Inspections for the day of: Friday, January 17, 2020.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00209 Pressure Test1/16/20201/17/20201/17/2020 4:00:29 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- 20lb gas pressure test ok
- tagged meter location
MEC20-00199 Final1/16/20201/17/20201/17/2020 3:17:08 PMPPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney
- furnace only ok
MEC20-00220 Final1/17/20201/17/20201/17/2020 3:05:53 PMPFAIL
GAS FURNACE REPLACEMENT HOME OWNER HOME. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
- indoor coil needs a wet switch installed on secondary and pump needs safety switch wired in.
- furnace co ok
MEC19-05570 Final1/17/20201/17/20201/17/2020 2:23:42 PMPFAIL
Jasper Hoff Phone #: ###-#### Inspection requested via web by Ted Dumont Inc.
- All returns in new space need to be ducted. Other spaces next to suite 330 are ducted returns currently. If space above ceiling is going to become an open return plenum engineer design is needed.
MEC19-05040 Final1/17/20201/17/20201/17/2020 1:31:36 PMPPASS
call for access // bill ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
- outdoor fireplace final ok
MEC19-00240 Final1/16/20201/17/20201/17/2020 11:39:15 AMAPART
Final - Area A. Contact: Robert Church ###-####. Phone #: ###-#### Inspection requested via web by Brent Lacy
Temp final ok on area A units 103,104,105,106, lobby
203, 204, 205,
302 and parking garage
MEC19-01155 Final1/16/20201/17/20201/17/2020 11:38:14 AMAPART
Can you come around 11am? Temp occupancy Area A and Garage level. Antonio is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist
Temp final ok on area A units 103,104,105,106, lobby
203, 204, 205,
302 and parking garage
MEC19-05570 Final1/16/20201/17/20201/17/2020 10:23:48 AMAFAIL
Please contact Jasper with access questions. General Contractor is located on site and we can have them open the suite for you. Phone #: ###-#### Inspection requested via web by Ted Dumont Inc.
- called contract in notes no answer
- no access to ceiling and no ladder
MEC20-00207 DOC - Permit Finaled1/17/20201/17/20201/17/2020 10:22:24 AMPPASS
final ok
MEC20-00207 Pressure Test1/16/20201/17/20201/17/2020 10:21:55 AMAPASS
Please call Tim at ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 2 20lb gas pressure tests ok
MEC20-00240 Rough-in1/16/20201/17/20201/17/2020 8:52:24 AMAFAIL
Call Jason with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
- dryer vent needs nail plate
- two mini split heads need condensate ran in min 3/4" pvc
MEC20-00240 Pressure Test1/16/20201/17/20201/17/2020 8:50:52 AMAPASS
Call Jason with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
- 20lb gas pressure test ok
- tagged meter location
MEC19-03954 Final1/16/20201/17/20201/17/2020 8:06:27 AMAPASS
Electrical permit tied in now. Per Jack okay to pass. Phone #: ###-#### Inspection requested via web by Nicole Smith
- final ok
MEC19-02797 Mec-Aging Inspection1/17/20201/17/20201/17/2020 8:06:06 AM FAIL
WIP
Will need to see final connection of high pressure gas line with gas regs installed per code. Schedule inspection when work is finished.
MEC19-02814 Mec-Aging Inspection1/17/20201/17/20201/17/2020 8:04:46 AM FAIL
Fail need to see electrical permit issued for A/C
MEC19-02815 Mec-Aging Inspection1/17/20201/17/20201/17/2020 8:04:24 AM FAIL
Fail need to see electrical permit issued for A/C
MEC20-00220 Final1/16/20201/17/20201/17/2020 6:43:50 AMACANC
Phone #: ###-#### >> Inspection requested via web by SOPHIA FLEMING Inspection cancelled from web by: SOPHIA FLEMING
MEC19-05758 Rough-in1/16/20201/17/20201/16/2020 3:36:33 PMACANC
Builder ###-####
HVAC ###-#### Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks