MEC19-04818
| Final | 10/24/2019 | 10/24/2019 | 10/24/2019 1:19:20 PM | P | PASS |
|
|
Ryan ###-#### Will meet you on site Phone #: ###-#### Inspection requested via web by John Bertram - final ok
|
MEC19-04818
| Rough-in | 10/24/2019 | 10/24/2019 | 10/24/2019 1:19:06 PM | P | PASS |
|
|
Ryan ###-#### Will meet you on site Phone #: ###-#### Inspection requested via web by John Bertram - dyrer vent and 2 exhaust fans R/I ok
|
MEC19-04797
| Final | 10/23/2019 | 10/24/2019 | 10/24/2019 12:59:00 PM | P | PASS |
|
|
Please call Dave on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - furnace only co ok
|
MEC19-04771
| Pressure Test | 10/24/2019 | 10/24/2019 | 10/24/2019 12:04:45 PM | P | FAIL |
|
|
can you call Tom at the number above, should there be any issues?
Nat Phone #: ###-#### Inspection requested via web by Nat Golden - 20lb gas pressure test ok - gas line penetration needs protective tape installed. Will tag meter when corrections are made
|
MEC19-04323
| Final | 10/23/2019 | 10/24/2019 | 10/24/2019 12:03:17 PM | P | FAIL |
|
|
BRECK IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - all gas line penetrations need sealed
|
MEC19-04497
| Final | 10/17/2019 | 10/24/2019 | 10/24/2019 12:00:23 PM | P | FAIL |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 1:30 . Contact for Right Now is Mary ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok - 5lb flue pressure test fail
|
MEC19-03896
| DOC - Permit Finaled | 10/24/2019 | 10/24/2019 | 10/24/2019 11:28:11 AM | P | PASS |
|
|
locking caps on A/C ok
|
MEC19-04602
| Rough-in | 10/23/2019 | 10/24/2019 | 10/24/2019 10:55:10 AM | A | FAIL |
|
|
Call to meet you Phone #: ###-#### Inspection requested via web by Rene Neumeyer - gas pressure test fail - gas shut off valve is positioned where it can't be opened 100% re position valve
|
MEC19-04602
| Pressure Test | 10/23/2019 | 10/24/2019 | 10/24/2019 10:54:18 AM | A | FAIL |
|
|
Call to meet you Phone #: ###-#### Inspection requested via web by Rene Neumeyer - 20lb gas pressure test fail gauge under 20lb - make sure gas test is either disconnected from live gas or a double valve open ended tee is installed between new gas line and live gas
|
MEC19-04808
| Pressure Test | 10/23/2019 | 10/24/2019 | 10/24/2019 10:28:21 AM | A | FAIL |
|
|
MOVED GAS LINE NEED PRESSURE TEST Phone #: ###-#### Inspection requested via web by Andrea Creek - gas line in shop was under 20lb - under ground gas line 20lb ok backfill ok - need to verify gas meter is sized properly for new load
|
MEC19-04789
| Final | 10/23/2019 | 10/24/2019 | 10/24/2019 10:07:05 AM | A | FAIL |
|
|
Replace existing 4 ton RTU with new 4 ton Rtu with same specs. Phone #: ###-#### Inspection requested via web by jeremy wanders - need weather tight conduit installed on RTU
|
MEC19-04780
| Rough-in | 10/23/2019 | 10/24/2019 | 10/24/2019 9:46:54 AM | A | FAIL |
|
|
Call Jason @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire - need stamped Man J onsite - supply plenum in crawl needs insulated - cant find fresh air duct due to sheet rock being installed before Mechanical R/I passed
|
MEC19-04780
| Pressure Test | 10/23/2019 | 10/24/2019 | 10/24/2019 9:45:35 AM | A | PASS |
|
|
Call Jason @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire 2- 5lb flue pressure tests ok - 20lb gas pressure test ok - tagged meter location
|
MEC19-04289
| Rough-in | 10/23/2019 | 10/24/2019 | 10/24/2019 9:15:20 AM | A | FAIL |
|
|
Rough In Inspection of Dampers - someone will be on site Phone #: ###-#### Inspection requested via web by Beka Hereau - duct work ok - still need proper installation instructions for round fire dampers. All angles need removed to check clearances. remove fire caulk on dampers unless instructions say to do so. Each fire damper will also need an access door installed. - condensates for units ok - exhaust side of radiant heaters needs sealed with high temp sealer and need to check clearances on vent throughn roof
|
MEC18-04255
| Mec-Aging Inspection | 10/24/2019 | 10/24/2019 | 10/24/2019 8:05:55 AM | | PASS |
|
|
Doc Permit Expired ok
|
MEC18-04255
| DOC - Permit Expired | 10/24/2019 | 10/24/2019 | 10/24/2019 8:05:41 AM | A | PASS |
|
|
Doc Permit Expired ok permit not active
|
MEC18-05889
| Mec-Aging Inspection | 10/24/2019 | 10/24/2019 | 10/24/2019 8:05:11 AM | | PASS |
|
|
Doc Permit Expired ok
|
MEC18-05889
| DOC - Permit Expired | 10/24/2019 | 10/24/2019 | 10/24/2019 8:04:55 AM | A | PASS |
|
|
Doc Permit Expired ok permit not active
|
MEC19-01309
| Mec-Aging Inspection | 10/24/2019 | 10/24/2019 | 10/24/2019 8:04:18 AM | | DONE |
|
|
WIP
|
MEC19-04420
| Rough-in | 10/23/2019 | 10/24/2019 | 10/23/2019 4:01:56 PM | A | CANC |
|
|
Relocated Both vents for water heater and furnace to other part of roof Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
MEC19-04420
| Pressure Test | 10/23/2019 | 10/24/2019 | 10/23/2019 4:01:54 PM | A | CANC |
|
|
Relocated Both vents for water heater and furnace to other part of roof Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|