FIR18-00101
| INSP-Sprinkler Rough-in | 2/14/2018 | 2/14/2018 | 2/14/2018 3:01:33 PM | P | PASS |
|
|
Rough to cover inspection for overhead fire sprinkler piping in area of work complete, area of work approved for cover.
|
FIR17-00460
| INSP-Supply line flush | 2/13/2018 | 2/14/2018 | 2/14/2018 2:33:38 PM | P | DONE |
|
|
Undergorund main line flush complete.
|
FIR17-00461
| INSP-Supply line flush | 2/13/2018 | 2/14/2018 | 2/14/2018 2:33:13 PM | P | DONE |
|
|
Undergorund main line flush complete.
|
FIR17-00458
| INSP-Supply line flush | 2/13/2018 | 2/14/2018 | 2/14/2018 2:32:52 PM | P | DONE |
|
|
Undergorund main line flush complete.
|
FIR17-00446
| INSP-Supply line flush | 2/13/2018 | 2/14/2018 | 2/14/2018 2:32:34 PM | P | PASS |
|
|
Undergorund main line flush complete.
|
FIR17-00448
| INSP-Supply line flush | 2/13/2018 | 2/14/2018 | 2/14/2018 2:32:16 PM | P | DONE |
|
|
Undergorund main line flush complete.
|
FIR17-00459
| INSP-Sprinkler Rough-in | 2/13/2018 | 2/14/2018 | 2/14/2018 2:31:43 PM | P | PASS |
|
|
Rough to cover inspection for overhead fire sprinkler piping/tenting complete, approved for cover.
|
FIR17-00447
| INSP-Supply line flush | 2/13/2018 | 2/14/2018 | 2/14/2018 2:27:16 PM | P | CANC |
|
|
Flush could not be completed, possible issue with valve or piping, request is cancelled.
|
FIR17-00612
| INSP-Sprinkler Rough-in | 2/13/2018 | 2/14/2018 | 2/14/2018 10:54:16 AM | A | PART |
|
|
Partial rough to cover inspection for scope of work complete, west building inspected and approved for cover. FDC will need to be relocated due to access issues from daycare on northside of building.
|
FIR17-00752
| INSP-Sprinkler Rough-in/Hydro | 2/13/2018 | 2/14/2018 | 2/14/2018 10:09:25 AM | A | PASS |
|
|
Rough to cover inspection for overhead fire sprinkler piping in area of work complete, approved for cover.
|
BLD17-04195
| FIRE-Final Inspection | 2/13/2018 | 2/14/2018 | 2/14/2018 8:53:46 AM | A | PASS |
|
|
No fire sprinklers, no fire alarm modifications required, fire extinguishers are in place with current inspection tags. Final life fire safety inspection for area of work complete.
|
BLD17-02841
| FIRE-Final Inspection | 2/13/2018 | 2/14/2018 | 2/14/2018 8:52:45 AM | A | FAIL |
|
|
Room addition is a conference/training room, fire alarm modifications are required.
|
BLD17-02615
| FIRE-Final Inspection | 2/13/2018 | 2/14/2018 | 2/14/2018 8:51:42 AM | A | PASS |
|
|
Fire sprinkler inspection complete, no fire alarm modifications, fire extinguishers are in common areas with current inspection tags. Final life fire safety inspection for area of work complete.
|
FIR17-00464
| INSP-Final Inspection | 2/14/2018 | 2/14/2018 | 2/14/2018 8:50:47 AM | A | PASS |
|
|
Final fire sprinkler inspection for area of work complete.
|
FIR17-00752
| INSP-Sprinkler Rough-in/Hydro | 2/13/2018 | 2/14/2018 | 2/13/2018 1:17:20 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Matthew Lewis Inspection cancelled from web by: Matthew Lewis
|