Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05294 Rough-in11/25/201911/25/201911/25/2019 4:15:45 PMPFAIL
Phone #: 2088718789 >> Inspection requested via mobile web by Albert
- need approved man j onsite
MEC19-05293 Rough-in11/25/201911/25/201911/25/2019 4:14:32 PMPFAIL
Phone #: 2088718789 >> Inspection requested via mobile web by Albert
- need approved man j onsite
MEC19-05293 Pressure Test11/25/201911/25/201911/25/2019 4:13:45 PMPPASS
Phone #: 2088718789 >> Inspection requested via mobile web by Albert
- 20lb gas pressure test ok
- tagged meter
MEC19-05294 Pressure Test11/25/201911/25/201911/25/2019 4:12:52 PMPPASS
Phone #: 2088718789 >> Inspection requested via mobile web by Albert
- 20lb gas pressure test ok
- tagged meter
MEC19-04324 Rough-in11/25/201911/25/201911/25/2019 3:10:35 PMPFAIL
Please contact Glen with any questions. ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Yvonne Bowman
- exhaust fan ducting in bathroom needs sealed for cover of ceiling
MEC19-03972 Final11/25/201911/25/201911/25/2019 3:09:47 PMPFAIL
Dale Phone #: ###-####
- gas line penetrations needs sealed
- line set needs UV protection
no access to home all doors locked
MEC19-04404 Rough-in11/25/201911/25/201911/25/2019 2:29:15 PMPPASS
Mark Phone #: ###-####
MEC19-01757 Final11/25/201911/25/201911/25/2019 2:07:02 PMPPART
Phone #: ###-#### Inspection requested via web by RaChelle Frisbee
- TAB report ok. Will sign occ card once corrections are made and two other mech permits from others are finaled
- all equipment needs set in its place and hood should hang not less than 6" beyond edge of equipment. one piece of equipment is outside of hoods edge.
- both hoods need grease reservoirs installed in hood
MEC19-03990 Rough-in11/25/201911/25/201911/25/2019 1:24:29 PMPPASS
cover for second floor - Leroy Phone #: ###-#### Inspection requested via web by Brandon Sorensen
- 2nd floor R/I ceiling cover ok
MEC19-05090 Final11/19/201911/25/201911/25/2019 1:23:03 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
MEC19-05286 Final11/25/201911/25/201911/25/2019 1:14:02 PMPPASS
Ed Phone #: ###-####
- furnace only co ok
MEC19-04325 Final11/22/201911/25/201911/25/2019 12:06:02 PMAPASS
final ok
- signed occ card
MEC19-04414 Final11/24/201911/25/201911/25/2019 11:18:39 AMAFAIL
Garage code is 2468. Air balance report is in the drain in the garage door
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- need duct blast report onsite
MEC19-04664 Rough-in11/21/201911/25/201911/25/2019 11:18:16 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart
- water heater flue has screws penetrating inner liner. Replace pipe
- fireplace needs wood shavings cleaned off top of fireplace
MEC19-04664 Pressure Test11/21/201911/25/201911/25/2019 11:17:13 AMAPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
- 20lb gas pressure test ok
- tagged meter
MEC19-04611 Rough-in11/22/201911/25/201911/25/2019 11:16:50 AMAPASS
ManJ now on Site Phone #: ###-#### Inspection requested via web by Randy Hart
- R/I ok
MEC19-04613 Rough-in11/22/201911/25/201911/25/2019 11:16:35 AMAPASS
ManJ now on site Phone #: ###-#### Inspection requested via web by Randy Hart
- R/I ok
MEC19-04838 Final11/18/201911/25/201911/25/2019 10:00:30 AMAPASS
PHONE: ###-#### (CASEY COOK) Phone #: ###-#### Inspection requested via web by Mike Almanza
- fireplace final ok
MEC19-05269 Final11/21/201911/25/201911/25/2019 9:43:11 AMAPASS
Tenant is Jeff ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- air handler coil HP ok
MEC19-05322 Final11/22/201911/25/201911/25/2019 9:33:08 AMAFAIL
Replace existing 4 ton and 5 Ton RTU with new RTU of the same specs. Economizers installed on new RTU. Phone #: ###-#### Inspection requested via web by jeremy wanders
- both RTU's need condensates installed
- RTU on west side needs gas line supported/shut off valve and test port installed before regulator
MEC19-05116 Rough-in11/22/201911/25/201911/25/2019 9:19:09 AMAPASS
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace R/I ok
MEC19-05286 Pressure Test11/21/201911/25/201911/25/2019 8:57:18 AMAPASS
Ed Phone #: ###-####
- 5lb flue pressure test
- 20lb gas pressure test ok
- tagged meter
MEC19-01879 Mec-Aging Inspection11/25/201911/25/201911/25/2019 8:16:03 AM FAIL
Permit has failed due to not being active since issued date of 5-7-19. No inspections have been performed on this site. Schedule an inspection with the homeowner if work is finished.
MEC19-01883 Mec-Aging Inspection11/25/201911/25/201911/25/2019 8:14:14 AM FAIL
Permit has failed due to not being active since being issued on 5-7-19. No inspections have been performed on this site. Schedule an inspection with the homeowners if work is finished.
MEC19-01910 Mec-Aging Inspection11/25/201911/25/201911/25/2019 8:12:39 AM PASS
Doc Permit Finaled ok
MEC19-01910 DOC - Permit Finaled11/25/201911/25/201911/25/2019 8:12:24 AMAPASS
Doc Permit Finaled Ok
MEC19-01886 Mec-Aging Inspection11/25/201911/25/201911/25/2019 8:11:47 AM FAIL
Permit has failed due to not be active since being issued on 5-7-19. Schedule inspection if work is finished
MEC19-04838 Final11/18/201911/25/201911/18/2019 9:29:46 AMACANC
PHONE: ###-#### (CASEY COOK) Phone #: ###-#### >> Inspection requested via web by Mike Almanza Inspection cancelled from web by: Mike Almanza