Inspections for the day of: Wednesday, August 5, 2020.
Number of inspections: 34
Percentage of inspections complete: 85 %
Percentage of inspections not complete: 15 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-02068 BLD-Final8/5/20208/5/20208/5/2020 5:42:25 PMPPEND
Ok with video/photo .. after 1 ... Diana Phone #: ###-####. Video inspection pass. Will drop off letter of completion tomorrow in mailbox.
BLD19-02442 BLD-Concrete8/4/20208/5/20208/5/2020 3:30:57 PMPPASS
Rebar inspection for a slab on grade. If possible, please make this inspection as late in the day as possible, thanks. Phone #: ###-#### Inspection requested via web by David Booth. Rebar for interior slab on grade and column pad footings in seperator room.
BLD20-01120 BLD-Framing/Rough-in8/5/20208/5/20208/5/2020 2:53:15 PMPPASS
Screened- Kim Phone #: ###-####. Interior steel stud framed walls ok. Hardlids also ok pending fire sprinkler rough in inspection.
BLD19-03734 BLD-Concrete8/5/20208/5/20208/5/2020 2:35:45 PMPPASS
Non-Structural building interior slab on grade ready for placement Phone #: ###-#### Inspection requested via web by Dan Murrer
BLD19-03734 BLD-Energy code compliance8/5/20208/5/20208/5/2020 2:35:32 PMPPASS
Metal Building Simple Saver Insulation System Complete Phone #: ###-#### Inspection requested via web by Dan Murrer
BLD20-01900 BLD-Foundation8/5/20208/5/20208/5/2020 2:07:35 PMPPART
Gaude -*/Screened*/ Phone #: ###-####
BLD20-01603 BLD-Footing8/4/20208/5/20208/5/2020 2:07:10 PMPPASS
Dane - Screened Phone #: ###-####
BLD20-01608 BLD-Footing8/4/20208/5/20208/5/2020 2:06:59 PMPPASS
Dane - Screened Phone #: ###-####
BLD20-01609 BLD-Footing8/4/20208/5/20208/5/2020 2:06:48 PMPPASS
Dane - Screened Phone #: ###-####
BLD20-01610 BLD-Footing8/4/20208/5/20208/5/2020 2:06:35 PMPPASS
Dane - Screened Phone #: ###-####
BLD20-01611 BLD-Footing8/4/20208/5/20208/5/2020 2:06:20 PMPPASS
Dane - Screened Phone #: ###-####
BLD20-01318 BLD-Framing/Rough-in8/5/20208/5/20208/5/2020 1:43:00 PMPPASS
Phone #: ###-#### Inspection requested via web by Rustin Ray
BLD20-01858 BLD-Footing8/4/20208/5/20208/5/2020 12:03:14 PMAPASS
Jason - */Screened*/ Phone #: ###-####
BLD20-00093 BLD-Wall Bracing8/4/20208/5/20208/5/2020 11:39:36 AMAFAIL
*Screened* Shear wall - Steve Phone #: ###-####. Install missing fasteners.
BLD20-00725 BLD-Final8/4/20208/5/20208/5/2020 11:25:50 AMANR
Kyle *screened* Phone #: ###-####. Exterior of building not yet compleed.
BLD20-00308 BLD-Final8/4/20208/5/20208/5/2020 11:25:15 AMAPART
Kyle *screened* Phone #: ###-####. OK for temp occ. Needs to revise scope of work or submit aditional plans for occupancy. Provide final letter from special inspection agency and RFI from engineer for east footing.
BLD19-01080 BLD-Footing8/4/20208/5/20208/5/2020 10:46:41 AMAPASS
Mike -*/Screened*/ Phone #: ###-####
BLD20-02068 BLD-Footing8/4/20208/5/20208/5/2020 10:27:52 AMAPASS
FIRST AM inspection requested if at all possible please. Footings ready day prior. Phone #: ###-#### Inspection requested via web by David Dexter
BLD20-00026 BLD-Energy code compliance8/3/20208/5/20208/5/2020 10:12:55 AMAPASS
Inspection requested for Exterior Wall Inspection to Cover Phone #: ###-#### Inspection requested via web by todd smock. Ok to sheet rock exterior walls only.
