Inspections for the day of: Monday, May 21, 2018.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
GRD17-00089 GRD-Final5/15/20185/21/20185/21/2018 4:25:04 PMPNR
Kyle Phone #: ###-####. Needs ESC and public works finals.
BLD18-00955 BLD-Other5/21/20185/21/20185/21/2018 4:04:08 PMPPASS
Allen- structural steel bolt connection Phone #: ###-####
BLD18-00374 BLD-Framing/Rough-in5/21/20185/21/20185/21/2018 3:57:25 PMPFAIL
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Complete lateral bracing on A6 truss. LAteral bracing on B2, B3 and B4 trusses connected to wrong member, attach to webs, not top chord. Fireblock at ceiling level in closet in main hallway. Provide additional bracing on top chords of A3 trusses were roof sheathing is stooped. Also roll block. Insuffucient bearing on at sleepers on over builds. Ok to insulate. Correction notice posted.
BLD17-03496 BLD-Final5/21/20185/21/20185/21/2018 2:37:27 PMPPASS
Phone #: ###-#### Inspection requested via web by kevin debelloy. OK for perm occ.
BLD18-01041 BLD-Final5/21/20185/21/20185/21/2018 2:07:54 PMPPASS
Chuck Phone #: ###-####. Ok for perm occ.
BLD17-03128 BLD-Framing/Rough-in5/21/20185/21/20185/21/2018 1:48:10 PMPPASS
soffit framing Phone #: ###-#### Inspection requested via web by Darrell Gogert. Steel studs for soffits ok.
BLD18-00956 BLD-Energy code compliance5/21/20185/21/20185/21/2018 1:27:31 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel solsman
BLD18-00956 BLD-Framing/Rough-in5/21/20185/21/20185/21/2018 1:27:21 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel solsman
BLD17-01088 BLD-Framing/Rough-in5/18/20185/21/20185/21/2018 12:56:01 PMAPART
Barry Phone #: ###-####. Inteior steel stud framed walls for anesthesia work room.
BLD18-00374 BLD-Energy code compliance5/17/20185/21/20185/21/2018 8:51:02 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle
BLD18-01125 BLD-Final5/18/20185/21/20185/18/2018 8:07:15 AMPCANC
Chris Brevick, homeowner: 2083773094 Phone #: ###-#### >> Inspection requested via web by BRS Permitting Inspection cancelled from web by: BRS Permitting