Inspections for the day of: Friday, December 14, 2018.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-05918 Final12/11/201812/14/201812/14/2018 3:56:04 PMPPASS
Please inspect after 12:30. Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace only co ok
MEC18-05418 Pressure Test12/13/201812/14/201812/14/2018 3:17:37 PMPPASS
Inspection requested via web by Gary Reeves
- 20lb gas pressure test ok
- 5lb flue pressure test ok
MEC18-05418 Rough-in12/13/201812/14/201812/14/2018 3:16:59 PMPPASS
Inspection requested via web by Gary Reeves
- R/I ok
MEC18-05232 Final12/14/201812/14/201812/14/2018 3:00:36 PMPFAIL
Phone #: ###-#### Inspection requested via web by Joseph Profitt
- condensate line needs support
- furnace flue needs 1" clearances to roof materials
MEC18-05946 Final12/13/201812/14/201812/14/2018 2:49:02 PMPFAIL
PLEASE CALL HOMEOWNER JAMI WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery
- needs a 5lb flue test
- old 80% flue needs an end cap installed on Y
MEC18-02618 Final12/14/201812/14/201812/14/2018 2:22:15 PMPPASS
Inspector aware of situation and is communicating with Tyrel Inspection requested via web by Arielle Hendricks
- 5lb flue pressure test
-gas piping size for furnace ok
MIS18-00463 MEC-Final12/14/201812/14/201812/14/2018 2:11:31 PMPFAIL
Leticia Phone #: ###-####
- need grease pans installed on all hoods
- need to tether one peice of equipment and two others need wheels removed if no tethers are going to be installed
- filter needs replaced in one hood due to damage
MEC18-04150 Final12/13/201812/14/201812/14/2018 1:17:30 PMPCANC
Dale Phone #: ###-####
- not ready did not have the 5lb flue gauge ready rescheduled for monday morning
MEC18-05960 Final12/13/201812/14/201812/14/2018 1:16:11 PMPPASS
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace only co ok
MEC18-04347 Final12/13/201812/14/201812/14/2018 10:56:49 AMAPASS
0807 Phone #: ###-#### Inspection requested via web by Gary Reeves
- final ok
MEC18-04695 Final12/13/201812/14/201812/14/2018 10:51:54 AMAPASS
garage code: 2639 Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace final ok
MEC18-04741 Final12/13/201812/14/201812/14/2018 10:51:38 AMAPASS
Garage code: 2639 Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace final ok
MEC18-05739 Final12/11/201812/14/201812/14/2018 10:37:18 AMAPASS
Please inspect after 9 AM. Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace only co ok
MEC18-05964 Pressure Test12/13/201812/14/201812/14/2018 10:10:48 AMAFAIL
Lindsey Kinghorn Phone #: ###-#### Inspection requested via web by Jamee Shoecraft
- 20 lb gas line to fireplace ok
- 20lb gas line to range was under 20 lb
MEC18-05763 Pressure Test12/13/201812/14/201812/14/2018 9:50:37 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
- 20lb gas pressure test ok on both north and south unit
MEC18-05763 Rough-in12/13/201812/14/201812/14/2018 9:50:10 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
- R/I ok on both south and north unit
MEC18-05953 Rough-in12/13/201812/14/201812/14/2018 9:32:56 AMAFAIL
building B exhausts

- exhaust ducts needs sealed in several places
- line set insulation needs fixed in several places
- line sets need supported
MEC18-05290 Rough-in12/13/201812/14/201812/14/2018 8:50:09 AMAFAIL
Phone #: ###-#### Inspection requested via web by Terek Worley
- two range hoods will be under 400 cfm each hood has a max 190 cfm
- Man J doesnt match what is installed in home. - the Man J shows gas furnace and there is a electric furnace installed
MEC18-05804 Final12/11/201812/14/201812/14/2018 8:27:26 AMANH
If possible, please call Lori one hour before at ###-####. Thank you. Phone #: ###-#### Inspection requested via web by James Cox
- No access to home called number in notes and no anwser left notice on front door
MEC17-05636 Mec-Aging Inspection12/14/201812/14/201812/14/2018 8:20:24 AM DONE
called and left homeowner voicemail regarding mec aging permit
MEC17-03083 Mec-Aging Inspection12/14/201812/14/201812/14/2018 8:08:27 AM DONE
called contractor and left message