Inspections for the day of: Tuesday, December 18, 2018.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-05675 Final12/18/201812/18/201812/18/2018 4:00:02 PMPPASS
Please call tenant Frank when in route--Will be home after 1PM ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
- furnace only co ok
MEC18-05490 Final12/17/201812/18/201812/18/2018 3:30:43 PMPNH
Please inspect after 2:30. Phone #: ###-#### Inspection requested via web by Mary LaFayette
- no access to home left notice on front door
MEC18-06004 Final12/17/201812/18/201812/18/2018 3:18:28 PMPFAIL
if questions call Jared @ ###-#### or Jerry @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
- 20lb gas pressure test fail gauge was stuck at 12lbs- need to see gas flex supported in crawl
-
MEC18-04154 Final12/18/201812/18/201812/18/2018 2:37:34 PMPFAIL
THOMAS IS CONTACT PERSON ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- need Man J performed and stamped onsite
-need balance report and duct blast onsite
- need a level platform in front of furnace in attic at least 30"
- condensate needs support on outside of house
- secondary drain and pan needs a wet switch
- gas line in attic needs support and a sediment trap
- dryer vent did not have nail plates in photos that were provided
- dryer vent cap needs to be an approved cap with no screens and a backdrft damper
- need to see exhaust fans duct work
- supply duct work needs balance dampers
- water heater flue needs 1" clearances
- this inspection should have been a R/I

MEC18-05211 Final12/17/201812/18/201812/18/2018 2:07:44 PMPNH
Gate on S side of house, come around back. Dog will bark, but is a sweetheart. Of course, everyone says that.. Phone #: ###-#### Inspection requested via web by Michael McDonald
- rescheduled with homeowner cause he wasnt home to let me in
MEC18-06010 Pressure Test12/17/201812/18/201812/18/2018 1:27:45 PMPPASS
PLEASE CALL OUR LEAD INSTALLER BRAD WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery
- 20lb gas pressure test ok
- tagged meter bar
MEC18-05773 Final12/18/201812/18/201812/18/2018 1:06:56 PMPPASS
Inspection requested via web by Floyd Floyd Peek
- final ok
- signed card
MEC17-05457 Rough-in12/17/201812/18/201812/18/2018 11:07:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Nicholas Paige
-100lb hydronics test ok
MEC18-05548 Rough-in12/17/201812/18/201812/18/2018 10:42:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace R/I ok
MEC18-05641 Final12/17/201812/18/201812/18/2018 9:53:57 AMAPASS
Please call Steve the owner when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd
- furnace ac coil co ok
MEC18-05998 Pressure Test12/17/201812/18/201812/18/2018 8:56:08 AMAPASS
please call homeowner Cory when 30 mins in route but gas line is on pressure and on outside of home if he doesnt answer Phone #: ###-#### Inspection requested via web by Rick Montgomery
- 20lb gas pressure test ok- tagged meter bar
MEC17-04486 Mec-Aging Inspection12/18/201812/18/201812/18/2018 8:30:52 AM DONE
called contractor about mec aging permit. Schedule inspection with homeowner
MEC17-03119 Mec-Aging Inspection12/18/201812/18/201812/18/2018 8:10:30 AM DONE
called and talked to sarah and gave information about mec aging permit. need to schedule inspection
MEC17-04511 Mec-Aging Inspection12/18/201812/18/201812/18/2018 8:03:00 AM PASS
MEC17-04511 DOC - Permit Expired12/18/201812/18/201812/18/2018 8:02:52 AMPPASS
MEC18-06010 Final12/17/201812/18/201812/17/2018 4:14:08 PMPCANC
PLEASE CALL OUR LEAD INSTALLER BRAD WHEN 30 MINS IN ROUTE Phone #: ###-#### >> Inspection requested via web by Rick Montgomery Inspection cancelled from web by: Rick Montgomery