MIS18-00345
| MIS-Aging Inspection | 7/23/2019 | 7/23/2019 | 7/23/2019 4:21:04 PM | | DEFR |
|
|
|
BLD19-01383
| BLD-Energy code compliance | 7/21/2019 | 7/23/2019 | 7/23/2019 3:46:48 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD18-02281
| BLD-Final | 7/22/2019 | 7/23/2019 | 7/23/2019 3:18:46 PM | P | NR |
|
|
Mark Phone #: ###-####. Issues with door hardware. Waiting for plan review. Will need to reschedule.
|
BLD18-02407
| BLD-Footing | 7/19/2019 | 7/23/2019 | 7/23/2019 3:04:54 PM | P | CANC |
|
|
rebar - after 2 pm // Doug Phone #: ###-####
|
BLD18-02407
| BLD-Foundation | 7/23/2019 | 7/23/2019 | 7/23/2019 3:04:35 PM | P | FAIL |
|
|
rebar - after 2 pm // Doug Phone #: ###-####. Hairpins not installed around anchor bolts. #3 ties do not conform to ACI standards. Ties are not continous and missing hooks. Contractor noted that this rebar was donated. Noted to contractor that the ties still need to meet ACI.
|
BLD18-01425
| BLD-Conference | 7/23/2019 | 7/23/2019 | 7/23/2019 2:27:23 PM | P | PEND |
|
|
zack Phone #: ###-####. Will be ok for Temp occ. once life/safety has given a temp occ. and the building official has approved the removal of the added gate from the court yard for proper egress width.
|
BLD19-00726
| BLD-Foundation | 7/23/2019 | 7/23/2019 | 7/23/2019 2:21:14 PM | P | PASS |
|
|
Tom Phone #: ###-####. South exterior stemwall, conveyor pit floor.
|
BLD19-01565
| BLD-Framing/Rough-in | 7/23/2019 | 7/23/2019 | 7/23/2019 1:27:48 PM | P | PART |
|
|
Wayne-if you call and no one answers just leave a message and he''ll get back to you Phone #: ###-#### Interior framing ok. Needs to get plumbing permit and get rough in inspection then complete air seal.
|
MIS19-00202
| BLD-Conference | 7/17/2019 | 7/23/2019 | 7/23/2019 1:27:00 PM | A | DONE |
|
|
Follow up... Per contractor (Ryan Curtis ###-####) Theyare in the process of applying for an administrative zoning alternate.
|
BLD18-04521
| BLD-Footing | 7/22/2019 | 7/23/2019 | 7/23/2019 11:12:25 AM | A | PART |
|
|
Concrete at 1230 // bob Phone #: ###-####. Perimeter footings and column pad footings. Will have special inspection. Noted several areas were rebar does not have the 3 inch minimum clearance required. Special inspector to verify 3inch min. clearance prior to concrete placement.
|
BLD19-01353
| BLD-Other | 7/22/2019 | 7/23/2019 | 7/23/2019 10:47:41 AM | A | PASS |
|
|
fire wall // Kenny Phone #: ###-####. 1st. floor fire walls ok.
|
BLD19-01352
| BLD-Other | 7/22/2019 | 7/23/2019 | 7/23/2019 10:47:25 AM | A | PASS |
|
|
fire wall // Kenny Phone #: ###-####. 1st. floor fire walls ok.
|
BLD19-01351
| BLD-Other | 7/22/2019 | 7/23/2019 | 7/23/2019 10:47:10 AM | A | PASS |
|
|
fire wall // Kenny Phone #: ###-####. 1st. floor fire walls ok.
|
BLD19-01350
| BLD-Other | 7/22/2019 | 7/23/2019 | 7/23/2019 10:46:53 AM | A | PASS |
|
|
fire wall // Kenny Phone #: ###-####. 1st. floor fire walls ok.
|
BLD19-01349
| BLD-Other | 7/22/2019 | 7/23/2019 | 7/23/2019 10:46:36 AM | A | PASS |
|
|
fire wall // Kenny Phone #: ###-####. 1st. floor fire walls ok.
|
BLD19-01348
| BLD-Other | 7/22/2019 | 7/23/2019 | 7/23/2019 10:46:20 AM | A | PASS |
|
|
fire wall // Kenny Phone #: ###-####. 1st. floor fire walls ok.
|
BLD19-01347
| BLD-Other | 7/22/2019 | 7/23/2019 | 7/23/2019 10:46:03 AM | A | PASS |
|
|
fire wall // Kenny Phone #: ###-####. 1st. floor fire walls ok.
|
BLD19-01807
| BLD-Framing/Rough-in | 7/22/2019 | 7/23/2019 | 7/23/2019 10:33:05 AM | A | PASS |
|
|
|
BLD19-02142
| BLD-Footing | 7/22/2019 | 7/23/2019 | 7/23/2019 10:18:03 AM | A | FAIL |
|
|
Mark or Kevin ###-#### Phone #: ###-####. Engineers calls for 36 inch deep hold down piers. In place piers are only 24 inch deep.
|
BLD19-00808
| BLD-Final | 7/22/2019 | 7/23/2019 | 7/23/2019 9:48:41 AM | A | PASS |
|
|
Garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-00808
| DOC - Permit Finaled | 7/23/2019 | 7/23/2019 | 7/23/2019 9:48:34 AM | P | PASS |
|
|
|
BLD19-00808
| BLD-Blower Door Test Results | 7/23/2019 | 7/23/2019 | 7/23/2019 9:48:23 AM | A | DONE |
|
|
5.2
|
BLD19-00495
| BLD-Final | 7/22/2019 | 7/23/2019 | 7/23/2019 9:27:13 AM | A | PASS |
|
|
Garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-00495
| DOC - Permit Finaled | 7/23/2019 | 7/23/2019 | 7/23/2019 9:26:59 AM | P | PASS |
|
|
All issues were resolved.
|
BLD19-00807
| BLD-Final | 7/22/2019 | 7/23/2019 | 7/23/2019 9:21:29 AM | A | PASS |
|
|
Garage door code is 2468 Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD19-00807
| DOC - Permit Finaled | 7/23/2019 | 7/23/2019 | 7/23/2019 9:21:18 AM | P | PASS |
|
|
|
BLD19-00807
| BLD-Blower Door Test Results | 7/23/2019 | 7/23/2019 | 7/23/2019 9:17:43 AM | A | DONE |
|
|
4.7
|