Inspections for the day of: Monday, May 7, 2018.
Number of inspections: 22
Percentage of inspections complete: 95 %
Percentage of inspections not complete: 5 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-00834 BLD-Conference5/2/20185/3/2018 P 
call adam before going out would like to meet you on siteAs late as possible Phone #: 2089820822 >> Inspection requested via mobile web by Adam Junior
BLD18-00780 BLD-Final5/7/20185/7/20185/8/2018 9:51:16 AMPCANC
Please call ahead for access - Nick Phone #: ###-####
BLD17-04278 BLD-Framing/Rough-in5/4/20185/7/20185/7/2018 4:24:09 PMPNH
Jeff Phone #: ###-####
BLD18-00411 BLD-Framing/Rough-in5/7/20185/7/20185/7/2018 3:57:33 PMPFAIL
Phone #: ###-#### Inspection requested via web by Kelly Stover. Complete lateral bracing on A03 and A05 trusses. Truss engineering shows A03 truss with continous bearing on south end. A05 and A06 trusses appear to be installed in wrong places.
BLD18-00834 BLD-Final5/4/20185/7/20185/7/2018 3:36:57 PMAPASS
Adam Phone #: ###-####
BLD18-00834 DOC - Permit Finaled5/7/20185/7/20185/7/2018 3:36:48 PMPPASS
BLD18-00711 BLD-Final5/4/20185/7/20185/7/2018 3:36:37 PMANR
Devin Phone #: ###-####
BLD18-01186 BLD-Framing/Rough-in5/7/20185/7/20185/7/2018 3:35:48 PMPFAIL
Inspection requested via web by Erica Duran
MIS18-00167 BLD-Conference5/7/20185/7/20185/7/2018 3:15:24 PMPDONE
Possible work being done without permits. Some minor exterior and interior work being done. tenant does have an architect and engineer to submit plans.
BLD17-04305 BLD-Wall Bracing5/7/20185/7/20185/7/2018 2:39:00 PMPFAIL
Berry Phone #: ###-####. Install missed blocking on shop on either side of west roll up door. Nail rv garage front at 2 inches on center and install missed blocking and nail in RV bay.
BLD16-04472 BLD-Other5/7/20185/7/20185/7/2018 1:52:29 PMPPASS
Fire rated assembly at roof eave. Phone #: ###-#### Inspection requested via web by Sam Brown
BLD16-04470 BLD-Other5/7/20185/7/20185/7/2018 1:52:16 PMPPASS
Fire rated assembly at roof eave. Phone #: ###-#### Inspection requested via web by Sam Brown
BLD16-04479 BLD-Framing/Rough-in5/7/20185/7/20185/7/2018 1:52:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Sam Brown
BLD17-03922 BLD-Final5/4/20185/7/20185/7/2018 1:13:43 PMPPASS
Brandon Phone #: ###-#### or Candace ###-####. Ok for perm occ.
BLD17-03968 BLD-Final5/4/20185/7/20185/7/2018 1:13:10 PMPPASS
Garage Code is 1234 Phone #: ###-#### Inspection requested via web by Philip Yates
BLD17-03968 DOC - Permit Finaled5/7/20185/7/20185/7/2018 1:11:28 PMPPASS
BLD17-02093 BLD-Final5/6/20185/7/20185/7/2018 10:40:27 AMPCANC
Lock box on right side of house attached to gas meter. Code is 2056 Phone #: ###-#### >> Inspection requested via web by keith bucher Inspection cancelled from web by: keith bucher
BLD17-00566 BLD-Ceiling Grid Inspection5/4/20185/7/20185/7/2018 9:45:30 AMPCANC
Ceiling grid in lobby. Phone #: ###-#### >> Inspection requested via web by Shane Treasure Inspection cancelled from web by: Shane Treasure
BLD18-00955 BLD-Footing5/4/20185/7/20185/7/2018 9:25:03 AMAPEND
Byron Phone #: ###-####. INterior column pad footings. Noted city approved plans have been redlined to show (4) #4 rebar at 10 in. oc. each way. In place work has #5 bar, 3 each way per the orginal schedule. Contractor to replace as per city approved plan, or engineer of record to provide new calcs and letter showing existing work is ok.
BLD17-03632 BLD-Footing5/6/20185/7/20185/7/2018 9:21:57 AMAPART
Jim Wellman Phone #: ###-#### Inspection requested via web by Jim Wellman. Work in pogress. Will have special inspection.
BLD17-01449 BLD-Final5/7/20185/7/20185/7/2018 12:00:00 AMPCANC
Cody Phone #: ###-####
BLD18-01435 BLD-Final5/4/20185/7/20185/4/2018 12:39:55 PMPCANC
Phone #: ###-#### >> Inspection requested via web by BRS Permitting Inspection cancelled from web by: BRS Permitting