MEC18-05418
| Rough-in | 12/11/2018 | 12/12/2018 | 12/12/2018 3:55:42 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - water heater flue needs 1" clearances - insulation sheild needs needs to maintain 1" clearances - need Man J approved and onsite - combustion air for mec room
|
MEC18-05418
| Pressure Test | 12/11/2018 | 12/12/2018 | 12/12/2018 3:54:19 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - gauge under 20lb
|
MEC18-05852
| Rough-in | 12/11/2018 | 12/12/2018 | 12/12/2018 3:06:17 PM | P | FAIL |
|
|
garage code in case no one is there: 2102 Phone #: ###-#### Inspection requested via web by Michael Stimpson - 1" clearances on water heater b vent in several locations. Also 1" clearances once sheet rock is installed - 1 exhaust fan upstairs is not finished and connection needs sealed - need to see a 5lb flue pressure test before ceiling cover - dryer vent needs to be independent. can't common vent bathroom exhaust and dryer together
|
MEC18-05908
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 2:54:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace only co ok
|
MEC18-05934
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 2:37:16 PM | P | PASS |
|
|
Please contact Maddie prior to arrival ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - a/c coil co ok
|
MEC18-04683
| Rough-in | 12/12/2018 | 12/12/2018 | 12/12/2018 2:18:55 PM | P | PASS |
|
|
3 FLOOR Phone #: ###-#### Inspection requested via web by Oleg Chervak - R/I for 2nd floor and 3rd floor ok buidling D
|
MEC18-05932
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 1:43:13 PM | P | NR |
|
|
Please call Josh prior to arrival ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
MEC18-02618
| Final | 12/12/2018 | 12/12/2018 | 12/12/2018 1:42:49 PM | P | FAIL |
|
|
Larren ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - need to prove 1/2" gas line is big enough for furnace - need to flue test
|
MEC18-05681
| Rough-in | 12/12/2018 | 12/12/2018 | 12/12/2018 1:06:27 PM | P | PASS |
|
|
Partial above grid, duct work is wrapped Inspection requested via web by Floyd Floyd Peek - duct work insulation ok
|
MEC18-05773
| Rough-in | 12/12/2018 | 12/12/2018 | 12/12/2018 1:06:09 PM | P | PASS |
|
|
Partial above grid, duct work is wrapped Inspection requested via web by Floyd Floyd Peek - duct work insulation ok
|
MEC18-05848
| Final | 12/6/2018 | 12/12/2018 | 12/12/2018 10:00:39 AM | A | PASS |
|
|
Please call Ann at ###-#### when in route Phone #: ###-#### Inspection requested via web by Sabrina DeHority- furnace only co ok
|
MEC18-05889
| Final | 12/7/2018 | 12/12/2018 | 12/12/2018 10:00:06 AM | A | CANC |
|
|
Please call William at ###-#### when in route. Phone #: ###-#### Inspection requested via web by Sabrina DeHority - homeowner said he could not make it to scheduled inspection
|
MEC18-05924
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 9:43:35 AM | A | PASS |
|
|
please call Tony 1 hour before Phone #: ###-####
|
MEC18-05355
| Final | 12/5/2018 | 12/12/2018 | 12/12/2018 9:28:41 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone - need co detector in hallway near bedrooms - furnace ac coil co ok
|
MEC18-04428
| Final | 12/11/2018 | 12/12/2018 | 12/12/2018 9:11:02 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - fireplace final ok
|
MEC18-02236
| Pressure Test | 12/11/2018 | 12/12/2018 | 12/12/2018 9:00:23 AM | A | PASS |
|
|
Call prior to going Phone #: 2088718789 >> Inspection requested via mobile web by Albert - 60lb gas pressure test ok
|
MEC18-05816
| Rough-in | 12/11/2018 | 12/12/2018 | 12/12/2018 8:50:20 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero - fireplace R/I ok
|
MEC17-05578
| Mec-Aging Inspection | 12/12/2018 | 12/12/2018 | 12/12/2018 8:08:58 AM | | DONE |
|
|
called western about mechanical aging permit
|
MEC18-01212
| Mec-Aging Inspection | 12/12/2018 | 12/12/2018 | 12/12/2018 8:00:15 AM | | FAIL |
|
|
- need to schedule inspection
|
MEC18-04453
| Final | 12/10/2018 | 12/12/2018 | 12/11/2018 9:27:35 AM | A | CANC |
|
|
HP-39 replacement. Customer contact is Mike Cano: ###-####. Can call tech if you need access: ###-#### Phone #: ###-#### >> Inspection requested via web by Melissa Skinner Inspection cancelled from web by: Melissa Skinner
|