Inspections for the day of: Wednesday, January 30, 2019.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04425 Final1/30/20191/30/20191/30/2019 3:59:42 PMPPASS
PLEASE CALL STAN THE PROPERTY MANAGER WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery
- final ok
- no card onsite to sign
MEC19-00298 Final1/29/20191/30/20191/30/2019 3:42:55 PMPNH
Please call Mike at ###-#### on the way so he can make sure he is home. He will be home until 3 pm, if it is after 3pm we will have to reschedule. Please call Brett with any questions on inspection ###-#### Phone #: ###-#### Inspection requested via web by Brett Shannon
- no access to home left notice on front door
MEC19-00268 Rough-in1/30/20191/30/20191/30/2019 2:46:11 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
- Man J doesn't match the equipment thats installed
- dryer vent ok
- line set support ok
MEC18-05670 Final1/30/20191/30/20191/30/2019 2:44:01 PMPPASS
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak
- final ok
MEC18-05827 Final1/29/20191/30/20191/30/2019 2:01:28 PMPPASS
Please call Ted, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- final ok
- signed card for occ on 110
MEC18-05836 Final1/29/20191/30/20191/30/2019 1:36:13 PMPPASS
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
- final ok
MEC19-00427 Pressure Test1/29/20191/30/20191/30/2019 11:25:22 AMAFAIL
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
- 5lb flue test ok
- 20lb gas pressure test fail gauge was under 20lb
MEC19-00427 Rough-in1/29/20191/30/20191/30/2019 11:24:48 AMAFAIL
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
- R/I ok
- 20lb pressure test fail gauge was under 20lb
MEC19-00414 Rough-in1/29/20191/30/20191/30/2019 11:03:37 AMAFAIL
Duct/Vent Modifications Phone #: ###-#### Inspection requested via web by Julie McMillan
- range vent needs a backdraft damper installed at termination
MEC16-05348 Mec-Request for Extension1/29/20191/30/20191/30/2019 10:40:46 AMPPASS
This inspection is for an extension to the permit. I have not completed the project, but it is moving forward. If you would like to come in to see the progress, please call me at ###-#### and give me about 15 minutes to rush home from work to let you in. Thanks! Phone #: ###-#### Inspection requested via web by Joshua Fusselman
- extension request ok
MEC19-00430 Rough-in1/29/20191/30/20191/30/2019 10:40:00 AMANR
Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP
- two exhaust fans need ducting finished
- need to add duct work to permit for the return air that was changed
- also need to see a 5lb flue test performed on furnace flue
- linesets and condensate lines ok
MEC18-03082 Rough-in1/28/20191/30/20191/30/2019 10:07:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
- R/I ok
MEC18-03082 Pressure Test1/28/20191/30/20191/30/2019 10:06:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
- 20lb gas pressure test ok
- tagged meter
MEC18-04130 Final1/29/20191/30/20191/30/2019 9:43:57 AMAFAIL
CODE 67801 Phone #: ###-#### Inspection requested via web by Monica Lindsay
- need to access to roof for inspecting the A/C
- condensate drain needs to be approved material pvc cpvc or other and needs to be a min of 3/4" in size. pump can be use to achieve grade but then needs to turn into approved material
MEC18-04049 Final1/30/20191/30/20191/30/2019 8:43:48 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Dan Otero Inspection cancelled from web by: Dan Otero
MEC19-00298 Final1/29/20191/30/20191/29/2019 2:23:09 PMPCANC
Please call the Mike at ###-#### on the way so he will be home when you arrive Phone #: ###-#### >> Inspection requested via web by Brett Shannon Inspection cancelled from web by: Brett Shannon
MEC16-05348 Conference1/29/20191/30/20191/29/2019 1:14:37 PMPCANC
This inspection is for an extension to the permit. I have not completed the project, but it is moving forward. If you would like to come in to see the progress, please call me at ###-#### and give me about 15 minutes to rush home from work to let you in. Thanks! Phone #: ###-#### >> Inspection requested via web by Joshua Fusselman Inspection cancelled from web by: Joshua Fusselman