Inspections for the day of: Friday, June 28, 2019.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD19-01483 BLD-Final6/27/20196/28/20196/28/2019 5:07:14 PMPPASS
Shawn Phone #: ###-#### please call 30 min prior for access
BLD19-01483 DOC - Permit Finaled6/28/20196/28/20196/28/2019 5:07:06 PMPPASS
BLD19-01482 BLD-Final6/27/20196/28/20196/28/2019 5:06:59 PMPPASS
Shawn Phone #: ###-####- please call 30 min prior for access
BLD19-01552 BLD-Final6/27/20196/28/20196/28/2019 3:39:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher
BLD19-01552 DOC - Permit Finaled6/28/20196/28/20196/28/2019 3:39:02 PMPPASS
BLD19-01561 BLD-Final6/27/20196/28/20196/28/2019 3:04:13 PMPDONE
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher
BLD19-01561 DOC - Permit Finaled6/28/20196/28/20196/28/2019 3:04:05 PMPPASS
BLD19-02268 BLD-Other6/28/20196/28/20196/28/2019 2:16:37 PMPPASS
Mfg home block ; tie inspection. Thank you!! Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
BLD19-01506 BLD-Other6/28/20196/28/20196/28/2019 1:43:27 PMPPASS
block and tie // Linn Phone #: ###-####
BLD19-02056 BLD-Final6/27/20196/28/20196/28/2019 1:43:03 PMPDONE
Final Phone #: ###-#### Inspection requested via web by Joshua Adams
BLD19-02056 DOC - Permit Finaled6/28/20196/28/20196/28/2019 1:42:46 PMPPASS
All work appeared to be done in accordance with local codes and ordinances.
BLD19-01162 BLD-Final6/27/20196/28/20196/28/2019 1:41:47 PMPPASS
Tim Phone #: ###-####
BLD19-01162 DOC - Permit Finaled6/28/20196/28/20196/28/2019 1:41:28 PMPPASS
BLD19-01444 BLD-Final6/28/20196/28/20196/28/2019 1:41:05 PMPFAIL
Key to unit in lock box located in mailbox near door. Code is 2805 Phone #: ###-#### Inspection requested via web by Chad Aland. A mech. permit is required for the ventalation fan that has been installed. noted no framing inspection has been conducted on new framing for restroom. Miiror and grab bars mounted in correctly to walls. A correction notice has been issued.
BLD17-02261 BLD-Wall cover6/27/20196/28/20196/28/2019 12:08:02 PMAPASS
2nd and 3rd Floor Corridor ceiling inspections for cover. Sections A and D to end of corridors. Phone #: ###-#### Inspection requested via web by JT Turner. 2nd. and 3rd floor north and south corridor lids in Areas A and D ok for cover.
BLD18-03990 BLD-Other6/27/20196/28/20196/28/2019 11:27:34 AMADEFR
Brian- inspection for inwall rebar PCLINE Phone #: ###-####. Pending special inspection.
BLD18-04470 BLD-Wall cover6/28/20196/28/20196/28/2019 11:04:32 AMACANC
looking for insulation inspection - by offered listings, not sure if it''s this or
"energy compliance" Thank you Phone #: ###-#### Inspection requested via web by Gary Band
BLD18-04470 BLD-Energy code compliance6/28/20196/28/20196/28/2019 11:04:22 AMAPASS
looking for insulation inspection - by offered listings, not sure if it''s this or
"wall cover" Thank you Phone #: ###-#### Inspection requested via web by Gary Band
BLD06-02322 BLD-Framing/Rough-in6/27/20196/28/20196/28/2019 10:48:18 AMAPASS
second floor corridor, area B // Lee Phone #: ###-####. 2nd. floor corridors area B ok to rock lid.
BLD19-00250 BLD-Wall cover6/27/20196/28/20196/28/2019 10:07:00 AMAPASS
units 135 and 136, 233, 234, 235, 236 // Justin Phone #: ###-####
BLD19-00397 BLD-Final6/26/20196/28/20196/28/2019 9:39:36 AMAPASS
victor Phone #: ###-####
BLD19-00397 DOC - Permit Finaled6/28/20196/28/20196/28/2019 9:39:27 AMPPASS
BLD19-01926 BLD-Foundation6/28/20196/28/20196/28/2019 9:27:08 AMAPART
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
BLD18-03240 BLD-Energy code compliance6/27/20196/28/20196/28/2019 9:19:18 AMAPASS
Coty Phone #: ###-####
BLD18-03240 BLD-Framing/Rough-in6/27/20196/28/20196/28/2019 9:19:04 AMAPASS
Coty Phone #: ###-####
BLD19-00803 BLD-Framing/Rough-in6/27/20196/28/20196/28/2019 8:59:48 AMAFAIL
Plans will be at the fireplace! Thanks Mike! Scott Phone #: ###-#### Inspection requested via web by Scott Zierler. Install straps for portal frames. Complete fire blockingat fir downs in main hallway by front door, both sides. Justify notched truss at bearing. (F3 truss). Roll block F1,F2,and F3 trusses, both sides. Nail C3 triple ply truss per the engineering and add stud under bearing. Complete lateral bracing on A4, A4A, A5, A6, A7 trusses. Correction notice posted. ok to insulate.
BLD19-00803 BLD-Energy code compliance6/27/20196/28/20196/28/2019 8:56:45 AMACANC
Thank you! Phone #: ###-#### Inspection requested via web by Scott Zierler
BLD19-00630 BLD-Final6/28/20196/28/20196/28/2019 12:00:00 AMPCANC
Cecil Phone #: ###-####