/2020 | 4/30/2020 11:57:11 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Todd Landvatter Inspection cancelled from web by: Todd Landvatter
|
BLD19-02851
| BLD-Footing | 4/29/2020 | 4/30/2020 | 4/30/2020 11:24:36 AM | A | PART |
|
|
Screened- Rebar inspection-Taylor Phone #: ###-####. West half, interior slab on grade.
|
BLD20-00501
| BLD-Footing | 4/29/2020 | 4/30/2020 | 4/30/2020 10:50:57 AM | A | PASS |
|
|
Mike Phone #: ###-####. Footings for patiot cover.
|
BLD19-04112
| BLD-Final | 4/29/2020 | 4/30/2020 | 4/30/2020 10:34:01 AM | A | PASS |
|
|
Screened- Dave Phone #: ###-####. Ok for perm occ. Noted that added sinks and water hearter installed with no permits has been removed.
|
BLD19-02939
| BLD-Final | 4/29/2020 | 4/30/2020 | 4/30/2020 10:15:37 AM | A | PART |
|
|
Call for access Phone #: 2085591460 >> Inspection requested via mobile web by Aaron Carroll. Ok for temp. occ. Noted vertical grab bars not within the 39 to 41 inch.
|
BLD18-04519
| BLD-Framing/Rough-in | 4/29/2020 | 4/30/2020 | 4/30/2020 8:43:11 AM | A | PASS |
|
|
Ceiling drops for cover, Building 10 (12 units). Phone #: ###-#### Inspection requested via web by Bob Goodwin
|
BLD20-00351
| BLD-Energy code compliance | 4/29/2020 | 4/30/2020 | 4/30/2020 8:25:47 AM | A | PASS |
|
|
screened // Gene Phone #: ###-####
|