BLD20-00026 BLD-Framing/Rough-in8/5/20208/5/20208/5/2020 10:12:21 AMAPART
Inspection requested for Exterior Wall Inspection to Cover Phone #: ###-#### Inspection requested via web by todd smock. Needs to complete lateral bracing on trusses, fire block furred walls and provide engineering from truss co. showing addditional load on bottom chord for added soffits ok.
BLD19-03643 BLD-Final8/4/20208/5/20208/5/2020 9:42:44 AMAPEND
Tyler- */Screened*/ Phone #: ###-####. Needs to provide ignition barrier or DC coating to achoeve ignition barrier per the ESR report.
BLD18-01027 BLD-Framing/Rough-in6/24/20208/5/20208/5/2020 9:13:47 AMACANC
BLD20-00427 BLD-Framing/Rough-in8/4/20208/5/20208/5/2020 9:13:15 AMAFAIL
SCREEENED // Kenny Phone #: ###-####. Complete lateral bracing on A02 trusses. Complete all fire caulking. Install all missed fasteners on fire wall and all missing pieces of sheet rock on firewalls. Pending mech. rough in inspection.
BLD20-00426 BLD-Framing/Rough-in8/4/20208/5/20208/5/2020 9:12:57 AMAFAIL
SCREEENED // Kenny Phone #: ###-####. Complete lateral bracing on A02 trusses. Complete all fire caulking. Install all missed fasteners on fire wall and all missing pieces of sheet rock on firewalls. Pending mech. rough in inspection.
BLD20-00425 BLD-Framing/Rough-in8/4/20208/5/20208/5/2020 9:12:37 AMAFAIL
SCREEENED // Kenny Phone #: ###-####. Complete lateral bracing on A02 trusses. Complete all fire caulking. Install all missed fasteners on fire wall and all missing pieces of sheet rock on firewalls. Pending mech. rough in inspection.
BLD20-00424 BLD-Framing/Rough-in8/4/20208/5/20208/5/2020 9:12:16 AMAFAIL
SCREEENED // Kenny Phone #: ###-####. Complete lateral bracing on A02 trusses. Complete all fire caulking. Install all missed fasteners on fire wall and all missing pieces of sheet rock on firewalls. Pending mech. rough in inspection.
BLD20-00423 BLD-Framing/Rough-in8/4/20208/5/20208/5/2020 9:11:52 AMAFAIL
SCREEENED // Kenny Phone #: ###-####. Complete lateral bracing on A02 trusses. Complete all fire caulking. Install all missed fasteners on fire wall and all missing pieces of sheet rock on firewalls. Pending mech. rough in inspection.
BLD20-00422 BLD-Framing/Rough-in8/4/20208/5/20208/5/2020 9:09:06 AMAFAIL
SCREEENED // Kenny Phone #: ###-####. Complete lateral bracing on A02 trusses. Complete all fire caulking. Install all missed fasteners on fire wall and all missing pieces of sheet rock on firewalls. Pending mech. rough in inspection.
BLD20-00371 BLD-Framing/Rough-in8/4/20208/5/20208/5/2020 9:07:50 AMAFAIL
SCREEENED // Kenny Phone #: ###-####. Complete lateral bracing on A02 trusses. Complete all fire caulking. Install all missed fasteners on fire wall and all missing pieces of sheet rock on firewalls. Pending mech. rough in inspection.
BLD19-02935 BLD-Aging Inspection8/5/20208/5/2020   
MIS17-00353 MIS-Aging Inspection8/5/20208/5/2020   
MIS17-00429 MIS-Aging Inspection8/5/20208/5/2020   
MIS18-00007 MIS-Aging Inspection8/5/20208/5/2020   
MIS18-00035 MIS-Aging Inspection8/5/20208/5/2020