Inspections for the day of: Friday, October 11, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04313 Final10/11/201910/11/201910/11/2019 3:24:20 PMPFAIL
Unit number is #18 Inspection requested via web by Margie Rowe
- electric furnace ok
- H/P needs locking caps installed on all service ports
MEC19-04041 Final10/4/201910/11/201910/11/2019 3:08:45 PMPNH
Please inspect after 1 PM. Fauzia Aziz ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- no access to home left notice on front door
MEC19-04427 Rough-in10/10/201910/11/201910/11/2019 3:03:37 PMAPART
Phone #: ###-#### Inspection requested via web by Kim Evans
- need Man J onsite
- furnace is located in a bathroom closet using combustion air from bathroom. need self closing door and all combustion air brought from outside
- need to add bathroom exhaust to permit
- this is a partial R/I so walls and ceiling in addition can be insulated and covered. all corrections still need made and R/I inspection scheduled when ready
MEC19-04483 Final10/9/201910/11/201910/11/2019 2:41:33 PMPFAIL
PLEASE CALL HOMEOWNER JUAN WHEN 20-30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery
-furnace coil co ok
- A/C needs locking caps installed on service ports
MEC19-04315 Final10/11/201910/11/201910/11/2019 2:13:55 PMPFAIL
Inspection requested via web by Margie Rowe
- not sure what house this inspection is for. Need unit number
MEC19-04325 Rough-in10/10/201910/11/201910/11/2019 1:57:00 PMPPART
sealer inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen
- partial duct seal inspection ok for insulation
MEC19-01592 Final10/11/201910/11/201910/11/2019 1:20:38 PMPPASS
Mechanical Gas Fireplace Final Inspection. Please contact home owner Dane @ ###-#### when heading there. Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace final ok
MEC19-04097 Rough-in10/11/201910/11/201910/11/2019 1:01:20 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
- Man J onsite was for a house in meridian
MEC19-03476 Final10/10/201910/11/201910/11/2019 11:47:09 AMAPASS
Mechanical Gas Fireplace Final Inspection. manual is in kitchen drawer right of stove. Garage Code: 5674 or 9378 Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace final ok
MEC19-04392 Rough-in10/10/201910/11/201910/11/2019 11:26:38 AMAPASS
Inspection requested via web by Margie Rowe
- final ok
MEC19-04442 Final10/7/201910/11/201910/11/2019 10:35:19 AMAFAIL
Homeowner Daniel Grimm ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- secondary drain needs a wet switch installed
- condensate needs repaired it was leaking on floor in basement
MEC19-04267 Final10/10/201910/11/201910/11/2019 9:23:06 AMAFAIL
Landlord would like to meet you at rental #101 about 9:30-10. Please call Rang prior to inspection to meet you. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace coil co ok
- A/C needs locking caps installed on service ports
MEC19-03689 Final10/10/201910/11/201910/11/2019 9:21:56 AMAPASS
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE

- final ok
MEC19-03763 Final10/10/201910/11/201910/11/2019 8:46:39 AMANR
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- Momentum needs to finish filling out information sticker
- trim is not complete
- where line set penetrates house siding is missing
MEC19-01140 Mec-Aging Inspection10/11/201910/11/201910/11/2019 8:02:28 AM FAIL
Permit has not been active since being issued on 3-20-19. Schedule pressure test on gas line with owner. Permit will expire at the next mechanical aging inspection if not active
MEC18-05742 Mec-Aging Inspection10/11/201910/11/201910/11/2019 7:58:52 AM PASS
Doc Permit Expired ok
MEC18-05742 DOC - Permit Expired10/11/201910/11/201910/11/2019 7:58:20 AMAPASS
Doc Permit Expired ok permit not active
MEC18-03847 Mec-Aging Inspection10/11/201910/11/201910/11/2019 7:57:32 AM PASS
Doc Permit Expired ok
MEC18-03847 DOC - Permit Expired10/11/201910/11/201910/11/2019 7:57:08 AMAPASS
Doc Permit Expired ok permit not active
MEC19-04325 Rough-in10/10/201910/11/201910/10/2019 9:58:43 AMACANC
sealer inspection Phone #: ###-#### >> Inspection requested via web by Brandon Sorensen Inspection cancelled from web by: Brandon Sorensen