Inspections for the day of: Friday, January 31, 2020.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Page
TitleFIRE INSPECTOR
Phone #208-914-5431
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR19-00559 INSP-Final Inspection1/28/20201/31/20201/31/2020 3:18:12 PMPPASS
Final fire alarm inspection for scope of work is complete.

Phone #: ###-#### Inspection requested via web by Neal Timmerman
FIR15-00122 INSP-Final Inspection1/31/20201/31/20201/31/2020 3:17:42 PMPPASS
Final inspection was completed by Lee Meridith on 06APR2015, permit is finaled.
BLD19-03650 FIRE-Final Inspection1/31/20201/31/20201/31/2020 2:32:22 PMPPASS
Permenant doors have been installed, final life fire safety inspection for scope of work is complete.

David Phone #: ###-####
BLD19-04225 FIRE-Final Inspection1/31/20201/31/20201/31/2020 12:23:52 PMPPART
Partial final inspection for life fire safety complete, a minor fire alarm modification was required, hotel fire panel is what provides notification to the fire alarms in area of work, fire alarm inspection for the 1 strobe addition will be completed on 05FEB2020. No fire sprinkler modifications, fire extinguishers are placed with current inspection tags. TCO authorized for 14 days per conversation with Joe Bruce, Fire Section Supervisor. After fire alarm inspection is inspected and finaled this permit can be signed off for life fire safety. Chest freezer will be relocated as discussed.

Justin Phone #: ###-####
BLD19-04672 FIRE-Final Inspection1/30/20201/31/20201/31/2020 12:14:50 PMAPASS
No fire sprinkler modifications, no fire alarm modifications, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for scope of work complete, signatures provided on permit sign off card.

Angie Phone #: ###-####
BLD19-01828 FIRE-Conference1/31/20201/31/20201/31/2020 11:48:01 AMADONE
Spoke with GC about level 4 insulation for sprinkler piping. According to the GC the roof has an insulation value of R-30, as shown on the city approved fire sprinkler drawings a minimum of R-38 is required, more insulation will need to be provided and installed per detail on the fire sprinkler approved drawings. Cover will not be authorized on the level 4 fire sprinkler piping until a minimum combined value of R-38 is provided.
FIR19-00702 INSP-Sprinkler Rough-in1/31/20201/31/20201/31/2020 11:42:35 AMAPART
Rough to cover inspection for levels 1, 2 and 3 complete, levels 1,2 and 3 suite rooms approved for cover, city approved plans are notated with red ink areas approved for cover, corridor heads to be cut in after ceiling grid is installed. Rough in inspection for level 4 complete, tenting not installed at time of inspection. According to GC the roof has an R-30 rating, as shown on city approved drawings R-38 is minimum R value to be compliant with approved drawings, cover is not approved for level 4.

1st, 3rd, 4th floor rough/tenting. Call James before heading out. Phone #: ###-#### Inspection requested via web by Anthony Minichiello
BLD18-03423 FIRE-Final Inspection1/31/20201/31/20201/31/2020 10:41:01 AMPPASS
No fire sprinkler modifications, fire alarm inspection is complete, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for area of work complete.

Erik Phone #: ###-####
FIR19-00874 INSP-Final Inspection1/30/20201/31/20201/31/2020 10:38:45 AMAPASS
Final fire alarm inspection for area of work complete.

Contact is Dan. Phone #: ###-#### Inspection requested via web by Morgan Ahten
FIR19-00873 INSP-Final Inspection1/30/20201/31/20201/31/2020 10:38:26 AMAPASS
Final fire alarm inspection for area of work complete.

Contact is Dan. Phone #: ###-#### Inspection requested via web by Morgan Ahten
FIR19-00861 INSP-Final Inspection1/30/20201/31/20201/31/2020 10:38:04 AMAPASS
Final fire alarm inspection for area of work complete.

Contact is Dan. Phone #: ###-#### Inspection requested via web by Morgan Ahten
FIR19-00932 INSP-Final Inspection1/28/20201/31/20201/31/2020 9:57:18 AMAPART
Fire alarm inspection is compliant with NFPA72, as-builts need to be submitted, approved and fees paid before permit can be finaled.

Please start Final at 9:30 as this system is connected to the Hampton Inn hotel and it can''t go off past 10:00 AM. Eric will be on site. Phone #: ###-#### Inspection requested via web by Fire Scheduler
FIR19-00934 INSP-Final Inspection1/28/20201/31/20201/31/2020 8:56:49 AMAFAIL
Inspection request was not coordinated with inspector, start time for inspector is 8AM unless approved by the fire section supervisor for a 7AM inspection time, as stated before on past inspections, 7AM inspection time needs to be coordinated with the inspector and approved by the fire section supervisor per notification to the fire section supervisor by the inspector.

Building is occupied - 7 am schedule Phone #: ###-#### Inspection requested via web by Kristin Dolan
FIR19-00858 INSP-Final Inspection1/30/20201/31/20201/31/2020 8:50:33 AMAPART
Final fire alarm inspection for area of work has been completed, as-builts to be sent in for in duct smoke detector relocations as well as device address changes. Permit can be signed off as finaled after as-builts are received, approved and fees are paid.

Phone #: 2088990672 >> Inspection requested via mobile web by Josiah
FIR19-00841 INSP-Final Inspection1/29/20201/31/20201/31/2020 8:49:05 AMAPASS
Final hood suppression system inspection complete.

Phone #: 2084777315 >> Inspection requested via mobile web by Matt Robison
FIR19-00842 INSP-Final Inspection1/29/20201/31/20201/31/2020 8:48:13 AMAPASS
Final hood suppression system inspection complete.

Phone #: 2084777315 >> Inspection requested via mobile web by Matt Robison