Inspections for the day of: Thursday, October 18, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Page
TitleFIRE INSPECTOR
Phone #208-914-5431
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-02099 FIRE-Final Inspection10/17/201810/18/201810/18/2018 1:32:31 PMPFAIL
Fire panel was showing troubles at time of inspection, fire alarm system needs to be repaired and panel showing normal before life fire safety inspection is perfromed. Kitchen and dining room were in use at time of inspection, mentioned areas have not had final inspections completed, kitchen staff was informed to cease operation in areas were inspections need to be completed, no occupancy in areas of work is allowed until final inspections are complete and a C of O has been issued.

Phone #: ###-#### Inspection requested via web by Steve Jones
FIR18-00662 INSP-Final Inspection10/17/201810/18/201810/18/2018 1:29:43 PMPFAIL
Troubles on fire alarm panel need to be repaired before fire alarm permit in scope of work can be inspected and finaled, inspection will result in a failure until fire alarm system is repaired and panel is showing normal.



Please call ahead. Phone #: ###-#### Inspection requested via web by Gary Gambino
FIR18-00406 INSP-Final Inspection10/18/201810/18/201810/18/2018 1:26:36 PMPPASS
Final fire sprinkler inspection for area of work complete.

DON FORESTER Phone #: ###-#### Inspection requested via web by Brodie Stenquist
FIR18-00598 INSP-Final Inspection10/17/201810/18/201810/18/2018 1:25:26 PMPPASS
Final fire sprinkler inspection for area of work complete.

Rick Phone #: ###-####
BLD18-01325 FIRE-Final Inspection10/17/201810/18/201810/18/2018 1:24:43 PMAFAIL
FIR permit for associated fire alarm modifications (FIR18-00483) in area of work needs to be finaled before life fire safety inspection can be completed.

Kelly Phone #: ###-####
BLD17-00634 FIRE-Final Inspection10/17/201810/18/201810/18/2018 1:22:35 PMAPASS
Previoulsy noted items have been corrected, final life fire safety inspection for this permit complete.

for temp // Ed Johnston Phone #: ###-####
BLD18-02992 FIRE-Final Inspection10/17/201810/18/201810/18/2018 10:18:15 AMAPASS
Previously noted items have been corrected, no fire sprinkler modifications, no fire alarm modifications, fire extinguisher is mounted in discussed location, hood suppression system annual inspection is complete, final life fire safety inspection for area of work complete.

An Phone #: ###-####
FIR18-00770 INSP-Sprinkler Rough-in10/17/201810/18/201810/18/2018 9:58:19 AMAPASS
Rough to cover inspection for area of work complete, sidewall heads shown on plan top cover under roll up doors have been deleted, heads are not required, door does not roll back more than 48 inches.

Plans are on the counter behind the bar. Phone #: ###-#### Inspection requested via web by Sam Ball
BLD15-03857 FIRE-Final Inspection10/17/201810/18/201810/18/2018 9:47:35 AMAPASS
Final life fire safety inspection for area of work complete.

Zack Phone #: ###-####
BLD16-03010 FIRE-Final Inspection10/17/201810/18/201810/18/2018 9:47:06 AMAPASS
Final life fire safety inspection for area of work complete.

Zack Phone #: ###-####
BLD14-03120 FIRE-Final Inspection10/18/201810/18/201810/18/2018 9:46:31 AMAFAIL
A fire alarm permit will be required for fire alarm modifications in area to be code compliant. Provide fire alarm modifications as discussed.
BLD14-03120 FIRE-Supply Line Hydro10/17/201810/18/201810/18/2018 9:44:08 AMACANC
This request is cancelled, inspection should have been a life fire safey inspection for area of work.

Zack Phone #: ###-####
FIR17-00612 INSP-Sprinkler Rough-in10/17/201810/18/201810/18/2018 8:42:15 AMAFAIL
All combustible materials in over-builds and concealed spaces requires fire sprinkler coverage per NFPA13, fire sprinklers will required in un-protected areas as discussed, if areas discussed are left un-protected then inspection requests for this project will result ikn a failure.

Mike Bierman is the contact for this RTC inspection. Thank you for your help. Phone #: ###-#### Inspection requested via web by Stan Beus
BLD18-03431 FIRE-Final Inspection10/17/201810/18/201810/18/2018 8:38:48 AMAPASS
Previously noted items have been corrected, final life fire safety inspection for area of work complete.

Ken Phone #: ###-####