Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS17-00176 BLD-Conference5/30/20175/31/20175/31/2017 3:52:43 PMPDONE
Check status of structure.
MIS17-00176 DOC - Permit Finaled5/31/20175/31/20175/31/2017 3:52:30 PMPPASS
Burn out apartment units, boarded up caution tape and fenced off.
BLD16-04350 BLD-Final5/31/20175/31/20175/31/2017 3:48:46 PMPPART
Please give me a call when available to inspect, I would like to meet you onsite.
Thanks,
Drew Moorhouse
McCarter-Moorhouse
###-#### Phone #: ###-#### Inspection requested via web by Drew Moorhouse. Ok to occupy completed side. Will need to remove the thumturn from rear exit door upon completion.
BLD16-02899 BLD-Framing/Rough-in5/31/20175/31/20175/31/2017 3:31:42 PMPCANC
BLD17-00566 BLD-Framing/Rough-in5/30/20175/31/20175/31/2017 3:10:28 PMPPART
Phone #: ###-#### Inspection requested via web by John Saucerman. Interior steel stud walls for infills and new conferance rooms phase 1. provide UL listed and approved plumbing boxes for 2hr. wall.
BLD17-01145 BLD-Footing5/31/20175/31/20175/31/2017 2:06:07 PMPPASS
Jim Phone #: ###-####. Remainder of footings ok.
BLD17-00762 BLD-Framing/Rough-in5/31/20175/31/20175/31/2017 1:39:43 PMPFAIL
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Need fire place rough in inspection. Strap double top plate break at racked wall at peak and provide additional stud. Provide double 2x6 under 2ply at exterior wall in front bedroom. Correction notice posted. ok to insulate.
BLD16-04311 BLD-Footing5/30/20175/31/20175/31/2017 10:46:15 AMAPASS
Narty Phone #: ###-####
BLD16-04312 BLD-Footing5/30/20175/31/20175/31/2017 10:45:59 AMAPASS
Marty Phone #: ###-####
BLD16-04313 BLD-Foundation5/30/20175/31/20175/31/2017 10:45:44 AMAPASS
Marty Phone #: ###-####
BLD16-02899 BLD-Framing/Rough-in5/31/20175/31/20175/31/2017 10:09:12 AMAPASS
Can lights at south half of building know has 2layers of 5/8type x rock for roof/ceiling assembly, ok. north soffits double layer of 5/8 type x ok.
BLD16-03770 BLD-Energy code compliance5/30/20175/31/20175/31/2017 9:03:43 AMAPASS
Joe Phone #: ###-####
BLD17-00712 BLD-Wall Bracing5/30/20175/31/20175/31/2017 8:55:17 AMAPART
Shear // Brett Phone #: ###-####. Exterior shear walls.