Inspections for the day of: Friday, August 9, 2019.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD19-01362 BLD-Energy code compliance8/9/20198/9/20198/9/2019 4:32:47 PMPPASS
LARRY Phone #: ###-####. . Insulation for 1hr. walls first floor.
BLD19-01363 BLD-Energy code compliance8/9/20198/9/20198/9/2019 4:32:30 PMPPASS
LARRY Phone #: ###-####. . Insulation for 1hr. walls first floor.
BLD19-01360 BLD-Energy code compliance8/9/20198/9/20198/9/2019 4:32:12 PMPPASS
LARRY Phone #: ###-####. . Insulation for 1hr. walls first floor.
BLD19-01361 BLD-Energy code compliance8/9/20198/9/20198/9/2019 4:31:55 PMPPASS
LARRY Phone #: ###-####. . Insulation for 1hr. walls first floor.
BLD19-01358 BLD-Energy code compliance8/9/20198/9/20198/9/2019 4:31:38 PMPPASS
LARRY Phone #: ###-####
BLD19-01359 BLD-Energy code compliance8/9/20198/9/20198/9/2019 4:31:27 PMPPASS
LARRY Phone #: ###-####. . Insulation for 1hr. walls first floor.
BLD19-01355 BLD-Energy code compliance8/9/20198/9/20198/9/2019 4:31:12 PMPPASS
LARRY Phone #: ###-####. Insulation for 1hr. walls first floor.
BLD19-01384 BLD-Wall Bracing8/7/20198/9/20198/9/2019 3:40:13 PMPPASS
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD18-02176 BLD-Other8/9/20198/9/20198/9/2019 3:18:56 PMPPASS
fire wall // nicho Phone #: ###-####. 5/8 sheet rock on underside of decking.
BLD19-02092 BLD-Final8/9/20198/9/20198/9/2019 2:43:23 PMPPASS
Please call ###-#### when on the way. Thanks!! Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
BLD19-02092 DOC - Permit Finaled8/9/20198/9/20198/9/2019 2:43:15 PMPPASS
BLD17-04462 BLD-Final8/8/20198/9/20198/9/2019 2:16:11 PMPFAIL
Garage code 0813 Phone #: ###-#### Inspection requested via web by Scott Zierler. Provide Blower door test results. everything else ok.
BLD19-01926 BLD-Framing/Rough-in8/8/20198/9/20198/9/2019 2:14:54 PMPFAIL
Gotti Phone #: ###-####. Install bolts on hold downs on RV bay. Provide approved fix for A2 truss heal. Ik to insulate. Correction notice posted.
BLD19-01682 BLD-Other8/8/20198/9/20198/9/2019 11:54:37 AMACANC
Seepage bed has been excavated to free draining material. Need any city inspection if required. Phone #: ###-#### Inspection requested via web by Shawn Plimmer
BLD19-01371 BLD-Final8/8/20198/9/20198/9/2019 10:23:49 AMAPASS
Todd Phone #: ###-####
BLD19-01371 FIRE-Final Inspection8/9/20198/9/20198/9/2019 10:23:40 AMAPASS
Todd Phone #: ###-####
ESC18-01203 Site Final8/9/20198/9/20198/9/2019 10:00:59 AMADONE
ESC18-01203 DOC - Permit Finaled8/9/20198/9/20198/9/2019 10:00:52 AMPPASS
BLD18-03022 BLD-Final8/8/20198/9/20198/9/2019 10:00:42 AMAPASS
Gate Code: #9898
Garage Code: 6365 Phone #: ###-#### Inspection requested via web by Jessica Bradley
BLD18-03022 DOC - Permit Finaled8/9/20198/9/20198/9/2019 10:00:33 AMPPASS
BLD18-03022 BLD-Blower Door Test Results8/9/20198/9/20198/9/2019 9:59:57 AMADONE
4.4
BLD19-02092 BLD-Final8/8/20198/9/20198/9/2019 9:38:25 AMANR
Please call ###-#### when on the way. Will be onsite in park and would like to meet with you during inspection. Thanks!! Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
BLD19-02010 BLD-Footing8/8/20198/9/20198/9/2019 9:09:27 AMAFAIL
Sergio Phone #: ###-####. Approved plans shows duplex 1hr. wall seoeration, per scope of work, townhouses are being constructed, which require a 2hr. seperation. Plans to be resubmitted.
BLD19-02007 BLD-Footing8/8/20198/9/20198/9/2019 9:09:06 AMAFAIL
Sergio Phone #: ###-####. Approved plans shows duplex 1hr. wall seoeration, per scope of work, townhouses are being constructed, which require a 2hr. seperation. Plans to be resubmitted.
BLD19-02074 BLD-Foundation8/8/20198/9/20198/9/2019 8:33:32 AMAPART
Erme-stem wall Phone #: ###-####